Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 9 de 9
Filter
2.
Heart Rhythm ; 20(2): 217-223, 2023 02.
Article in English | MEDLINE | ID: mdl-36347456

ABSTRACT

BACKGROUND: Left bundle branch pacing (LBBP) is an alternative strategy for His-bundle pacing (HBP); however, little is known about tricuspid regurgitation (TR) deterioration after LBBP implantation. OBJECTIVES: The purpose of this study was to characterize the incidence of post-LBBP TR deterioration and identify predicting factors, especially lead position parameters. METHODS: Patients who received LBBP were continuously enrolled from January 2018 to August 2020. The progression of TR and the anatomic position of LBBP were characterized by echocardiography. RESULTS: A total of 89 patients were enrolled and assigned to 2 subgroups based on the degree of TR before LBBP implantation: 58 (65.2%) with relatively normal tricuspid valve (TV) function (grade 0/1 subgroup: with none/trivial or mild TR) and 31 (34.8%) with more severe TR (grade 2/3 subgroup: with moderate or severe TR). At 19.0 ± 6.5 months of follow-up, 29 patients (32.6%) had TR deterioration, and 23 of them were in the grade 0/1 subgroup. In the grade 0/1 subgroup, patients with TR deterioration had a shorter distance between the lead-implanted site and TV (Lead-TA-dist) than those without TR (19.0 ± 7.6 vs 23.9 ± 5.4; P = .006). The receiver operating characteristic (ROC) curve (area under the curve 0.721; 95% confidence interval [CI] 0.575-0.867; P = .005) indicated the favorable efficacy of Lead-TA-dist for predicting TR deterioration after LBBP. Lead-TA-dist ≤16.1 mm was independently associated with TR deterioration after LBBP (hazard ratio 0.20; 95% CI 0.06-0.76; P = .017). CONCLUSION: TR was a common complication of LBBP implantation. In patients with none/trivial or mild TR, Lead-TA-dist ≤16.1 mm was an independent predictor of TR deterioration after LBBP implantation.


Subject(s)
Pacemaker, Artificial , Tricuspid Valve Insufficiency , Humans , Tricuspid Valve Insufficiency/diagnosis , Tricuspid Valve Insufficiency/etiology , Pacemaker, Artificial/adverse effects , Cardiac Pacing, Artificial/adverse effects , Tricuspid Valve/diagnostic imaging , Tricuspid Valve/surgery , Time Factors , Bundle of His , Treatment Outcome , Electrocardiography
3.
Front Physiol ; 13: 996640, 2022.
Article in English | MEDLINE | ID: mdl-36187788

ABSTRACT

Background: Left bundle branch pacing (LBBP) is an alternative strategy for His bundle pacing (HBP). This study aimed to analyze the long-term performance of LBBP and the potential factors affecting long-term cardiac function. Methods: Patients with LBBP were continuously enrolled from January 2018 to August 2020. Pacing parameters, electrocardiogram (ECG), and echocardiography were collected. The anatomic position of LBBP leads was described by echocardiographic and fluoroscopic parameters. Results: A total of 91 patients with a median follow-up of 18 months were enrolled. Most patients maintained stable pacing parameters during follow-up. The intra-septal position of the 3830 lead also remained stable as the distance from the lead tip to the left surface of the ventricular septum was 0.4 (0, 1.4) mm. The overall level of left ventricular ejection fraction (LVEF) slightly increased. 59 patients had improved LVEF (∆LVEF > 0), while 28 patients had unchanged or reduced LVEF (∆LVEF ≤ 0). The declines of baseline LVEF, ∆ Paced QRSd, and corrected longitudinal distance (longit-dist) of lead-implanted site correlated with LVEF improvement, and these three factors had negative linear correlations with ∆LVEF. Patients with tricuspid valve regurgitation (TVR) deterioration had longer follow-up duration (20.5 vs. 15.0 months, p = 0.01) and shorter Lead-TVA-dist (18.6 vs. 21.6 mm, p = 0.04) than those without TVR deterioration. Conclusion: Patients with LBBP generally remained stable in pacing performance, anatomic lead positions, and cardiac function in long-term follow-up. Baseline LVEF, ∆ Paced QRSd, and corrected longit-dist might be associated with potential LVEF decrease, which required further confirmation.

