Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 3 de 3
Filter
Add more filters










Database
Publication year range
1.
J Clin Monit Comput ; 34(1): 151-159, 2020 Feb.
Article in English | MEDLINE | ID: mdl-30903412

ABSTRACT

To investigate the effect of positive end-expiratory pressure (PEEP) guided by transpulmonary pressure or with maximum oxygenation-directed PEEP on lung injury in a porcine model of acute respiratory distress syndrome (ARDS). The porcine model of ARDS was induced in 12 standard pigs by intratracheal infusion with normal saline. The pigs were then randomly divided into two groups who were ventilated with the lung-protective strategy of low tidal volume (VT) (6 ml/kg), using different methods to titrate PEEP level: transpulmonary pressure (TP group; n = 6) or maximum oxygenation (MO group; n = 6). Gas exchange, pulmonary mechanics, and hemodynamics were determined and pulmonary inflammatory response indices were measured after 4 h of ventilation. The titrated PEEP level in the TP group (6.12 ± 0.89 cmH2O) was significantly lower than that in the MO group (11.33 ± 2.07 cmH2O) (P < 0.05). The PaO2/FiO2 (P/F) after PEEP titration both improved in the TP and MO groups as compared with that at T0 (when the criteria for ARDS were obtained). The P/F in the TP group did not differ significantly from that in the MO group during the 4 h of ventilation (P > 0.05). Respiratory system compliance and lung compliance were significantly improved in the TP group compared to the MO group (P < 0.05). The VD/VT in the TP group was significantly lower than that in the MO group after 4 h of ventilation (P < 0.05). Central venous pressure increased and the cardiac index decreased significantly in the MO group as compared with the TP group (P < 0.05), whereas oxygen delivery did not differ significantly between the groups (P > 0.05). The pulmonary vascular permeability index and the extravascular lung water index in the TP group were significantly lower than those in the MO group (P < 0.05). The TP group had a lower lung wet to dry weight ratio, lung injury score, and MPO, TNF-, and IL-8 concentrations than the MO group (P < 0.05). In summary, in a pig model of ARDS, ventilation with low VT and transpulmonary pressure-guided PEEP adjustment was associated with improved compliance, reduced dead space ventilation, increased cardiac output, and relieved lung injury, as compared to maximum oxygenation-guide PEEP adjustment.


Subject(s)
Lung Compliance/physiology , Lung Injury/therapy , Positive-Pressure Respiration/methods , Respiratory Distress Syndrome/therapy , Tidal Volume , Animals , Cardiac Output/physiology , Extravascular Lung Water , Hemodynamics , Inflammation , Lung/physiology , Permeability , Pulmonary Edema , Pulmonary Gas Exchange/physiology , Respiratory Mechanics/physiology , Swine
3.
Zhonghua Yi Xue Za Zhi ; 95(39): 3168-72, 2015 Oct 20.
Article in Chinese | MEDLINE | ID: mdl-26814111

ABSTRACT

OBJECTIVE: To assess the effect of mehanical ventilation (MV) guided by transpulmonary pressure (Ptp) on respiratory mechanics and gas exchange in severe acute pancreatitis patient with intraabdominal hypertension. METHODS: Twelve severe acute pancreatitis patient with intraabdominal hypertension and acute respiratory distress syndrome(ARDS) underwent mechanical ventilation were involved from Jan to Dec 2013. PEEP levels were set to achieve a Ptp of 0 to 10 cm of water at end expiration. We also limited tidal volume to keep Ptp at less than 25 cm of water at end inspiration. Respiratory mechanics and gas-exchange were measured. RESULTS: Plat pressure (Pplat) increased and the compliance of chest wall (Ccw) decreased when intraabdominal pressure (IAP) increased. Pplat correlated with IAP positively (r2=0.741 9, P<0.05) and Ccw correlated with IAP negtively (r2=0.722 2, P<0.05), respectively.There were not corrletions between IAP and end-expiratory Ptp (Ptp-e) and end-inspiratory Ptp (Ptp-i) (P>0.05). Compared with baseline, after guiding MV with Ptp, the Level of PEEP (14.6±4.2) cmH2O vs (8.3±2.0) cmH2O, and Ptp-e (1.5±0.5) cmH2O vs (-2.3±1.4) cmH2O increased (P<0.05) and Ptp-i did not increase significantly (P>0.05). Ptp-e correlated with PEEP (r2=0.549, P<0.05) and end-expiratory esophageal pressure (Pes-e) (r2=0.260, P<0.05). Ptp-i correlated with Pplat (r2=0.523, P<0.05) and end-inspiratory esophageal pressure (Pes-i) (r2=0.231, P<0.05), but did not correlate with Tidal volume(VT) (r2=0.052 4, P>0.05). Compared with baseline, lung compliance (CL) (48.1±10.3) cmH2O vs (25.7±6.4) cmH2O and oxygenation index (PaO2/FiO2) (235±48) mmHg vs (160±35) mmHg improved obviously (P<0.05), dead space fraction (VD/VT) (0.48±0.07) vs (0.59±0.06) decreased (P<0.05), but Ccw and respiratory compliance(Cr) didn't improve (P>0.05). CONCLUSIONS: Transpulmonary pressure-directed mechanical ventilation in ARDS secondary to severe acute pancreatitis patient with intraabdominal hypertension could not only recruit the collapsed alveoli, improve lung compliance, increase oxygenation index and decrease dead space ventilation but also monitor lung stress to avoid alveoli overinflation, which might be lung protective.


Subject(s)
Intra-Abdominal Hypertension , Positive-Pressure Respiration , Blood Gas Analysis , Humans , Lung , Lung Compliance , Pancreatitis , Patient Compliance , Pressure , Pulmonary Alveoli , Respiratory Distress Syndrome , Respiratory Mechanics , Tidal Volume
SELECTION OF CITATIONS
SEARCH DETAIL
...