Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 6 de 6
Filter
Add more filters










Publication year range
1.
J Mater Chem B ; 12(18): 4361-4374, 2024 May 08.
Article in English | MEDLINE | ID: mdl-38639047

ABSTRACT

Repair of large bone defects is one of the clinical problems that have not yet been fully solved. The dynamic balance of bone tissue is regulated by many biological, chemical and physical environmental factors. Simulating the microenvironment of bone tissue in the physiological state through biomimetic materials is an important development direction of tissue engineering in recent years. With the deepening of research, it has been found that when bone tissue is damaged, its surrounding magnetoelectric microenvironment is subsequently destroyed, and providing a magnetoelectric microenvironment in the biomimetic state will be beneficial to promote bone repair. This review describes the piezoelectric effect of natural bone tissue with magnetoelectric stimulation for bone regeneration, provides a detailed account of the historical development of magnetoelectric composites and the current magnetoelectric composites that are most commonly utilized in the field of tissue engineering. Besides, the hypothesized mechanistic pathways through which magnetoelectric composite materials promote bone regeneration are critically examined, including the enhancement of osteogenesis, promotion of cell adhesion and angiogenesis, modulation of bone immunity, and promotion of nerve regeneration.


Subject(s)
Bone Regeneration , Tissue Engineering , Humans , Animals , Osteogenesis/drug effects , Biocompatible Materials/chemistry , Biocompatible Materials/pharmacology
2.
Article in Chinese | WPRIM (Western Pacific) | ID: wpr-1016554

ABSTRACT

@#The standardized workflow of computer-aided static guided implant surgery includes preoperative examination, data acquisition, guide design, guide fabrication and surgery. Errors may occur at each step, leading to irreversible cumulative effects and thus impacting the accuracy of implant placement. However, clinicians tend to focus on factors causing errors in surgical operations, ignoring the possibility of irreversible errors in nonstandard guided surgery. Based on the clinical practice of domestic experts and research progress at home and abroad, this paper summarizes the sources of errors in guided implant surgery from the perspectives of preoperative inspection, data collection, guide designing and manufacturing and describes strategies to resolve errors so as to gain expert consensus. Consensus recommendation: 1. Preoperative considerations: the appropriate implant guide type should be selected according to the patient's oral condition before surgery, and a retaining screw-assisted support guide should be selected if necessary. 2. Data acquisition should be standardized as much as possible, including beam CT and extraoral scanning. CBCT performed with the patient’s head fixed and with a small field of view is recommended. For patients with metal prostheses inside the mouth, a registration marker guide should be used, and the ambient temperature and light of the external oral scanner should be reasonably controlled. 3. Optimization of computer-aided design: it is recommended to select a handle-guided planting system and a closed metal sleeve and to register images by overlapping markers. Properly designing the retaining screws, extending the support structure of the guide plate and increasing the length of the guide section are methods to feasibly reduce the incidence of surgical errors. 4. Improving computer-aided production: it is also crucial to set the best printing parameters according to different printing technologies and to choose the most appropriate postprocessing procedures.

3.
Int J Oral Maxillofac Implants ; 28(3): 767-73, 2013.
Article in English | MEDLINE | ID: mdl-23748307

ABSTRACT

PURPOSE: To compare bone augmentation on pure titanium-machined surfaces and surfaces that have been modified by microarc oxidation (MAO) using titanium caps. MATERIALS AND METHODS: Twenty caps were manufactured from rods of commercially pure titanium. The control group (CG) consisted of 10 titanium caps with machined inner walls. The test group (TG) consisted of 10 titanium caps that were modified by MAO in an electrolyte solution containing calcium phosphate ions. The two types of titanium caps were fixed on the calvaria of 10 New Zealand rabbits. Each rabbit received two different caps. Although each cap was unfilled, the marrow and blood from the wound of the rabbit skulls could penetrate into the caps. After 4 weeks, the rabbits were sacrificed, and the skulls were removed for observation. The zenith of new bone was measured directly after the caps were removed from the skulls; subsequently, the bone volume was calculated by microcomputed tomography. RESULTS: Little bone augmentation could be observed in the CG caps, and the new bone height of the CG group was inconspicuous. In contrast, the new bone extended along the inner walls of the TG caps. The mean height of new bone of the TG group was 2.3 ± 0.28 mm. The mean volume of new bone in the TG group was 18.63 ± 3.80 mm(3). CONCLUSIONS: New bone formation in a titanium cap surface modified by MAO was greater than that of a nonmodified cap. A titanium cap allowed new bone formation on the MAO surface to be observed and is a promising device for bone augmentation. Additionally, this finding suggests that observation through a titanium cap is a feasible method for biomaterial testing in hard tissue.