4.
Front Physiol ; 13: 912126, 2022.
Article in English | MEDLINE | ID: mdl-35991167

ABSTRACT

Background: Left bundle branch area pacing (LBBAP) has become a safe and effective option for heart failure (HF) patients indicated for cardiac resynchronization therapy (CRT) and/or ventricular pacing, yet the response rate was only 70%. Repolarization parameters were demonstrated to be associated with cardiac mechanics and systolic function. This study aimed to investigate the effects of LBBAP on repolarization parameters and the potential association between those parameters and echocardiographic response. Methods and results: A total of 59 HF patients undergoing successful LBBAP were consecutively included. QTc, Tpeak-Tend (TpTe), and TpTe/QTc were measured before and after the implantation. The results turned out that the dispersion of ventricular repolarization (DVR) improved after LBBAP among the total population. Although trends of repolarization parameters varied according to different QRS configurations at baseline, the post-implant parameters showed no significant difference between groups. The association between repolarization parameters and LBBAP response was then evaluated among patients with wide QRS. Multivariate analysis demonstrated that post-implant TpTe was the independent predictor of LBBAP response (p < 0.05). Receiver operating characteristic analysis indicated an area under the curve of 0.77 (95% CI, 0.60-0.93) with a cutoff value of 81.2 ms (p < 0.01). Patients with post-implant TpTe<81.2 ms had a significantly higher rate of echocardiographic response (93.3 vs. 44.4%, p < 0.01). Further subgroup analysis indicated that the predictive value of post-implant TpTe for LBBAP response was more significant in non-left bundle branch block (LBBB) patients than in LBBB patients. Conclusion: LBBAP improved DVR significantly in HF patients. Post-implant TpTe was associated with the echocardiographic response after LBBAP among patients with wide QRS, especially for non-LBBB patients.

5.
Clin Res Cardiol ; 111(11): 1219-1230, 2022 Nov.
Article in English | MEDLINE | ID: mdl-34761309

ABSTRACT

BACKGROUND: Left bundle branch pacing (LBBP) is a novel near-physiological pacing method that still lacks quantitative criteria to guide the selection of lead-implanted sites to enhance the success likelihood of lead deployments. This study aimed to quantitatively analyze the relationships of LBBP success likelihood to the distribution of lead-implanted sites and the lead-localization-pacing electrocardiographic (ECG) features. METHODS: All the lead-implanted sites in patients with finally successful LBBP were enrolled for analysis, including successful and failed sites. A novel coordinate system was invented to describe the sites' distribution as longitudinal distance (longit-dist) and lateral distance (lat-dist). Corrected distance parameters were generated to eliminate the cardiac dimension variations. The lead-localization-pacing ECG parameters were also collected, such as paced QRS duration (locat-QRSd), left ventricular activation time (locat-LVAT), LVAT/QRSd ratio (locat-LVAT/QRSd), and QRS directions. RESULTS: A total of 94 patients with 105 successful sites and 93 failed sites were enrolled. Longit-dist and corrected longit-dist of successful sites were significantly longer, while locat-QRSd and locat-LVAT were shorter and locat-LVAT/QRSd was lower than failed sites. There was a positive dose-response relationship between LBBP success likelihood and corrected longit-dist with a cut-off of 26.95 mm, whereas there were negative dose-response relationships of LBBP success likelihood to locat-QRSd, locat-LVAT, and locat-LVAT/QRSd with the cut-offs of 142 ms, 92 ms, and 64.7%, respectively. Downward QRS direction in II/III ECG leads was also associated with successful LBBP. CONCLUSION: Longit-dist, locat-QRSd, locat-LVAT, and locat-LVAT/QRSd were quantitative parameters to guide the selection of lead-implanted sites during LBBP implantation. Quantitative distance and electrocardiographic parameters for lead-implanted site selection to enhance the success likelihood of left bundle branch pacing. LBBP, left bundle branch pacing; Longit-dist, longitudinal distance; CL-apex-dist, distance from contraction line to apex; LBBB, left bundle branch block; IVCD, intraventricular conduction delay; Locat-QRSd, lead-localization-pacing QRS duration; Locat-LVAT, lead-localization-pacing left ventricular activation time; Locat-LVAT/QRSd, lead-localization-pacing LVAT/QRSd ratio.


