Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 20 de 21
Filter
1.
Heart Rhythm ; 2024 Apr 06.
Article in English | MEDLINE | ID: mdl-38588992

ABSTRACT

BACKGROUND: The aorta-mitral annulus conjunction (AMC) is an uncommon site of origin of focal atrial tachycardias (ATs). Hence, the electrophysiological and ablation target characteristics are poorly described. OBJECTIVE: The purpose of this study was to describe the characteristics of AMC AT in detail. METHODS: The study enrolled 650 patients with AT, 21 (3.2%) of whom had AT originating from the AMC. A comprehensive evaluation, including electrocardiography, electrophysiology study, computed tomography scan, and intracardiac echocardiography, was performed. RESULTS: The majority (90.5%) of ATs occurred spontaneously. The mean age of this group was 48.9 ± 21.6 years, with 12 being female (57.1%). Seventeen patients had a typical biphasic P wave with a prominent positive component. The earliest activation site in the right atrium was near the His bundle, with average activation -10.3 ± 6.0 ms preceding the P wave. The successful ablation targets were distributed as follows: 1 case at 9 o'clock, 6 cases at 10 o'clock, 7 cases at 11 o'clock, 6 cases at 12 o'clock, and 1 case in the left coronary cusp. The local AMC potential differed from the commonly perceived annular potential and was characterized by a large A and a small V (atrial-to-ventricular ratio > 1). The angle of encroachment on the left atrial anterior wall, compressed by the left coronary cusp, was significantly smaller in the AMC AT group than in the control group, which may have contributed to the arrhythmia substrate (141.7° ± 11.5° vs 155.2° ± 13.9°; P = .026). CONCLUSION: A new strategy for mapping AMC ATs has been introduced. The ablation target should have an atrial-to-ventricular ratio of >1.

2.
Front Cardiovasc Med ; 8: 767514, 2021.
Article in English | MEDLINE | ID: mdl-34950714

ABSTRACT

Background: The predictability and long-term outcome of the discrete pre-potential (DPP) of idiopathic ventricular arrhythmias (VAs) arising from the aortic sinuses of Valsalva (ASV) have not been fully identified. Methods: Of 687 consecutive patients undergoing ablation of outflow tract VAs, there were 105 (15.3%) patients with VAs originating from the ASV region who were included. Detailed mapping was performed within the ASV in all patients. Electrocardiographic, electrophysiological parameters, and long-term success rate were compared between patients with and without the DPPs. Results: A DPP was recorded in 67 of 105 (63.8%) patients, including 38 left sinus of Valsalva (LSV)-VAs (38/105, 36.2%) and 29 right sinus of Valsalva (RSV)-VAs (29/105, 27.6%). The patients with DPPs had wider QRS duration (152 ± 17 vs. 145 ± 14 ms, p < 0.001). The average of earliest activation time was significantly earlier in patients with DPPs (-38.6 ± 8.5 vs. -27.7 ± 5.7 ms, p < 0.001). Mean time from the first lesion to elimination of VAs was shorter in patients with DPPs (2.3 ± 2.1 s vs. 4.9 ± 1.0 s, p < 0.001). A stepwise logistic multivariable analysis identified only younger age as a significant predictor of DPP (age ≤ 35.5 years predicted DPP with 92.9% positive predictive value). During a follow-up duration of 42.5 ± 22.3 months, 63 (94.0%) patients with DPPs and 30 (78.9%) patients without DPPs remained free of recurrent VAs (p = 0.027). Conclusion: Discrete pre-potentials were observed in 63.8% of patients with VAs arising from the ASV. Ablation in patients with DPPs was associated with higher long-term success. DPPs were seen more commonly in younger (age ≤ 35.5 years) patients.

3.
Front Cardiovasc Med ; 8: 821988, 2021.
Article in English | MEDLINE | ID: mdl-35155622

ABSTRACT

BACKGROUND: This study describes the electrophysiologic characteristics of the para-hisian accessory pathway (AP), the outcome of different ablation approaches, and ablation safety at different sites. METHOD: A total of 120 patients diagnosed as para-hisian AP were included in this study. The electrophysiologic characteristics and outcomes at different ablation sites were analyzed. RESULTS: In total, 107 APs and 13 APs were diagnosed as right anteroseptal (RAS) and right midseptal (RMS), respectively. The significant ECG difference between RAS and RMS was lead III, which mainly manifested as positive and negative delta waves, respectively. Catheter trauma to AP was recorded in 21 of 120 (17.5%) patients. The recurrence rate of direct ablation at the "bumped" sites was higher than the conventional ablation method (37.5 vs. 14.1 %, p = 0.036). For RAS APs, there was no significant difference in the success rate between the inferior vena cava (IVC) and superior vena cava (SVC) approaches (76.6 vs. 73.3%, p = 0.63). The RAS was separated into three regions: (1) Site 1: superior part above the real "His" recorded site with far-field "His" potential; (2) Site 2 (true para-hisian): the site with near-field "His" potential; and (3) Site 3: inferior part below the biggest real "His" with far-field "His" potential. Mid-septal was defined as an area that is bounded anteriorly by His recording location and posteriorly by the roof of coronary sinus (CS) ostium. The incidence of atrioventricular (AV) conduction injury at different sites was as follows: 3 of 6 (50%) at Site 2, 4 of 13 (30.8%) at RMS, 7 of 34 (20.6%) at Site 3, and 3 of 46 (6.5%) at Site 1. Even if ablation was performed at the atrial side of the para-hisian region, the right bundle branch block (RBBB) was caused in 6 patients (5%). CONCLUSION: Ablation via IVC or SVC was comparative for para-hisian APs, but not for the noncoronary cusp (NCC) approach. The AV conduction injury risk ranks as follows: Site 2 > RMS > Site 3 > Site 1. RBBB could be caused while ablating at the atrial side, which could further demonstrate the His bundle longitudinal dissociation theory.