Subject(s)
Biocompatible Materials , Bone Regeneration/physiology , Dental Arch/surgery , Guided Tissue Regeneration, Periodontal/instrumentation , Titanium , Animals , Calcium Phosphates , Connective Tissue/growth & development , Equipment Design , Guided Tissue Regeneration, Periodontal/methods , Male , Porosity , Rabbits , Random Allocation
4.
J Mater Sci Mater Med ; 24(4): 959-65, 2013 Apr.
Article in English | MEDLINE | ID: mdl-23430332

ABSTRACT

The aim of this study was to evaluate the early osseointegration of implants with the same surface treatment in different implant sites in rabbit tibias after 4 weeks. A total of 42 acid-etched implants were implanted in three different sites in the tibia: group A was 2.08 ± 0.18 mm below epiphyseal line; group B was 7.00 ± 0.61 mm below the epiphyseal line; group C was 13.01 ± 1.26 mm below the epiphyseal line. After 4 weeks, the average bone-to-implant contact (BIC) values were as follows: group A, 40.02 ± 4.82 %; group B, 28.20 ± 5.41 %; group C, 20.76 ± 3.10 %. The BIC measurements yielded statistically significant differences among group A, group B and group C (P < 0.01); group A demonstrated the best osseointegration. In the present study, the different implantation sites in the selected 20-mm area demonstrated different early osseointegration; the sites located 7 ± 1.5 mm below the epiphyseal line were best suited for observing the effectiveness of early osseointegration among the three sites. The statistical results of the early osseointegration of implants are therefore affected by the location of the implant sites in this 20-mm area.


Subject(s)
Osseointegration , Prostheses and Implants , Tibia , Animals , Male , Rabbits , Surface Properties
5.
Int J Oral Maxillofac Implants ; 25(1): 130-6, 2010.
Article in English | MEDLINE | ID: mdl-20209195

ABSTRACT

PURPOSE: To compare the bone responses to a pure titanium machined implant surface and one that has been modified by laser etching and microarc oxidation. MATERIALS AND METHODS: Forty-eight threaded implants with a machined surface were manufactured from rods of commercially pure titanium. The control group consisted of 24 implants with a machined surface. The test group consisted of 24 machined-surface implants that were modified by laser etching and treated by microarc oxidation in an electrolyte solution containing Ca2+ and PO43- ions. The implants were analyzed by energy-dispersive x-ray and scanning electron microscopy. Next, the two types of implants were inserted in the tibiae of 12 New Zealand White rabbits; one of the two tibiae received two control implants and the opposite side received two test implants. After 2, 4, and 6 weeks, the rabbits were sacrificed. Prior to sacrifice, all rabbits were injected with fluorescent-labeled achromycin and calcein. Samples were cut and ground for histomorphologic observation, and the mineralization appositional rate and the osseointegration index were measured and analyzed. RESULTS: Proportional spacing craters were found with a diameter of 100 microm and a depth of 80 to 100 microm at intervals of 100 microm around the test surface, and a porous titanium dioxide coating on the surface with pores of 1 to 5 micro in diameter was also produced. Carbon, oxygen, calcium, and phosphonium were detected by electronic probe. The ratio of calcium to phosphonium was 1.418, and the crystal structure of x-ray diffractive patterns indicated pure anatase phases. Compared with the control samples, the mineralization ratio and the osseointegration index of the bone around the test implants were higher (P = .00). CONCLUSIONS: The porous titanium dioxide coating produced by laser etching and microarc oxidation treatment improved the bone response versus that seen around machined titanium implants and enhanced the bone formation rate. It was concluded that the surface chemistry and topography, either separately or together, play an important role in the bone response to implants.


Subject(s)
Dental Implants , Osseointegration , Titanium , Animals , Calcification, Physiologic , Coated Materials, Biocompatible , Dental Etching , Dental Polishing , Implants, Experimental , Lasers, Solid-State , Male , Photoelectron Spectroscopy , Rabbits , Surface Properties , Tibia/surgery
6.
J Mater Sci Mater Med ; 20(8): 1721-8, 2009 Aug.
Article in English | MEDLINE | ID: mdl-19291368

ABSTRACT

The aim of the study was to evaluate early osseointegration of the laser-treated and acid-etched implant surface after the installation in rabbit tibias for 4 weeks. A total of 56 screw-shaped implants were grouped as follows: group A: implants were turned surface; group B: implants were laser-treated surface; group C: implants were acid-etched; group D: Implants were laser-treated and acid-etched surface. After 4 weeks, the removal torques were: group A: 13.21 +/- 11.30 Ncm; group B: 29.73 +/- 8.32 Ncm; group C: 30.31 +/- 9.45 Ncm; group D: 35.76 +/- 7.58 Ncm; The averages of bone-to-implant contact (BIC) were as follows: group A: 27.30 +/- 6.55%; group B: 38.00 +/- 8.56%; group C: 42.71 +/- 8.48%; group D: 49.71 +/- 9.21%. The removal torque and bone-to-implant contact measurements yielded statistically significant differences between the treated groups and turned group (P < 0.05); The laser-treated and acid-etched surface achieved higher Bone-to-Implant Contact than the laser-treated surface (P < 0.05), but there was no statistically significant difference between the laser-treated and acid-etched surface and the acid-etched surface in bone-to-implant contact (P > 0.05). In the present study, it was concluded that the laser-treated and acid-etched implants had good osteoconductivity and was a potential material for dental implantation.


Subject(s)
Acid Etching, Dental , Dental Implants , Lasers , Osseointegration/physiology , Acid Etching, Dental/adverse effects , Acid Etching, Dental/methods , Acids/pharmacology , Animals , Bone Screws , Cell Adhesion , Dental Etching/methods , Implants, Experimental , Rabbits , Surface Properties , Time Factors
SELECTION OF CITATIONS
SEARCH DETAIL
...