Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 2 de 2
Filter
Add more filters










Database
Language
Publication year range
1.
J Neurosci Methods ; 311: 122-132, 2019 01 01.
Article in English | MEDLINE | ID: mdl-30300699

ABSTRACT

BACKGROUND: Recent advancements in simultaneous multi-slice (SMS) imaging techniques have enabled whole-brain resting-state fMRI (rs-fMRI) scanning at sub-second temporal resolution, providing spectral ranges much wider than the typically used range of 0.01-0.1 Hz. However, the advantages of this accelerated acquisition for rs-fMRI have not been evaluated. NEW METHOD: In this study, we used SMS Echo Planar Imaging (EPI) to probe whole-brain functional connectivity with a short repetition time (TR = 350 ms) and compared it with standard EPI with a longer TR of 2000 ms. We determined the effect of scan length and investigated the temporal filtration strategies that optimize results based on metrics of signal-noise separation and test-retest reliability using both seed-based and independent component analysis (ICA). RESULTS: We found that use of either the entire frequency range of 0.01-1.4 Hz or the entire frequency range with the exclusion of typical cardiac and respiratory frequency values tended to provide the best functional connectivity maps. COMPARISON WITH EXISTING METHODS: We found that the SMS-acquired rs-fMRI scans had improved the signal-noise separation, while preserving the same level of test-retest reliability compared to conventional EPI, and enabled the detection of reliable functional connectivity networks with scan times as short as 3 min. CONCLUSIONS: Our findings suggest that whole-brain rs-fMRI studies may benefit from the increased temporal resolution enabled by the SMS-EPI acquisition, leading to drastic scan time reductions, which in turn should enable the more widespread use of rs-fMRI in clinical research protocols.


Subject(s)
Brain Mapping/methods , Brain/diagnostic imaging , Echo-Planar Imaging , Magnetic Resonance Imaging , Adult , Brain/anatomy & histology , Brain/physiology , Brain Mapping/instrumentation , Humans , Image Processing, Computer-Assisted , Middle Aged , Reproducibility of Results , Signal-To-Noise Ratio
2.
IEEE Trans Med Imaging ; 35(8): 1824-36, 2016 08.
Article in English | MEDLINE | ID: mdl-26915118

ABSTRACT

Simultaneous Multi-Slice (SMS) magnetic resonance imaging (MRI) is a rapidly evolving technique for increasing imaging speed. Controlled aliasing techniques utilize periodic undersampling patterns to help mitigate the loss in signal-to-noise ratio (SNR) in SMS MRI. To evaluate the performance of different undersampling patterns, a quantitative description of the image SNR loss is needed. Additionally, eddy current effects in echo planar imaging (EPI) lead to slice-specific Nyquist ghosting artifacts. These artifacts cannot be accurately corrected for each individual slice before or after slice-unaliasing. In this work, we propose a hybrid-space sensitivity encoding (SENSE) reconstruction framework for SMS MRI by adopting a three-dimensional representation of the SMS acquisition. Analytical SNR loss maps are derived for SMS acquisitions with arbitrary phase encoding undersampling patterns. Moreover, we propose a matrix-decoding correction method that corrects the slice-specific Nyquist ghosting artifacts in SMS EPI acquisitions. Brain images demonstrate that the proposed hybrid-space SENSE reconstruction generates images with comparable quality to commonly used split-slice-generalized autocalibrating partially parallel acquisition reconstruction. The analytical SNR loss maps agree with those calculated by a Monte Carlo based method, but require less computation time for high quality maps. The analytical maps enable a fair comparison between the performances of coherent and incoherent SMS undersampling patterns. Phantom and brain SMS EPI images show that the matrix-decoding method performs better than the single-slice and slice-averaged Nyquist ghosting correction methods under the hybrid-space SENSE reconstruction framework.


Subject(s)
Magnetic Resonance Imaging , Artifacts , Brain , Echo-Planar Imaging , Humans , Phantoms, Imaging , Signal-To-Noise Ratio
SELECTION OF CITATIONS
SEARCH DETAIL
...