Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 4 de 4
Filter
Add more filters










Database
Language
Publication year range
1.
Curr Med Sci ; 41(2): 390-397, 2021 Apr.
Article in English | MEDLINE | ID: mdl-33877558

ABSTRACT

The features and treatment of 98 Chinese patients with immunoglobulin G4 (IgG4)-related disease (IgG4-RD) referred to a single tertiary referring centre were reviewed. Patients diagnosed with IgG4-RD according to the comprehensive diagnostic criteria (CDC) were included in the retrospective study from May 2012 to March 2019. We collected data on clinical, laboratory, imaging, histological features and treatment. Totally, 98 patients with IgG4-RD were enrolled. The common clinical manifestations included abdominal pain, salivary gland swelling and lymphadenopathy. 51% of the patients had multiple organs involvement. Lymph nodes, pancreas and salivary glands were most commonly involved. Four rare sites including ulna, cerebellum, scalp, and mammary gland were found. The serum IgG4 level was increased by 85.7%. The serum IgG4 level was positively correlated with the number of involved organs, IgG and IgG4/IgG. Low C3 and C4 levels were observed in 37.5% and 12.2% patients respectively, and all patients with kidney involvement had hypocomplementemia. A total of 54 patients underwent tissue biopsies, and 55.6%, 31.5% and 11.1% cases were diagnosed as definite, probable and possible IgG4-RD, respectively. Eighty-eight patients received glucocorticoids (GCs) therapy. Five patients underwent radical surgery to remove the lesion. 73% of them presented a complete or partial remission. IgG4-RD is a systemic fibroinflammatory disease with involvement of multiple organs throughout the body including some rare sites. Most IgG4-RD patients had increased serum IgG4 levels and patients with kidney involvement showed hypocomplementemia. GCs therapy is effective. More research is needed to provide a more reliable basis for the diagnosis and treatment of patients.


Subject(s)
Immunoglobulin G4-Related Disease/diagnosis , Immunoglobulin G4-Related Disease/therapy , Adolescent , Adult , Aged , Aged, 80 and over , Asian People , China , Complement C3/metabolism , Female , Humans , Immunoglobulin G/blood , Immunoglobulin G4-Related Disease/blood , Immunoglobulin G4-Related Disease/diagnostic imaging , Magnetic Resonance Imaging , Male , Middle Aged , Organ Specificity , Retrospective Studies , Treatment Outcome , Young Adult
2.
Front Med (Lausanne) ; 7: 605088, 2020.
Article in English | MEDLINE | ID: mdl-33330571

ABSTRACT

Objectives: To analyze follow-up CTs of patients recovering from COVID-19 in Wuhan, focusing on fibrotic change and its relevant risk factors. Methods: From January 13 to February 27, 2020, 166 hospitalized patients meeting our criteria were included. The scores of fibrotic patterns on follow-up CT were evaluated. Patients were designated as group 1 (with CT evidence of fibrotic pattern) and group 2 (without CT evidence of fibrotic pattern). Multivariate logistic regression was performed to explore risk factors for fibrotic change in patients with COVID-19. Results: The follow-up CTs were obtained on 56 days (median, IQR 51-63 days) after symptom onset. Of the 166 patients (mean age, 57 ± 15 years; 69/166 male), 46% (76/166) had CT evidence of fibrotic change and 77% (127/166) were severe or critical cases. Among patients with fibrotic change on CT, 84% (64/76) got a minimal or mild score of fibrosis. The high total score on peak CT, peak eosinophils, erythrocyte sedimentation rate (ESR) and advancing age were related to lung fibrotic change in patients with COVID-19. Conclusion: Forty six percentages of patients (mainly severe or critical cases) with COVID-19 showed fibrotic change on follow-up CT at early recovery phase, while the extent of fibrosis was not large. The advancing age, high total score on peak CT, peak eosinophils and ESR were associated with fibrotic change depicted by CT in patients recovering from COVID-19. An extended follow up by CT imaging and pulmonary function testing is necessary to fully assess the sequela of COVID-19.