4.
J Interv Card Electrophysiol ; 56(3): 271-278, 2019 Dec.
Article in English | MEDLINE | ID: mdl-30617678

ABSTRACT

PURPOSE: We aimed to investigate the characteristics of focal atrial tachycardias (ATs) arising from the pulmonary veins (PVs), as well as the safety and long-term efficacy of cryoballoon (CB) versus radiofrequency (RF) ablation in this population. METHODS: Eighty-three patients with ATs arising from PVs from a consecutive series of 487 patients who underwent CB and RF ablation were retrospectively reviewed. Patients who had a prior history of atrial fibrillation (AF) were excluded. The AT origin was confirmed during the conventional electrophysiological study and activation mapping. The ablation approach was at the discretion of the operators. RESULTS: Thirty-five patients were managed with focal ablation, 25 were ablated with unilateral PV isolation (PVI), and the remaining 23 were performed with CB ablation. All procedures were successfully ablated. There was no significant difference in procedure time between CB group and RF focal group (43.7 ± 11.8 min vs. 45.8 ± 11.2 min, P = 0.121), whereas the fluoroscopy time in CB group was longer than in RF PVI group (10.1 ± 2.5 min vs. 8.4 ± 2.8 min, P < 0.001). There was 1 recurrence in CB group, 4 recurrences of AT in RF focal group, and 2 recurrence in RF PVI group (P = 0.643). Repeat ablation was performed in 6 of 7 patients. Seventy-eight patients were available for long-term follow-up. At a mean of 5.4 ± 4.6-year follow-up, 77 of 78 patients were free from AT without antiarrhythmic medication after 1.1 ± 0.3 procedures. No patient had procedural complications and developed AF during the follow-up period. CONCLUSIONS: CB ablation is an effective and safe tool to treat ATs originating from the PVs. The ATs originating from the PVs represent an isolated clinical process and are not likely to be the forerunner of a more diffuse process leading to the development of PV AF.


Subject(s)
Atrial Fibrillation/surgery , Catheter Ablation/methods , Cryosurgery/methods , Mitral Valve Stenosis/surgery , Pulmonary Veins/surgery , Rheumatic Heart Disease/surgery , Aged , Electrocardiography , Female , Humans , Male , Retrospective Studies
5.
J Cardiovasc Electrophysiol ; 30(4): 541-549, 2019 04.
Article in English | MEDLINE | ID: mdl-30661263

ABSTRACT

BACKGROUND: While the left sinus of Valsalva (LSV) is a frequent origin of ventricular arrhythmias (VAs). Uncommonly, VAs with right bundle branch block (RBBB) morphology may be successfully terminated from the LSV. OBJECTIVE: We aimed to investigate the electrocardiographic and electrophysiologic characteristics of VAs with RBBB which were successfully eliminated from the LSV. METHODS: We identified patients with VAs successfully ablated from the LSV from January 2014 to December 2017 and compared electrophysiologic characteristics and ablation sites of those VAs with RBBB versus a control group of patients with left bundle branch block morphology. RESULTS: We identified 18 patients with RBBB and predominant "R" waves in the precordial leads. In 12 (66.7%) patients, a small "s" wave in lead V2 and positive "R" in the remaining pericardial leads could be seen. Overall, a single "V" potential was seen in 72.2% of patients in the study group, while discrete potentials were recorded in 80% of the patients in the control group. The majority (88.9%) of the VAs could only be terminated at the nadir of the LSV in the study group. After mean follow-up of 33 ± 14 months, 93.8% and 92% were free of VAs after initial ablation in study and control group, respectively (P = 0.99). CONCLUSION: Some VAs with predominant monophasic "R" wave in precordial leads could be terminated from LSV, especially a small "s" wave in lead V2 was recorded. The nadir of LSV is highly successful for RBBB VAs and single electrogram was recorded at the target for most of the cases.


Subject(s)
Bundle-Branch Block/surgery , Catheter Ablation , Electrocardiography , Electrophysiologic Techniques, Cardiac , Heart Rate , Sinus of Valsalva/surgery , Tachycardia, Ventricular/surgery , Ventricular Premature Complexes/surgery , Action Potentials , Adult , Aged , Bundle-Branch Block/diagnosis , Bundle-Branch Block/physiopathology , Catheter Ablation/adverse effects , Female , Humans , Male , Middle Aged , Predictive Value of Tests , Retrospective Studies , Sinus of Valsalva/physiopathology , Tachycardia, Ventricular/diagnosis , Tachycardia, Ventricular/physiopathology , Treatment Outcome , Ventricular Premature Complexes/diagnosis , Ventricular Premature Complexes/physiopathology , Young Adult
6.
J Cardiovasc Electrophysiol ; 30(4): 557-564, 2019 04.
Article in English | MEDLINE | ID: mdl-30661266

ABSTRACT

BACKGROUND: Dextrocardia with situs inversus is a rare cardiac positional anomaly. Catheter ablation procedures performed in this set of patients have not been sufficiently reported. METHODS: A total of 10 patients with dextrocardia and situs inversus who received catheter ablation for supraventricular tachycardia (SVT) were included from a cohort of over 20 000 cases of catheter ablation for SVT in three centers from 2005 to 2016. All patients underwent electrophysiologic study and catheter ablation of SVT. Ablation targets were selected based on different tachycardia mechanisms with the primary endpoint of noninduction of tachycardia. RESULTS: The average age was 32.4 ± 5.6 years. Congenitally corrected transposition of great arteries (TGA) with situs inversus and D-looping of the ventricles and aorta (congenitally corrected TGA {I,D,D}) was found in four patients, while the other six patients exhibited mirror-image dextrocardia {I,L,L}. The mechanisms of SVT were atrioventricular nodal reentrant tachycardia in four patients, atrioventricular reentrant tachycardia in three, typical atrial flutter in one, intra-atrial reentrant tachycardia in one, and focal atrial tachycardia in one. Immediate procedural success was achieved in 9 out of 10 patients with no procedural complications. During a follow-up period of 6.3 ± 3.5 years on average, all patients remained free from recurrent tachycardia. CONCLUSIONS: For patients with dextrocardia and situs inversus, catheter ablation of SVT is safe and feasible. Differences in catheter maneuver and fluroscopy projection, along with difficulties in distorted anatomy are major obstacles for successful ablation.


