Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 2 de 2
Filter
Add more filters










Database
Language
Publication year range
1.
J Environ Radioact ; 134: 99-108, 2014 Aug.
Article in English | MEDLINE | ID: mdl-24699403

ABSTRACT

In this work, Ni(OH)2-loaded Amberlite IR120 (Ni-MA) and Co(OH)2-loaded Amberlite IR120 (Co-MA) resins were prepared, characterized and applied for UO2(2+) removal from aqueous solutions. The adsorption characteristics were investigated in a batch system with respect to effect of contact time, pH, equilibrium isotherms and removal kinetics data. The results indicated that the UO2(2+) could be efficiently removed from aqueous solutions at pH = 3.5 using Ni-MA and Co-MA resins. The maximum adsorption capacities for the UO2(2+) of Ni-MA and Co-MA were found to be 439 mg/g and 451 mg/g respectively. The equilibrium data fit well with the Langmuir adsorption isotherm. Kinetics study showed that the adsorption process was fast and reached equilibrium within 60 min and the kinetics data fit well with pseudo-second order and intra-particle diffusion models for both resins. The adsorption mechanism has been proposed and discussed. It was found that both Ni-MA and Co-MA resins could be used effectively for UO2(2+) removal from aqueous solutions.


Subject(s)
Hydroxides/chemistry , Resins, Synthetic/chemistry , Uranium/chemistry , Adsorption
2.
Talanta ; 118: 147-55, 2014 Jan.
Article in English | MEDLINE | ID: mdl-24274282

ABSTRACT

Novel uranyl selective polymeric membrane electrodes were prepared using three different low-cost and commercially available Cyanex extractants namely, bis(2,4,4-trimethylpentyl) phosphinic acid [L1], bis(2,4,4-trimethylpentyl) monothiophosphinic acid [L2] and bis(2,4,4-trimethylpentyl) dithiophosphinic acid [L3]. Optimization and performance characteristics of the developed Cyanex based polymer membrane electrodes were determined. The influence of membrane composition (e.g., amount and type of ionic sites, as well as type of plasticizer) on potentiometric responses of the prepared membrane electrodes was studied. Optimized Cyanex-based membrane electrodes exhibited Nernstian responses for UO2(2+) ion over wide concentration ranges with fast response times. The optimized membrane electrodes based on L1, L2 and L3 exhibited Nernstian responses towards uranyl ion with slopes of 29.4, 28.0 and 29.3 mV decade(-1), respectively. The optimized membrane electrodes based on L1-L3 showed detection limits of 8.3 × 10(-5), 3.0 × 10(-5) and 3.3 × 10(-6) mol L(-1), respectively. The selectivity studies showed that the optimized membrane electrodes exhibited high selectivity towards UO2(2+) ion over large number of other cations. Membrane electrodes based on L3 exhibited superior potentiometric response characteristics compared to those based on L1 and L2 (e.g., widest linear range and lowest detection limit). The analytical utility of uranyl membrane electrodes formulated with Cyanex extractant L3 was demonstrated by the analysis of uranyl ion in different real samples for nuclear safeguards verification purposes. The results obtained using direct potentiometry and flow-injection methods were compared with those measured using the standard UV-visible and inductively coupled plasma spectroscopic methods.


Subject(s)
Ion-Selective Electrodes , Membranes, Artificial , Nuclear Power Plants , Organothiophosphorus Compounds/chemistry , Polymers/chemistry , Uranium Compounds/analysis , Flow Injection Analysis , Hydrogen-Ion Concentration , Potentiometry , Spectrophotometry, Ultraviolet
SELECTION OF CITATIONS
SEARCH DETAIL
...