Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 12 de 12
Filter
1.
Bioresour Technol ; 406: 130929, 2024 Jun 03.
Article in English | MEDLINE | ID: mdl-38838832

ABSTRACT

Polyethylene terephthalate (PET) has caused significant pollution issues. Compared to chemical degradation with high energy consumption and cost, enzymatic degradation offers a sustainable solution for PET waste recycling. However, the hydrolytic activity of current PET hydrolases still requires improvement. In this study, a cross-correlation-based accumulated mutagenesis (CAM) strategy was developed to enhance the hydrolysis activity. By mitigating epistatic effect and combinational mutations, we achieved a highly active variant LCC-YGA (H183Y/L124G/S29A) with 2.1-fold hydrolytic activity on amorphous PET films of LCC-ICCG. Conformational analysis elucidated how the introduction of distal mutations enhanced activity. The dynamic correlation among different regions facilitated a synergistic effect, enhancing binding pocket flexibility through remote interactions. Totally, this work offers novel insights and methods for PET hydrolases engineering and provides an efficient enzyme for PET degradation and recycling.

2.
Zhongguo Yi Liao Qi Xie Za Zhi ; 47(6): 702-705, 2023 Nov 30.
Article in Chinese | MEDLINE | ID: mdl-38086733

ABSTRACT

OBJECTIVE: To analyze the medical equipment operation data of 44 clinical departments in the hospital from three aspects: materials and consumables, operation and maintenance depreciation, and operation management. METHODS: To formulate the evaluation standards and scoring criteria for the operation indicators, the lowest score is 0 points, and the highest score is 5 points. Based on the operation indicators of medical equipment, establish a hierarchical structure model, determine the criterion layer and sub-criteria layer, construct a judgment matrix, normalize it, and calculate the weight coefficient. RESULTS: Count equipment operation data in 2021 and 2022. Score according to the assessment standards, assign weights through the analytic hierarchy process, calculate the total score and sort, and making a special analysis on the top 10 departments and departments with a score below 4 points, and formulate a rectification plan. CONCLUSIONS: The establishment of index assessment standards and the weight distribution of AHP can effectively enhance the control of equipment operating costs.


Subject(s)
Analytic Hierarchy Process , Rationalization , Surgical Equipment , Reference Standards , Cost Control
3.
BMC Health Serv Res ; 22(1): 429, 2022 Apr 01.
Article in English | MEDLINE | ID: mdl-35361206

ABSTRACT

BACKGROUND: Medical ultrasound device has been more and more widely used in the hospital and Its safety risk is significantly increased when failures occur. However, there is a lack of quantitative risk assessments of different types of failure modes for medical ultrasound device. This study utilizes a failure mode, effect and criticality analysis (FMECA) approach for quantitative risk evaluation of different failure modes for ultrasound devices. METHODS: The 4216 medical ultrasound device failure records at various hospitals were investigated. A failure mode and effect analysis method was developed for the quantitative evaluation of the risks of different failure modes. Visual correlation analysis was conducted for all categories to identify the causes of various failure modes. Based on the severity, occurrence and detectability of the failure causes determined, the risk priority number (RPN) for each failure mode was back-calculated through the obtained tracking diagram. RESULTS: The failure modes of unclear images, unable to power on and dark shadows on an image had the highest RPNs. One failure mode could be caused by various factors, and the failure location was not necessarily related to the cause of the failure. CONCLUSIONS: This quantitative approach more accurately evaluated the risks of different failure modes, and the results of the corresponding analysis of failure modes and causes could support the rapid determination of the causes of failures in clinical practice.