Subject(s)
Atrial Flutter/surgery , Catheter Ablation , Dextrocardia/complications , Tachycardia, Atrioventricular Nodal Reentry/surgery , Tachycardia, Supraventricular/surgery , Action Potentials , Adult , Aged , Atrial Flutter/complications , Atrial Flutter/diagnosis , Atrial Flutter/physiopathology , Beijing , Catheter Ablation/adverse effects , Child , Dextrocardia/diagnostic imaging , Dextrocardia/physiopathology , Electrocardiography , Electrophysiologic Techniques, Cardiac , Female , Heart Rate , Humans , Male , Middle Aged , Tachycardia, Atrioventricular Nodal Reentry/complications , Tachycardia, Atrioventricular Nodal Reentry/diagnosis , Tachycardia, Atrioventricular Nodal Reentry/physiopathology , Tachycardia, Supraventricular/complications , Tachycardia, Supraventricular/diagnosis , Tachycardia, Supraventricular/physiopathology , Treatment Outcome , Young Adult
7.
J Cardiovasc Electrophysiol ; 30(1): 32-38, 2019 01.
Article in English | MEDLINE | ID: mdl-30288848

ABSTRACT

INTRODUCTION: The procedural findings and clinical outcome of second-generation cryoballoon (CB2) ablation in patients with variant pulmonary vein (PV) anatomy have not been fully investigated. METHODS: A total of 424 consecutive patients who underwent PV isolation with CB2 were included. Computed tomographic (CT) scan was performed in all patients before the procedure. The study population was divided into common PV, accessory PV, and nonvariant PV groups according to the CT scan. Procedural findings and clinical outcome between the three groups were compared. RESULTS: Variant PV anatomy was observed in 118 of 424 (27.8%) patients. PV isolation was successfully achieved in all patients in three groups with low rates of need for touch-up ablation (P = 0.974). Total procedure time was longer in the accessory PV group compared with nonvariant PV group (53.7 ± 12.9 vs 49.5 ± 8.8 minutes; P < 0.001). More number of applications per patient were required in accessory PV group compared with the nonvariant PV and common PV groups (7.5 ± 2.1 vs 6.5 ± 1.6, P < 0.001; 7.5 ± 2.1 vs 6.8 ± 1.4, P = 0.027, respectively). No significant difference in phrenic nerve (PN) injury was observed between the three groups (P = 0.693). During mean follow-up duration of 16.1 ± 3.3 months, there was no significant difference in rates of atrial fibrillation (AF) recurrences in the three groups (13 of 43 common PV group, 21 of 75 accessory PV group, and 80 of 306 nonvariant PV group, P = 0.178). CONCLUSION: Variant PV patterns are common in patients undergoing ablation for drug-resistant AF. CB2 ablation appears to be a reasonable strategy in the setting of the variant PV anatomy with a small increase in procedure time and the number of cryoapplications.


Subject(s)
Atrial Fibrillation/surgery , Cryosurgery , Pulmonary Veins/abnormalities , Pulmonary Veins/surgery , Action Potentials , Adult , Aged , Atrial Fibrillation/diagnosis , Atrial Fibrillation/physiopathology , Computed Tomography Angiography , Cryosurgery/adverse effects , Female , Heart Rate , Humans , Male , Middle Aged , Postoperative Complications/etiology , Pulmonary Veins/diagnostic imaging , Pulmonary Veins/physiopathology , Recurrence , Retrospective Studies , Risk Factors , Time Factors , Treatment Outcome
8.
J Cardiovasc Electrophysiol ; 29(7): 958-965, 2018 07.
Article in English | MEDLINE | ID: mdl-29858877

ABSTRACT

INTRODUCTION: To assess the predictors of hemoptysis using second-generation cryoballoon (CB). METHODS: Thirty patients with hemoptysis after second-generation CB ablation and 60 age-, gender-, and body mass index-matched controls were recruited. Anatomic parameters were obtained from preprocedural cardiac computed tomography (CT). Pulmonary vein isolation was performed with 28-mm balloon using single 3-minute freeze technique. RESULTS: Clinical and procedural characteristics were similar between the groups. A shorter distance between left superior PV (LSPV) and left main bronchus (LMB) was associated with hemoptysis (7.8 ± 4.3 mm vs. 12.5 ± 3.5 mm, P < 0.001), whereas no significant difference in the distance between right superior PV (RSPV) and right main bronchus (RMB) was found between groups (11.9 ± 3.5 mm vs. 12.9 ± 4.6 mm, P = 0.089). Additionally, the mean thickness of the connective tissue interposed between RSPV and RMB was significantly thicker than that between LSPV and LMB in both groups (both P < 0.001). A stepwise logistic multivariate analysis identified only the LMB-LSPV distance as an independent predictor of hemoptysis (odd ratio [OR] 2.676; 95% CI 1.121-4.843, P < 0.001). A cutoff value ≤ 9.5 mm predicted hemoptysis after CB ablation with 93.8% sensitivity and 75.0% specificity. CONCLUSION: Hemoptysis is a relatively rare event following second-generation CB ablation. The bronchi location obtained from CT aids in identifying high-risk population for the complication.