3.
Curr Med Sci ; 40(1): 178-183, 2020 Feb.
Article in English | MEDLINE | ID: mdl-32166681

ABSTRACT

The effect of low voltage and low concentration contrast agent on image quality of coronary CT angiography, radiation dose and iodine intake was evaluated. A total of 121 patients with body mass index (BMI) <26 kg/m2 and heart rate (HR) <70 beats/min were randomly divided into four groups: group A (n=31, 80 kVp, 270 mgI/mL); group B (n=33, 100 kVp, 270 mgI/mL); group C (n=30, 100 kVp, 320 mgI/mL); group D (n=27, 100 kVp, 400 mgI/mL). The automatic current modulation system and the iterative algorithm for reconstruction were adopted in each group. The CT values and SD values of the aortic root (AR), subcutaneous fat, left coronary artery opening (LCA), and right coronary artery opening (RCA) were measured in all groups, the signal-to-noise ratio (SNR) and contrast noise ratio (CNR) were calculated, and effective radiation dose and iodine intake were recorded. The subjective assessment for image quality was performed by two physicians using a 4-point scale. The results were compared using the one-way ANOVA and rank sum tests. The image quality of the four groups met the clinical diagnostic requirements. The CT values of AR in groups A, B, C, and D were 537.6±71.4, 447.2±81.9, 445.2±64.9 and 518.5±94.9 Hu, respectively, with no significant difference between group A and group D, or between group B and group C, while CT values in groups B and C were significantly lower than those in groups A and D (P<0.05). In groups A, B, C, and D, the LCA SNR values were 22.7±9.1, 23.3±9.1, 23.3±7.7 and 26.6±8.9, and the RCA CNR values were 26.9±9.8, 28.5±11.4, 27.7±8.8 and 32.1±10.6, respectively. The AR visual scores in groups A, B, C and D were 3.8±0.2, 3.9±0.3, 3.9±0.3 and 4.0±0.3, respectively. There were no significant differences in SNR, CNR and visual score among the four groups (P>0.05). The radiation doses in groups A, B, C and D were 2.6±1.4, 3.6±1.8, 4.9±3.5 and 4.9±2.8 mSv, respectively. The radiation dose in group A was significantly less than that in the rest three groups (P<0.05). The iodine intakes in groups A, B, C and D were 14.9±1.5, 15.0±1.5, 17.7±2.0 and 18.1±2.5 g, respectively. There was no significant difference in the intake of iodine between groups C and D, or between groups A and B, while iodine intake in groups A and B were significantly reduced as compared with that in groups C and D (P<0.05). It was concluded that for patients with low BMI and controlled HR, compared to 100 kVp tube voltage combined with multiple concentration contrast agents, 80 kVp combined with 270 mgI/mL contrast agent is enough to ensure the quality of the images, and can reduce the radiation dose significantly, while reducing the amount of iodine intake notably, thus reducing the incidence of adverse reaction.


Subject(s)
Computed Tomography Angiography/methods , Coronary Angiography/methods , Triiodobenzoic Acids/administration & dosage , Adult , Aged , Body Mass Index , Female , Heart Rate , Humans , Male , Middle Aged , Prospective Studies , Radiation Dosage , Radiographic Image Enhancement , Random Allocation , Signal-To-Noise Ratio
4.
Curr Med Sci ; 38(5): 920-924, 2018 Oct.
Article in English | MEDLINE | ID: mdl-30341530

ABSTRACT

In order to prospectively assess various parameters of diffusion weighted imaging (DWI) in differential diagnosis of benign and malignant solitary pulmonary nodules (SPNs), 58 patients (40 men and 18 women, and mean age of 48.1±10.4 years old) with SPNs undergoing conventional MR, DWI using b=500 s/mm2 on a 1.5T MR scanner, were studied. Various DWI parameters [apparent diffusion coefficient (ADC), lesion-tospinal cord signal intensity ratio (LSR), signal intensity (SI) score] were calculated and compared between malignant and benign SPNs groups. A receiver operating characteristic (ROC) curve analysis was employed to compare the diagnostic capabilities of all the parameters for discrimination between benign and malignant SPNs. The results showed that there were 42 malignant and 16 benign SPNs. The ADC was significantly lower in malignant SPNs (1.40±0.44)×10-3 mm2/s than in benign SPNs (1.81±0.58)×10-3 mm2/s. The LSR and SI scores were significantly increased in malignant SPNs (0.90±0.37 and 2.8±1.2) as compared with those in benign SPNs (0.68±0.39 and 2.2±1.2). The area under the ROC curves (AUC) of all parameters was not significantly different between malignant SPNs and benign SPNs. It was suggested that as three reported parameters for DWI, ADC, LSR and SI scores are all feasible for discrimination of malignant and benign SPNs. The three parameters have equal diagnostic performance.


Subject(s)
Diffusion Magnetic Resonance Imaging , Lung Neoplasms/diagnosis , Neoplasms/diagnosis , Solitary Pulmonary Nodule/diagnosis , Aged , Diagnosis, Differential , Female , Humans , Lung Neoplasms/diagnostic imaging , Lung Neoplasms/physiopathology , Male , Middle Aged , Neoplasms/diagnostic imaging , Neoplasms/physiopathology , ROC Curve , Solitary Pulmonary Nodule/diagnostic imaging , Solitary Pulmonary Nodule/physiopathology
SELECTION OF CITATIONS
SEARCH DETAIL
...