Subject(s)
Bundle of His , Cardiac Pacing, Artificial , Humans , Cardiac Pacing, Artificial/methods , Bundle-Branch Block/diagnosis , Bundle-Branch Block/therapy , Electrocardiography/methods , Heart Conduction System
6.
Heart Rhythm ; 18(6): 946-953, 2021 06.
Article in English | MEDLINE | ID: mdl-33781981

ABSTRACT

BACKGROUND: Left bundle branch pacing (LBBP) is an emerging physiological pacing modality. However, little is known about pacing at different locations on the left bundle branch (LBB). OBJECTIVE: The purpose of this study was to explore pacing and physiological characteristics associated with different LBBP locations. METHODS: The study included 68 consecutive patients with normal unpaced QRS duration and successful LBBP implantation. Patients were divided into 3 groups according to the paced QRS complex as left bundle branch trunk pacing (LBTP), left posterior fascicular pacing (LPFP), or left anterior fascicular pacing (LAFP). Electrocardiographic (ECG) characteristics, pacing parameters, and fluoroscopic localization were collected and analyzed. RESULTS: There were 17 (25.0%), 35 (51.5%), and 16 (23.5%) patients in the LBTP, LPFP, and LAFP groups, respectively. All subgroups had relatively narrow paced QRS complex (128.6 ± 9.1 ms vs 133.7 ± 11.2 ms vs 134.8 ± 9.6 ms; P = .170), fast left ventricular activation (70.4 ± 9.0 ms vs 70.6 ± 10.2 ms vs 71.0 ± 9.0 ms; P = .986), as well as low and stable pacing thresholds. Delayed right ventricular activation and interventricular dyssynchrony were similar between groups. Fluoroscopic imaging indicated that the lead tip was located most commonly in the basal-middle region of the septum (67.7%), and this was independent of paced QRS morphology group (88.2% vs 57.1% vs 68.8%; P = .106). CONCLUSION: Pacing at different sites of the LBB resulted in similar intraventricular and interventricular electrical synchrony in patients with an intact conduction system. Fluoroscopic imaging alone could not predict specific LBBP paced ECG morphology.


Subject(s)
Bundle of His/anatomy & histology , Bundle-Branch Block/diagnosis , Cardiac Pacing, Artificial/methods , Electrocardiography/methods , Fluoroscopy/methods , Heart Rate/physiology , Bundle of His/physiology , Bundle-Branch Block/physiopathology , Bundle-Branch Block/therapy , Female , Follow-Up Studies , Humans , Male , Middle Aged , Retrospective Studies , Time Factors
7.
Europace ; 22(Suppl_2): ii54-ii60, 2020 12 26.
Article in English | MEDLINE | ID: mdl-33370801

ABSTRACT

AIMS: The present study was to evaluate the feasibility and clinical outcomes of left bundle branch area pacing (LBBAP) in cardiac resynchronization therapy (CRT)-indicated patients. METHODS AND RESULTS: LBBAP was performed via transventricular septal approach in 25 patients as a rescue strategy in 5 patients with failed left ventricular (LV) lead placement and as a primary strategy in the remaining 20 patients. Pacing parameters, procedural characteristics, electrocardiographic, and echocardiographic data were assessed at implantation and follow-up. Of 25 enrolled CRT-indicated patients, 14 had left bundle branch block (LBBB, 56.0%), 3 right bundle branch block (RBBB, 12.0%), 4 intraventricular conduction delay (IVCD, 16.0%), and 4 ventricular pacing dependence (16.0%). The QRS duration (QRSd) was significantly shortened by LBBAP (intrinsic 163.6 ± 29.4 ms vs. LBBAP 123.0 ± 10.8 ms, P < 0.001). During the mean follow-up of 9.1 months, New York Heart Association functional class was improved to 1.4 ± 0.6 from baseline 2.6 ± 0.6 (P < 0.001), left ventricular ejection fraction (LVEF) increased to 46.9 ± 10.2% from baseline 35.2 ± 7.0% (P < 0.001), and LV end-diastolic dimensions (LVEDD) decreased to 56.8 ± 9.7 mm from baseline 64.1 ± 9.9 mm (P < 0.001). There was a significant improvement (34.1 ± 7.4% vs. 50.0 ± 12.2%, P < 0.001) in LVEF in patients with LBBB. CONCLUSION: The present study demonstrates the clinical feasibility of LBBAP in CRT-indicated patients. Left bundle branch area pacing generated narrow QRSd and led to reversal remodelling of LV with improvement in cardiac function. LBBAP may be an alternative to CRT in patients with failure of LV lead placement and a first-line option in selected patients such as those with LBBB and heart failure.