Subject(s)
Hospitals , Equipment Failure , Humans , Risk Assessment
4.
Bioresour Technol ; 302: 122844, 2020 Apr.
Article in English | MEDLINE | ID: mdl-32006927

ABSTRACT

Cadaverine is the monomer of bio-based nylons polyamide 5.4, 5.6 and 5.10. In this study, a litre-scale integrated strategy was developed for high-efficiency and low-cost production of cadaverine using an engineered Escherichia coli. Firstly, the engineered strain BL21-Pcad-CadA induced by cheap l-lysine-HCl instead of IPTG was constructed. Then the permeabilized cells were served as the biocatalyst for the production of cadaverine, because the enhanced permeability facilitated the mass transfer of the substrate and the release of products. After the replacement of industrial materials and the solution of the scale-up permeabilization process, cadaverine concentration reached 205 g/L with the yield of 92.1% after 20 h in a 2 L bioconversion system, achieving the level of industrial production. Furthermore, the costs of industrial materials for 2 L integrated strategy ($2.78) was only 1/11 of the lab reagents ($30.88). Therefore, the proposed strategy is a promising candidate for the industrial process of cadaverine.


Subject(s)
Carboxy-Lyases , Escherichia coli , Cadaverine , Lysine
5.
Zhongguo Yi Liao Qi Xie Za Zhi ; 42(5): 332-334, 2018 Sep 30.
Article in Chinese | MEDLINE | ID: mdl-30358344

ABSTRACT

OBJECTIVE: Establish a regional cloud account of hospital medical equipment based on dynamic two-dimensional code link. METHODS: Establish a medical equipment data platform based on B/S architecture. Combined with mobile internet means such as WeChat and try the industrial 4.0 designed intelligent boxes. RESULTS: The problem of no interface transmission and integration of the regional medical equipment account information is solved. It dynamically collects equipment data, operation cost and efficiency. The real-time operation data is visualized. CONCLUSIONS: The dynamic management platform of regional medical equipment helps to standardize the management of large medical equipment and improve the utilization ratio of medical equipment. The platform provides basis of management decisions and equipment allocation for relevant departments.


Subject(s)
Cloud Computing , Equipment and Supplies , Internet
6.
Zhongguo Yi Liao Qi Xie Za Zhi ; 42(3): 228-231, 2018 May 30.
Article in Chinese | MEDLINE | ID: mdl-29885136

ABSTRACT

This study based on the technology evolution theory, S-curve and bibliometrics, verified product evolution was accompanied by the evolution and transition of a number of sub technologies. It judged MRI was in the stage of underdevelopment and a new round of technology was being developed. It was found that the value of MRI equipment in scientific research or clinical application in foreign countries was higher than that in China by comparing the literatures at home and abroad. And there was a gap between China and the world scientific center in the independent R&D capability. The study verified the applicability of the technical evolution theory and the evaluation empirical laws in the medical devices evaluation, and explored the operability of the assessment tools. This paper not only provided a reference for equipment configuration, but also showed the gaps of key technologies in home and abroad and provided a reference for upgrading China's independent innovation and industrial technology.


Subject(s)
Magnetic Resonance Imaging/instrumentation , China , Industry , Technology/trends
7.
Zhongguo Yi Liao Qi Xie Za Zhi ; 42(1): 46-48, 2018 Jan 30.
Article in Chinese | MEDLINE | ID: mdl-29862746

ABSTRACT

This paper reviews the principle and clinical application of hydrosurgery system, including the burn debridement, diabetic foot wounds debridement and other trauma debridement. Meanwhile, this paper introduces the development direction of waterjet technology. Furthermore, the safety, effectiveness and suitability can be discussed.


Subject(s)
Burns/therapy , Debridement/methods , Hydrotherapy , Foot Ulcer/therapy , Humans , Treatment Outcome , Wound Healing
8.
Zhongguo Yi Liao Qi Xie Za Zhi ; 42(2): 144-146, 2018 Feb 08.
Article in Chinese | MEDLINE | ID: mdl-29845820

ABSTRACT

This paper introduces the technical features of hydrosurgery system and evaluates it from three aspects:safety and effectiveness, economy and technology maturity. The evaluation results show that the safety and effectiveness are high, and the safety mainly involves the misuse of the system, which cause the adverse events. A large number of literatures have proved that the system is more suitable for the debridement of fine parts. It is estimated that hydrosurgery system has better economic performance, but the cost and patients' cost is also increased correspondingly. In the aspect of technology maturity assessment, this technology is a patented technology, and the number of published papers both at home and abroad is on the rise, indicating that the initial application of the technology is better and the technology is in infancy stage. Therefore, hydrosurgery system has certain advantages in all aspects. Hospitals need to allocate the equipment according to their own needs and clinical application, while a wider range of clinical trials is needed to provide evidence-based evidence for clinical applications and promotion.


