Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 2 de 2
Filter
Add more filters










Database
Language
Publication year range
1.
Europace ; 25(4): 1379-1391, 2023 04 15.
Article in English | MEDLINE | ID: mdl-36881791

ABSTRACT

AIMS: Pulmonary vein isolation using radiofrequency ablation is an effective treatment option for patients with symptomatic atrial fibrillation (AF). Application of high power over a short period of time (HPSD) is reported to create more efficient lesions and may prevent collateral thermal oesophageal injury. This study aims to compare efficacy and safety of two different HPSD ablation approaches using different ablation index settings. METHODS AND RESULTS: Consecutive patients undergoing AF ablation with HPSD (50 W; ablation index-guided) using the ThermoCool SmartTouch SF catheter were included. Patients were grouped by ablation protocol: ablation with target ablation index (AI) of 400 on the anterior left atrial wall vs. 300 at the posterior left atrial wall (AI 400/300) or AI 450/350 was performed upon the operator's preference and compared. Peri-procedural parameters and complications were recorded, and incidences of endoscopically detected thermal oesophageal lesions (EDEL) analysed. Recurrence rates after a mean follow-up of 25 ± 7 months and reconnection patterns in patients undergoing redo procedures were investigated. A total of 795 patients (67 ± 10 years; 58% male; 48% paroxysmal AF) underwent a first AF ablation with HPSD (211 in group AI 400/300 and 584 in group 450/350). Median procedure time was 82.9 ± 24.6 min with longer ablation times in patients with target AI 400/300 due to higher intraprocedural reconnection rates, increased box lesions, and additional right atrial isthmus ablations. EDEL rates among target AI 400/300 procedures were significantly lower (3% vs. 7%; P = 0.019). Correspondingly, AI 450/350 was the strongest independent predictor of post-ablation EDEL (OR 4.799, CI 1.427-16.138, P = 0.011). Twelve-month (76% vs. 76%; P = 0.892) and long-term ablation single procedure success (68% vs. 71%; log-rank P = 0.452) after a mean of 25 ± 7 months were comparable among both target AI groups; however, long-term success was significantly higher for paroxysmal AF compared to persistent AF (12 months: 80% vs. 72%; P = 0.010; end of follow-up: 76% vs. 65%; log-rank P = 0.001). One hundred three patients (16%) underwent a redo procedure during follow-up documented comparable pulmonary vein (PV) reconnection among groups. Multivariate predictors of AF recurrence were age, left atrium (LA) size, persistent AF, and extra-PV ablation targets. CONCLUSION: High-power short-duration AF ablation with target AI of 400 for non-posterior wall and 300 for posterior wall lesions resulted in comparable long-term results compared to higher AI (450/350) ablations with significantly lower risk for thermal oesophageal lesions. Older age, larger LA size, persistent AF, and extra-PV ablation targets were identified in a multivariate analysis as independent risk factors for recurrences of atrial arrhythmias.


Subject(s)
Atrial Fibrillation , Catheter Ablation , Pulmonary Veins , Humans , Male , Female , Atrial Fibrillation/diagnosis , Atrial Fibrillation/surgery , Atrial Fibrillation/etiology , Follow-Up Studies , Treatment Outcome , Esophagus/surgery , Artificial Intelligence , Catheter Ablation/adverse effects , Catheter Ablation/methods , Pulmonary Veins/surgery , Recurrence
2.
Parasitol Res ; 103 Suppl 1: S45-53, 2008 Dec.
Article in English | MEDLINE | ID: mdl-19030885

ABSTRACT

In 1999, there was the large outbreak of West Nile fever (WNF) in Southern Russia (>500 cases in the Volgograd Province). In 2000-2004, the WNF incidence rate decreased steadily to zero, but a new outbreak occurred in 2007 (64 cases). The analysis of historical climate data for Volgograd from 1900 to present showed that the years 1999 and 2007 were the hottest ones due to a very mild "winter" (Dec.-Mar.) and a hot "summer" (June-Sep.). There are up to 15 potential WNF vectors in Volgograd, but only Culex pipiens and Culex modestus are abundant in late summer, both in urban and rural settings. Only these species are naturally attracted to and feed on both humans and birds. The RNA of pathogenic WN virus genovariant was found by reverse transcriptase polymerase chain reaction only in Culex mosquitoes at the infection rate of about 0.04%. So these species may be considered as potential WNF "bridge vectors" between birds and humans as well as main vectors in sylvatic avain cycle. Their abundance in an epidemic season was higher in the years with a mild winter and a hot summer, so this phenomenon may serve as a connecting link between a climate and WNF epidemiology. These findings give some hints on the predisposing factors for WNF epidemic as well as the possibility to predict WNF outbreaks in the temperate climate zones.


Subject(s)
Climate , Culex/virology , Disease Outbreaks , Disease Vectors , West Nile Fever/epidemiology , Animals , Culex/growth & development , Humans , Incidence , Population Dynamics , Reverse Transcriptase Polymerase Chain Reaction , Russia/epidemiology , West Nile virus/isolation & purification
SELECTION OF CITATIONS
SEARCH DETAIL
...