Subject(s)
Cardiac Resynchronization Therapy , Heart Failure , Bundle-Branch Block/diagnosis , Bundle-Branch Block/therapy , Electrocardiography , Feasibility Studies , Heart Failure/diagnosis , Heart Failure/therapy , Humans , Stroke Volume , Treatment Outcome , Ventricular Function, Left
8.
Circ Arrhythm Electrophysiol ; 13(8): e008267, 2020 08.
Article in English | MEDLINE | ID: mdl-32701363

ABSTRACT

BACKGROUND: Left bundle branch pacing (LBBP) is a technique for conduction system pacing, but it often results in right bundle branch block morphology on the ECG. This study was designed to assess simultaneous pacing of the left and right bundle branch areas to achieve more synchronous ventricular activation. METHODS: In symptomatic bradycardia patients, the distal electrode of a bipolar pacing lead was placed at the left bundle branch area via a transventricular-septal approach. This was used to pace the left bundle branch area, while the ring electrode was used to pace the right bundle branch area. Bilateral bundle branch area pacing (BBBP) was achieved by stimulating the cathode and anode in various pacing configurations. QRS duration, delayed right ventricular activation time, left ventricular activation time, and interventricular conduction delay were measured. Pacing stability and short-term safety were assessed at 3-month follow-up. RESULTS: BBBP was successfully performed in 22 of 36 patients. Compared with LBBP, BBBP resulted in greater shortening of QRS duration (109.3±7.1 versus 118.4±5.7 ms, P<0.001). LBBP resulted in a paced right bundle branch block configuration, with a delayed right ventricular activation time of 115.0±7.5 ms and interventricular conduction delay of 34.0±8.8 ms. BBBP fully resolved the right bundle branch block morphology in 18 patients. In the remaining 4 patients, BBBP partially corrected the right bundle branch block with delayed right ventricular activation time decreasing from 120.5±4.7 ms during LBBP to 106.1±4.2 ms during BBBP (P=0.005). CONCLUSIONS: LBBP results in a relatively narrow QRS complex but with an interventricular activation delay. BBBP can diminish the delayed right ventricular activation, producing more physiological ventricular activation. Graphic Abstract: A graphic abstract is available for this article.


Subject(s)
Action Potentials , Bradycardia/therapy , Bundle of His/physiopathology , Cardiac Pacing, Artificial/methods , Heart Rate , Aged , Bradycardia/diagnosis , Bradycardia/physiopathology , Cardiac Pacing, Artificial/adverse effects , Female , Humans , Male , Middle Aged , Recovery of Function , Time Factors , Treatment Outcome , Ventricular Function, Left , Ventricular Function, Right
9.
Zhongguo Gu Shang ; 22(11): 856-8, 2009 Nov.
Article in Chinese | MEDLINE | ID: mdl-20084949

ABSTRACT

OBJECTIVE: To investigate the diagnosis, surgical procedure and clinical outcome of cervical intraspinal benign neoplasm. METHODS: Twenty-two cases confirmed pathologically were reviewed included 16 males and 6 females with an average age of 43.8 years old ranging from 18 to 56 years. Symptoms mainly included neck pain, numbness and weakness of the extremities, urinary and fecal incontinence, pyramid signs, etc. All underwent X-ray, CT and MRI, 11 cases were diagnosed as neurilemomas, 4 neurofibromas, 3 spinal meningiomas, 2 intraspinal cysts and 2 lipomas. The tumors were removed completely in 18 cases, above 60% in 3 cases and 25% with biopsy in 1 case. Cervical stability in 11 cases was restored after removal of tumors. RESULTS: All were followed-up for from 6 to 84 months(means 12.5 months). Symptoms improved in 20 cases and stable in 1 case and worsened in 1 case postoperatively according to JOA scoring system. Two patients recurred and were treated with second surgery. JOA scoring was (6.52 +/- 1.10) before operation, (11.42 +/- 0.79) after operation, there was statically significance (t = 21.38, P < 0.001). The average recover ratio of total was (46.7 +/- 2.46)%, cervical stability was (62.37 +/- 3.58)%, the other methods was (41.21 +/- 4.63)%. The results of JOA were excellent in 18 cases, good in 2, fair in 1 and poor in 1. CONCLUSION: The surgical exairesis for cervical intraspinal benign neoplasm has low post-operative recurrence. The main reason of recurrence is not removed the tumor completely. MRI is regarded the effective method which is helpful in differential diagnosis and surgery guidance.


Subject(s)
Cervical Vertebrae/pathology , Cervical Vertebrae/surgery , Spinal Neoplasms/pathology , Spinal Neoplasms/surgery , Adolescent , Adult , Cervical Vertebrae/physiopathology , Female , Follow-Up Studies , Humans , Male , Middle Aged , Spinal Neoplasms/physiopathology , Spinal Neoplasms/therapy , Treatment Outcome , Young Adult
SELECTION OF CITATIONS
SEARCH DETAIL
...