Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 1 de 1
Filter
Add more filters










Database
Language
Publication year range
1.
Shanghai Kou Qiang Yi Xue ; 20(6): 590-4, 2011 Dec.
Article in Chinese | MEDLINE | ID: mdl-22241305

ABSTRACT

PURPOSE: To evaluate the stability of the miniscrew on different loading time as orthodontic anchorage. METHODS: 2 healthy adult male Beagle dogs were used in this study. 48 mini-implants were implanted into the maxilla and mandible of the dogs. The miniscrews were divided into 8 different groups,1 group was loaded 0g as control group and the others were loaded 200g forces as experimental groups. 200g forces were loaded on the corresponding mini-implant anchorages immediately after implantation and at the time of 1w,2w,3w,4w,5w and 6w after implantation. The dogs were sacrificed at 12w after implantation. Histological progresses of implant-bone interfaces was examined with light microscope. Blue deposition and contact ratio were calculated and analyzed using SPSS13.0 software package. RESULTS: Fibrous and osseous-integration was noted in the interface, there was no significant difference in bone deposition ratio and bone contact ratio. CONCLUSION: Different force loading time does not affect the stability of the mini-implant anchorage.


Subject(s)
Orthodontic Anchorage Procedures , Osseointegration , Animals , Bone Screws , Dogs , Male , Mandible , Maxilla
SELECTION OF CITATIONS
SEARCH DETAIL
...