Subject(s)
Catheterization, Central Venous/adverse effects , Cryosurgery/adverse effects , Hemoptysis/diagnostic imaging , Pulmonary Veins/diagnostic imaging , Pulmonary Veins/surgery , Aged , Female , Follow-Up Studies , Hemoptysis/etiology , Humans , Male , Middle Aged , Predictive Value of Tests , Treatment Outcome
9.
Heart Rhythm ; 15(11): 1626-1633, 2018 11.
Article in English | MEDLINE | ID: mdl-29803021

ABSTRACT

BACKGROUND: Catheter ablation of ventricular arrhythmias (VAs) originating from the para-Hisian region could be challenging because of a potential damage to atrioventricular conduction system. OBJECTIVE: The purpose of this study was to evaluate the safety and efficacy of catheter ablation of VAs originating from the para-Hisian region via a systematic direct approach from aortic sinus cusps (ASCs). METHODS: Twenty-one consecutive patients with VAs with para-Hisian origin were included. Electrophysiological mapping of the entire right ventricle was initially performed, and then retrograde ASC mapping was performed when the earliest ventricular activation was recorded in the His bundle region. Ablation was preferentially performed within ASCs in all patients. RESULTS: Radiofrequency energy delivery resulted in the elimination of VAs in 17 of 21 patients (81%). In the remaining 4 patients, radiofrequency application was initiated at the target site of the right ventricular septum around the His bundle region and clinical VAs were finally successfully eliminated without junctional rhythm in 2 of 4 patients. During a mean follow-up of 34.8 ± 11.3 months, 1 of the 19 acute successful patients had VA recurrence. No procedure-related complications occurred during ablation or follow-up. CONCLUSION: Catheter ablation of VAs originating from the para-Hisian region via a direct approach from ASCs may be safe and effective in most unselected patients.


Subject(s)
Body Surface Potential Mapping/methods , Bundle of His/physiopathology , Catheter Ablation/methods , Sinus of Valsalva/surgery , Tachycardia, Ventricular/surgery , Adult , Angiography , Bundle of His/surgery , Female , Follow-Up Studies , Humans , Male , Retrospective Studies , Tachycardia, Ventricular/diagnosis , Tachycardia, Ventricular/physiopathology , Treatment Outcome
10.
Heart Rhythm ; 15(8): 1148-1157, 2018 08.
Article in English | MEDLINE | ID: mdl-29625278

ABSTRACT

BACKGROUND: Right atrial (RA) dual-loop reentrant tachycardia has been described in patients who have undergone open heart surgery. However, the prevalence, electrophysiological (EP) substrate, and ablation outcomes have been poorly characterized. OBJECTIVE: The purpose of this study was to investigate the prevalence, EP substrate, and ablation outcomes for RA dual-loop reentrant tachycardia after cardiac surgery. METHODS: We identified all patients with atrial tachycardia (AT) after cardiac surgery. We compared EP findings and outcomes of those with RA dual-loop reentrant tachycardia to a control group of patients with RA macroreentrant arrhythmias in the setting of linear RA free-wall (FW) scar. RESULTS: Of the 127 patients with 152 postsurgical ATs, 28 of the ATs (18.4%) had RA dual-loop reentry and 24 of 28 (85.7%) had tricuspid annular reentry combined with FW incisional reentry. An incision length >51.5 mm along the FW predicted the substrate for a second loop. In 22 of 23 patients (95.7%) with initial ablation in the cavotricuspid isthmus, a change in the interval between Halod to CSp could be recorded, and 15 of 23 patients (65.2%) had coronary sinus activation pattern change. Complete success was achieved in 25 of 28 patients (89.3%) in the dual-loop reentry group and in 64 of 69 patients (92.8%) in the control group. After mean follow-up of 33.9 ± 24.2 months, 24 of 28 patients (85.7%) and 60 of 69 patients (86.95%) were free of arrhythmias after the initial procedure in the 2 groups, respectively. CONCLUSION: The prevalence of RA dual-loop reentry is 18.4% of ATs with prior atriotomy scar. A long incision should alert physicians to the possibility of a second loop at the FW. Halo and coronary sinus activation patterns provide important clues to circuit transformation.


Subject(s)
Cardiac Surgical Procedures/adverse effects , Catheter Ablation/methods , Electrophysiologic Techniques, Cardiac/methods , Heart Conduction System/physiopathology , Postoperative Complications , Tachycardia, Atrioventricular Nodal Reentry/epidemiology , Adult , China/epidemiology , Female , Heart Conduction System/surgery , Humans , Male , Middle Aged , Prevalence , Tachycardia, Atrioventricular Nodal Reentry/etiology , Tachycardia, Atrioventricular Nodal Reentry/surgery , Treatment Outcome
11.
Pacing Clin Electrophysiol ; 41(6): 635-642, 2018 06.
Article in English | MEDLINE | ID: mdl-29603258