Subject(s)
Debridement/instrumentation , Water Purification , Equipment and Supplies , Humans
9.
Zhongguo Yi Liao Qi Xie Za Zhi ; 40(1): 55-7, 2016 Jan.
Article in Chinese | MEDLINE | ID: mdl-27197500

ABSTRACT

The hydrogen peroxide low temperature plasma sterilization technology solved the problems of thermo-sensitive materials' disinfection and sterilization based on its development and unique characteristics. This paper introduced the researches of clinical application quality control, and showed the hydrogen peroxide low temperature plasma sterilizers were being widely used in hospitals and highly recognized. According to the clinical data and the literatures of the domestic equipment in preliminary application, it could be concluded that the technology maturity of domestic hydrogen peroxide low temperature plasma sterilizers was in a high level. The advantages of using domestic hydrogen peroxide low temperature plasma sterilizers to do disinfection and sterilization included lower cost, safer, faster and non-toxic, etc. Also the management system should be improved and the clinical staff should master the technical essentials, obey the procedures strictly, verify periodically and offer full monitoring to upgrade the quality of sterilization.


Subject(s)
Cold Temperature , Disinfection/instrumentation , Hydrogen Peroxide/chemistry , Plasma Gases/chemistry
10.
Zhongguo Yi Liao Qi Xie Za Zhi ; 37(1): 66-7, 2013 Jan.
Article in Chinese | MEDLINE | ID: mdl-23668048

ABSTRACT

In 2011, Shanghai Medical Equipment Management Quality Control Center launched the fifth after-sale service satisfaction survey for medical devices in Shanghai area. There are 8 classes medical devices involving in the survey. This paper demonstrates the investigation results of monitoring devices which are from different manufacturers.


Subject(s)
Consumer Behavior , Equipment and Supplies , Product Surveillance, Postmarketing , Quality Control
11.
Zhongguo Yi Liao Qi Xie Za Zhi ; 36(2): 93-5, 2012 Mar.
Article in Chinese | MEDLINE | ID: mdl-22737885

ABSTRACT

The quantity of medical equipment in hospital rise quickly recent year. It provides the comprehensive support to the clinical service. The maintenance of medical equipment becomes more important than before. It is necessary to study on the orientation and function of clinical engineer in medical equipment maintenance system. Refer to three grade health care system, the community doctors which is called General practitioner, play an important role as the gatekeeper of health care system to triage and cost control. The paper suggests that hospital clinical engineer should play similar role as the gatekeeper of medical equipment maintenance system which composed by hospital clinical engineer, manufacture engineer and third party engineer. The hospital clinical engineer should be responsible of guard a pass of medical equipment maintenance quality and cost control. As the gatekeeper, hospital clinical engineer should take the responsibility of "General engineer" and pay more attention to safety and health of medical equipment. The responsibility description and future transition? development of clinical engineer as "General Engineer" is discussed. More attention should be recommended to the team building of hospital clinical engineer as "General Engineer".


Subject(s)
Engineering , Equipment and Supplies, Hospital , Safety Management/organization & administration , Equipment Safety , Humans , Maintenance and Engineering, Hospital
12.
Zhongguo Yi Liao Qi Xie Za Zhi ; 36(6): 451-2, 458, 2012 Nov.
Article in Chinese | MEDLINE | ID: mdl-23461127

ABSTRACT

To improve the manufacturer's medical equipment after-sale service, the fifth Shanghai zone customer satisfaction survey was launched by the end of 2011. The DSA/X-ray equipment was setup as an independent category for the first time. From the survey we can show that the DSA/X-ray equipment's CSI is higher than last year, the customer satisfaction scores of preventive maintenance and service contract are lower than others, and CSI of local brand is lower than imported brand.


Subject(s)
Consumer Behavior , Product Surveillance, Postmarketing/statistics & numerical data , Radiography/standards , Quality Control , Radiography/instrumentation
SELECTION OF CITATIONS
SEARCH DETAIL
...