ABSTRACT

INTRODUCTION: The "Crosstalk" technique: if pulmonary vein isolation (PVI) of the superior one is not achieved due to a gap in the inferior part, it could be done during inferior vein cryoablation. This maneuver minimizes the total energy delivery time and number of lesions. We aimed to correlate the likelihood of crosstalk phenomenon with certain anatomic characteristics. METHODS: A total of 676 patients undergoing a first ablation procedure for paroxysmal or persistent atrial fibrillation (470 first-generation cryoballoon [CB] and 206 second-generation CB) between June 2014 and December 2016 were included. RESULTS: "Crosstalk" phenomenon occurred in 32 patients (18 first-generation CB, 14 second-generation CB). Compared to 54 control patients without crosstalk, the angle between left superior pulmonary vein (LSPV) and left atrial (LA) roof-plane, left pulmonary common ostia were significant parameters associated with crosstalk (odds ratio [OR] = 1.20, ±95% confidence interval [CI]: 1.11-1.31, P < 0.001; OR = 5.67, ±95% CI: 1.08-28.69, P = 0.04). As for angle between LSPV and LA roof-plane, the cut-off value was 28.68° with a sensitivity of 72.22%, a specificity of 81.25%, and an area under the receiver operating characteristic curve of 0.87 to predict the possibility of crosstalk technique application to get isolated in LSPV. Among the crosstalk group, there was no statistical difference between first-generation CB and second-generation CB in pulmonary anatomic characteristics. CONCLUSION: Crosstalk technique can be effective in patients with AF undergoing CB ablation using with both first and second-generation CBs. Anatomic characteristics predictive of crosstalk include a left common ostia and smaller angle between the LSPV and LA roof-plane.


Subject(s)
Atrial Fibrillation/surgery , Cryosurgery/instrumentation , Pulmonary Veins/surgery , Atrial Fibrillation/diagnostic imaging , Cardiac-Gated Imaging Techniques , Contrast Media , Electrocardiography , Equipment Design , Humans , Imaging, Three-Dimensional , Iohexol/analogs & derivatives , Middle Aged , Pulmonary Veins/diagnostic imaging , Retrospective Studies , Tomography, X-Ray Computed , Treatment Outcome
12.
Europace ; 20(4): 673-681, 2018 04 01.
Article in English | MEDLINE | ID: mdl-28160481

ABSTRACT

Aims: We sought to investigate the clinical, electrocardiographic, and electrophysiological characteristics of left upper septal fascicular ventricular tachycardia (LUS-VT). Methods and results: Eleven consecutive patients with LUS-VT were identified among 196 patients with left fascicular ventricular tachycardia (VT). Clinical VTs presented as paroxysmal in 8 patients and incessant in 3 patients. Six patients had previous left posterior fascicular VT ablation history. All VTs had narrow QRS complexes with QRS duration of 101.1 ± 9.2 ms. The frontal QRS axis was normal or right deviation. Precordial morphology was either right bundle branch block type or similar to that of sinus rhythm. A retrograde His with H-V interval of 21.9 ± 7.2 ms was recorded during VT. The earliest Purkinje potential (PP) to QRS interval during VT averaged 35.7 ± 4.5 ms. Clear diastolic potentials (DPs) with high frequency and low amplitude were found in only one patient. Ten patients were managed successfully by 11 ablation sessions, and 1 patient declined ablation. Successful targets at the left upper septum were sites with the earliest PP (9 cases) or with DP (1 case) during VT. After ablation, 2 cases (10%) developed new left anterior hemiblock or incomplete left bundle branch block. No VT recurred during a median follow-up period of 3.2 (range 1.0-12.7) years. Conclusion: LUS-VT presented as narrow QRS complex tachycardia. Some LUS-VTs occurred after ablation targeting left posterior fascicular VT. The VTs can be managed successfully by focal ablation at the left upper septum with a mild risk of fascicular injury.


Subject(s)
Action Potentials , Electrocardiography , Electrophysiologic Techniques, Cardiac , Heart Rate , Purkinje Fibers/physiopathology , Tachycardia, Ventricular/diagnosis , Adolescent , Adult , Catheter Ablation/adverse effects , Female , Humans , Male , Middle Aged , Predictive Value of Tests , Purkinje Fibers/surgery , Retrospective Studies , Tachycardia, Ventricular/physiopathology , Tachycardia, Ventricular/surgery , Time Factors , Treatment Outcome
13.
Pacing Clin Electrophysiol ; 41(1): 14-21, 2018 01.
Article in English | MEDLINE | ID: mdl-29087000

ABSTRACT

OBJECTIVE: The study sought to evaluate the procedural and biophysical factors related to acute pulmonary vein isolation (PVI) guided by real-time pulmonary vein (PV) potential recordings. METHODS: A total of 180 consecutive patients with drug-resistant atrial fibrillation (AF) undergoing CB2 (second-generation version of cryoballoon) ablation were enrolled. Real-time monitoring of PV potentials was obtained using an inner lumen spiral mapping catheter. RESULTS: Acute isolation was achieved in all PVs without touch-up ablation. Real-time assessment of PV disconnection was possible in 611 of 711 (85.9%) PVs. A total of 617 (86.8%) PVs were isolated during the initial freeze. Longer time cycle integration (TCI) (TTI * freeze cycle, TCI) (254.6 ± 112.8 seconds vs 74.1 ± 59.7 seconds, P < 0.001), time to isolation (TTI) (94.3 ± 34.0 seconds vs 46.3 ± 26.2 seconds, P < 0.001), higher nadir temperature (-45.5 ± 5.3°C vs -50.4 ± 5.5°C, P < 0.001), longer time to -40°C (77.3 ± 22.7 seconds vs 55.7 ± 23.2 seconds, P < 0.001), faster interval rewarming time at 0°C (9.4 ± 4.3 seconds vs 12.4 ± 4.9 seconds, P = 0.008), and total balloon rewarming time (38.1 ± 11.6 seconds vs 47.7 ± 14.0 seconds, P = 0.003) were observed in PVs with acute reconduction. TTI ≤ 65 seconds predicted absence of acute reconnection with 84.2% sensitivity and 75.7% specificity, whereas TCI ≤ 119 seconds presented 94.7% sensitivity and 80.2% specificity. At a mean follow-up of 4.7 ± 1.4 months, 82.2% of patients were free of AF. None of those with PV reconnections suffered from AF recurrences. CONCLUSIONS: The ablation using CB2 is effective in achieving acute PVI. Real-time assessment of PVI could be achieved during CB application in 86% of PVs. The incidence of spontaneous PV reconnection is very low, observed in just 3% of isolated PVs. TTI ≤ 65 seconds and TCI ≤ 119 seconds predicted absence of acute PV reconnection. Although they may identify effective cryoapplications in the acute phase, their performance still needs to be verified in the long term.


Subject(s)
Atrial Fibrillation/surgery , Cryosurgery/methods , Pulmonary Veins/surgery , Atrial Fibrillation/diagnostic imaging , Echocardiography , Electrocardiography , Female , Humans , Male , Middle Aged , Retrospective Studies , Treatment Outcome
14.
Europace ; 20(10): 1666-1674, 2018 10 01.
Article in English | MEDLINE | ID: mdl-29244066

ABSTRACT

Aims: We aimed to examine the electrocardiographic and electrophysiologic characteristics of anterograde-conducting decremental accessory pathways (DAP) and to identify surrogate criteria to distinguish short atrioventricular (SAV) DAP from atriofascicular (AF) AP and long atrioventricular (LAV) DAP. Methods and results: We identified all patients with DAPs and analysed electrocardiographic and electrophysiologic characteristics. Distal insertion sites were examined using existing criteria, including V-H interval, ventricular activation at the right ventricular apex, and around tricuspid annulus during antidromic atrioventricular re-entrant tachycardia (A-AVRT) or complete pre-excitation and evaluated the AV node-like properties according to the response to adenosine and radiofrequency ablation. Out of 45 patients with DAPs, 28 (62.2%) had SAV-DAP (13 with definite AF-AP, 2 with definite LAV-DAP, 2 indeterminate). In all, 50% of SAV-DAPs and 53.3% of AF-AP/LAV-DAPs had 'rS' pattern in lead III. Longer QRS duration (159.9 ± 17.4 ms vs. 139.2 ± 14.3 ms, P < 0.0001) during full pre-excitation or A-AVRT differentiated SAV-DAP from AF-AP. The QRS-V(His) interval was longer for those with SAV-DAP compared vs. AF-AP/LAV-DAP (45.3 ± 2.4 ms vs. 22.9 ± 2.5 ms, P < 0.0001) and a cut-off value of 33.0 ms differentiated the two (sensitivity 81.3%, specificity 87.5%). Conclusion: The majority of the SAV-DAPs are located at the TA free wall. An 'rS' pattern in lead III is frequently seen in SAV-DAP as well as AF-AP/LAV-DAPs. Measuring the QRS-V(His) interval would be helpful to distinguish SAV-DAP from AF-AP/LAV-DAP.


Subject(s)
Accessory Atrioventricular Bundle/physiopathology , Action Potentials/physiology , Accessory Atrioventricular Bundle/classification , Adolescent , Adult , Aged , Child , Ebstein Anomaly/physiopathology , Electrocardiography , Electrophysiologic Techniques, Cardiac , Female , Humans , Male , Middle Aged , Retrospective Studies , Young Adult
15.
Heart Rhythm ; 14(9): 1344-1350, 2017 09.
Article in English | MEDLINE | ID: mdl-28476679

ABSTRACT

BACKGROUND: Focal atrial tachycardias (ATs) from the parahisian region can be successfully ablated from the right atrial septum (RAS), noncoronary cusp (NCC), and right middle septum (RMS). The optimal mapping and ablation strategy for ATs from these sites remains unclear. OBJECTIVE: The purpose of this study was to investigate the electrophysiologic characteristics and optimal ablation sites of parahisian ATs from the RAS, RMS, and NCC. METHODS: A total of 362 patients with ATs undergoing radiofrequency catheter ablation of ATs were included. A detailed examination including ECG analysis and electrophysiologic study was performed. RESULTS: Overall, 91 patients had a parahisian site of AT origin, and ablation was successful in 86 (94.5%). ATs were successfully eliminated from the RAS in 23, RMS in 19, and NCC in 44. The earliest "A" potential was recorded at the distal His catheter in 69.4% of NCC ATs vs the proximal His catheter in 83.3% of RAS ATs and 86.7% of RMS ATs. Mean timing of the "A" potential of RMS ATs recorded at the His-bundle catheter was -18.25 ± 7.20 ms, which was later than ATs from the RAS (-24.59 ± 8.73 ms) or NCC (-27.08 ± 5.63 ms). For ATs originating from the RAS and RMS, an A/V ratio <1.22 predicted safe and successful ablation (sensitivity 88.4%, specificity 91.7%). CONCLUSION: For parahisian ATs, activation sequence and timing of the "A" on the His catheter can provide clues for the origin of ATs. When ablating at the RAS and RMS, an A/V ratio >1.22 identified safe and effective ablation sites.


Subject(s)
Atrial Appendage/surgery , Bundle of His/physiopathology , Catheter Ablation/methods , Electrocardiography/methods , Electrophysiologic Techniques, Cardiac , Heart Atria/physiopathology , Tachycardia, Supraventricular/diagnosis , Atrial Appendage/diagnostic imaging , Bundle of His/surgery , Female , Fluoroscopy/methods , Follow-Up Studies , Heart Atria/diagnostic imaging , Humans , Male , Retrospective Studies , Surgery, Computer-Assisted/methods , Tachycardia, Supraventricular/physiopathology , Tachycardia, Supraventricular/surgery , Treatment Outcome
16.
Europace ; 19(12): 2015-2022, 2017 Dec 01.
Article in English | MEDLINE | ID: mdl-27965318

ABSTRACT

AIMS: We sought to investigate focal atrial tachycardias (ATs) in patients with congenitally corrected transposition of the great arteries (ccTGA). METHODS AND RESULTS: We identified three cases of focal ATs with ccTGA from 2007 to 2015. The clinical findings, electrocardiography, electrophysiological features, and ablation were reported. All three cases had {S,L,L}-type ccTGA. The AT P waves shared the following features: narrow in width, positive in leads I and aVL, and negative/positive in lead V1. All ATs had focal activation pattern with early activation at the anteroseptal area, and further mapping demonstrated earliest atrial activation (EAA) inside the pulmonary sinus cusps (PSCs), especially the right PSC. In Cases 1 and 2, double potentials were recorded at the EAA sites. Conduction delay between the two potentials during atrial extrastimulus was observed. After successful ablation, the second potential during sinus rhythm was further delayed in Case 1 and was eliminated in Case 2. However, only one potential was recorded in Case 3. All three cases were successfully managed by ablating the sites with EAA, which preceded the P-wave onset by 60, 80, and 42 ms, respectively. During ablation, no junctional rhythm was observed. Incomplete left bundle branch block was induced during mapping in Case 1, but no other complications occurred. All patients were free from tachycardia during follow-up periods of 36, 7, and 5 months, respectively. CONCLUSION: Anteroseptal AT in patients with ccTGA could be eliminated by ablation inside the PSC.


Subject(s)
Catheter Ablation , Electrocardiography , Electrophysiologic Techniques, Cardiac , Pulmonary Artery/surgery , Tachycardia, Atrioventricular Nodal Reentry/diagnostic imaging , Tachycardia, Atrioventricular Nodal Reentry/surgery , Tachycardia, Supraventricular/diagnosis , Tachycardia, Supraventricular/surgery , Transposition of Great Vessels/complications , Action Potentials , Adolescent , Adult , Catheter Ablation/adverse effects , Congenitally Corrected Transposition of the Great Arteries , Female , Heart Rate , Humans , Male , Predictive Value of Tests , Pulmonary Artery/abnormalities , Pulmonary Artery/diagnostic imaging , Pulmonary Artery/physiopathology , Risk Factors , Tachycardia, Atrioventricular Nodal Reentry/complications , Tachycardia, Atrioventricular Nodal Reentry/physiopathology , Tachycardia, Supraventricular/complications , Tachycardia, Supraventricular/physiopathology , Tomography, X-Ray Computed , Transposition of Great Vessels/diagnosis , Transposition of Great Vessels/physiopathology , Treatment Outcome , Young Adult
17.
Int J Cardiol ; 205: 72-80, 2016 Feb 15.
Article in English | MEDLINE | ID: mdl-26720044

ABSTRACT

BACKGROUND: The arrhythmogenicity of right atrial (RA) incisional scar after cardiac surgery could result in atrial tachycardia (AT). Radiofrequency catheter ablation is effective in the treatment of such tachycardia. However, data regarding long-term outcomes are limited. METHODS AND RESULTS: A total of 105 patients with prior RA incision who underwent radiofrequency catheter ablation of AT were included. In the first procedure, electroanatomic mapping (EAM) revealed a total of 139 ATs in 105 patients, including 88 cavotricuspid isthmus dependent atrial flutters (IDAFs), 5 mitral annulus reentrant tachycardias (MARTs), 44 intra-atrial reentrant tachycardias (IARTs) and 2 focal ATs (FATs). AT was successfully eliminated in 101 (96.1%) patients. During a mean follow-up period of 90 ± 36 months, recurrent AT was observed in 23 patients and 21 underwent a second ablation. A total of 23 ATs were identified in redo procedures including 4 IDAFs, 2 MARTs, 12 IARTs and 5 FATs. The time to recurrence was significantly different among various AT types. Acute success was achieved in 20 of 23 redo procedures. Taking a total of 21 patients presenting atrial fibrillation during follow-up into account, 85 patients (81.9%) were in sinus rhythm. No complications except for a case of RA compartmentation occurred. CONCLUSION: RA incisional scar played an essential role in promoting both IDAF and IART, while non-incisional scar contributed to a substantial rate of late recurrent AT in forms of both macroreentry and small reentry. Catheter ablation using EAM system resulted in a high success rate during long-term follow-up.


Subject(s)
Atrial Fibrillation/epidemiology , Atrial Fibrillation/surgery , Cardiac Surgical Procedures/adverse effects , Catheter Ablation/adverse effects , Cicatrix/diagnosis , Cicatrix/epidemiology , Adult , Atrial Fibrillation/etiology , Cardiac Surgical Procedures/trends , Catheter Ablation/trends , Cicatrix/etiology , Female , Follow-Up Studies , Humans , Male , Middle Aged , Time Factors , Treatment Outcome
18.
Pacing Clin Electrophysiol ; 39(2): 173-81, 2016 Feb.
Article in English | MEDLINE | ID: mdl-26549840

ABSTRACT

BACKGROUND: Multiple intercostal recordings were supposed to get a more comprehensive view of the depolarization vector of the outflow tract ventricular arrhythmia (OT-VA), which may help to identify the OT-VA more accurately. This study was undertaken to develop a more accurate electrocardiogram (ECG) criterion for differentiating between left and right OT-VA origins. METHODS: We studied OT-VA with a left bundle branch block pattern and inferior axis QRS morphology in 47 patients with successful catheter ablation in the right ventricular OT (RVOT; n = 37) or aortic coronary cusp (ACC; n = 10). Superior and inferior precordial leads were taken together with the routine 12-lead ECG. The ECG during the OT-VA and during sinus beats were analyzed. Transition ratio, transition zone (TZ) index, R/S amplitude ratio, and R-wave duration ratio were measured in the regular, superior, and inferior precordial leads. RESULTS: The combined TZ index, TZ index inferior was significantly smaller, while the V2 inferior transition ratio was significantly larger for ACC origins than RVOT origins (P < 0.05). The area under the curve for the combined TZ index by a receiver operating characteristic analysis was 0.974, which was significantly larger than other parameters. A cutoff value ≤0.25 predicted an ACC origin with 94% sensitivity and 100% specificity. This advantage of the parameter over others also held true for a subanalysis of OT-VAs with a lead V3 precordial transition or TZ index = 0. CONCLUSIONS: The combined TZ index outperformed other ECG criteria to differentiate left from right OT-VA origins.


Subject(s)
Arrhythmias, Cardiac/diagnosis , Arrhythmias, Cardiac/physiopathology , Electrocardiography/methods , Heart Ventricles/physiopathology , Arrhythmias, Cardiac/surgery , Bundle-Branch Block/diagnosis , Bundle-Branch Block/physiopathology , Bundle-Branch Block/surgery , Catheter Ablation , Diagnosis, Differential , Electrophysiologic Techniques, Cardiac , Female , Humans , Male , Middle Aged , Prospective Studies , Treatment Outcome
19.
Pacing Clin Electrophysiol ; 38(9): 1073-81, 2015 Sep.
Article in English | MEDLINE | ID: mdl-26096255

ABSTRACT

BACKGROUND: Cryoballoon ablation is an alternative for the treatment of atrial fibrillation (AF). We assess the relationship among pulmonary vein (PV) electrophysiology, balloon temperature, and persistent PV isolation (PVI), and report procedural properties, safety, and efficacy of this technique in a Chinese center for the first time. METHODS: A total of 70 patients with paroxysmal (n = 57) and persistent (n = 13) AF were consecutively enrolled. PVI was performed with cryoballoon catheter. Real-time recording of dissociation of PV potentials was attempted using a circumferential mapping catheter. RESULTS: Successful PVI was achieved in 274 of 282 (97.2%) PVs. Procedural duration was 115.2 ± 24.8 minutes and fluoroscopy time was 29.6 ± 8.9 minutes. Real-time PV potential recording was achieved in 232 (84.3%) PVs. Regarding time to isolation, a cut-off value of less than 60 seconds was predictive of persistent PVI with a sensitivity of 0.76 and specificity of 0.82 (area under curve = 0.835; P < 0.0001). The nadir balloon temperature was significantly lower in PVs without early reconduction (-46.3 ± 0.5°C vs -40.2 ± 1.3°C, P < 0.0001). However, there was an insignificant trend that the balloon temperature at isolation was higher in PVs without reconduction (-33.9 ± 0.7°C vs -36.4 ± 2.0°C, P = 0.14). The overall complication rate was 5.7%. After a median follow-up of 6.5 (range 3.2-14.9) months, 76% of patients were free of AF recurrence with a blanking period of 3 months. CONCLUSIONS: Real-time PV potentials can be recorded in most PVs. The time to isolation is predictive of the persistency of PVI. The nadir balloon temperature, not the balloon temperature at isolation, is significantly lower in PVs without reconduction.


Subject(s)
Atrial Fibrillation/diagnosis , Atrial Fibrillation/surgery , Cardiac Catheterization/methods , Cryosurgery/methods , Heart Conduction System/surgery , Pulmonary Veins/surgery , Cardiac Catheterization/instrumentation , China , Cryosurgery/instrumentation , Female , Heart Conduction System/diagnostic imaging , Humans , Male , Middle Aged , Pulmonary Veins/diagnostic imaging , Treatment Outcome , Ultrasonography
20.
J Cardiovasc Electrophysiol ; 26(8): 845-852, 2015 Aug.
Article in English | MEDLINE | ID: mdl-25917416

ABSTRACT

BACKGROUND: The accessory pathway (AP) connecting the right atrial appendage (RAA) and the right ventricle (RV) is rare. OBJECTIVE: We sought to investigate the feature of the AP connecting the RAA and the RV and the efficacy of radiofrequency catheter ablation via the endocardial access. METHODS: We retrospectively analyzed 14 consecutive patients with 14 APs connecting the RAA and the RV managed by 15 procedures between January 2003 and December 2014. RESULTS: Ten patients presented as preexcitation during sinus rhythm. All APs had retrograde conduction. None had either antegrade or retrograde decremental conduction property. Ablation targeting the sites at the tricuspid annulus failed in all patients. They were successfully managed by ablating the atrial insertion sites with a median of 10.5 (range 5-28) radiofrequency applications. Electrograms at the successful target showed high amplitude atrial electrogram and low amplitude or no ventricular electrogram. The atrial insertion sites were at the floor of the RAA in 10 patients and inside the lower lobe of the RAA in the remaining 4 patients. The shortest distance between the successful target and the tricuspid annulus in the right anterior oblique projection was 19.7 ± 4.0 mm. There were no complications or recurrences during a median follow-up period of 4.3 (range 0.2-11.8) years. CONCLUSION: The APs connecting the RAA and the RV had typical conduction properties. The atrial insertion site favored the floor and the lower lobe of the RAA. Ablation targeting the atrial insertion sites was effective and safe, albeit multiple radiofrequency applications were needed.


Subject(s)
Accessory Atrioventricular Bundle/surgery , Arrhythmias, Cardiac/surgery , Atrial Appendage/surgery , Catheter Ablation , Electrophysiologic Techniques, Cardiac , Heart Ventricles/surgery , Accessory Atrioventricular Bundle/physiopathology , Action Potentials , Adolescent , Adult , Arrhythmias, Cardiac/diagnosis , Arrhythmias, Cardiac/physiopathology , Atrial Appendage/physiopathology , Catheter Ablation/adverse effects , Electrocardiography , Female , Heart Rate , Heart Ventricles/physiopathology , Humans , Male , Middle Aged , Predictive Value of Tests , Retrospective Studies , Time Factors , Treatment Outcome , Young Adult
SELECTION OF CITATIONS
SEARCH DETAIL
...