Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 12 de 12
Filter
Add more filters










Main subject
Publication year range
1.
Phys Rev E ; 106(4-2): 045211, 2022 Oct.
Article in English | MEDLINE | ID: mdl-36397600

ABSTRACT

A strong quasistationary magnetic field is generated in hollow targets with curved internal surface under the action of a relativistically intense picosecond laser pulse. Experimental data evidence the formation of quasistationary strongly magnetized plasma structures decaying on a hundred picoseconds timescale, with the magnetic field strength of the kilotesla scale. Numerical simulations unravel the importance of transient processes during the magnetic field generation and suggest the existence of fast and slow regimes of plasmoid evolution depending on the interaction parameters. The proposed setup is suited for perspective highly magnetized plasma application and fundamental studies.

2.
Sci Rep ; 12(1): 13734, 2022 Aug 12.
Article in English | MEDLINE | ID: mdl-35962017

ABSTRACT

Optical generation of kilo-tesla scale magnetic fields enables prospective technologies and fundamental studies with unprecedentedly high magnetic field energy density. A question is the optimal configuration of proposed setups, where plenty of physical phenomena accompany the generation and complicate both theoretical studies and experimental realizations. Short laser drivers seem more suitable in many applications, though the process is tangled by an intrinsic transient nature. In this work, an artificial neural network is engaged for unravelling main features of the magnetic field excited with a picosecond laser pulse. The trained neural network acquires an ability to read the magnetic field values from experimental data, extremely facilitating interpretation of the experimental results. The conclusion is that the short sub-picosecond laser pulse may generate a quasi-stationary magnetic field structure living on a hundred picosecond time scale, when the induced current forms a closed circuit.

3.
Sci Rep ; 12(1): 4784, 2022 Mar 21.
Article in English | MEDLINE | ID: mdl-35315434

ABSTRACT

In the past years, the interest in the laser-driven acceleration of heavy ions in the mass range of [Formula: see text] has been increasing due to promising application ideas like the fission-fusion nuclear reaction mechanism, aiming at the production of neutron-rich isotopes relevant for the astrophysical r-process nucleosynthesis. In this paper, we report on the laser acceleration of gold ions to beyond 7 MeV/u, exceeding for the first time an important prerequisite for this nuclear reaction scheme. Moreover, the gold ion charge states have been detected with an unprecedented resolution, which enables the separation of individual charge states up to 4 MeV/u. The recorded charge-state distributions show a remarkable dependency on the target foil thickness and differ from simulations, lacking a straight-forward explanation by the established ionization models.

4.
Opt Express ; 29(21): 34378-34393, 2021 Oct 11.
Article in English | MEDLINE | ID: mdl-34809230

ABSTRACT

Off-axis parabolic telescopes are rarely used in high-intensity, high-energy lasers, despite their favorable properties for beam transport such as achromatism, low aberrations and the ability to handle high peak intensities. One of the major reasons for this is the alignment procedure which is commonly viewed as complicated and time consuming. In this article, we revisit off-axis parabolic telescopes in the context of beam transport in high-intensity laser systems and present a corresponding analytical model. Based on that, we propose a suitable setup that enables fast and repeatable alignment for everyday operation.

5.
Opt Lett ; 43(16): 3909-3912, 2018 Aug 15.
Article in English | MEDLINE | ID: mdl-30106914

ABSTRACT

One order of magnitude energy enhancement of the target surface electron beams with central energy at 11.5 MeV is achieved by using a 200 TW, 500 fs laser at an incident angle of 72° with a prepulse intensity ratio of 5×10-6. The experimental results demonstrate the scalability of the acceleration process to high electron energy with a longer (sub-picosecond) laser pulse duration and a higher laser energy (120 J). The total charge of the beam is 400±20 pC(E>2.7 MeV). Such a high orientation and mono-energetic electron jet would be a good method to solve the problem of the large beam divergence in fast ignition schemes and to increase the laser energy deposition on the target core.

6.
Nat Commun ; 9(1): 423, 2018 01 29.
Article in English | MEDLINE | ID: mdl-29379024

ABSTRACT

Often, the interpretation of experiments concerning the manipulation of the energy distribution of laser-accelerated ion bunches is complicated by the multitude of competing dynamic processes simultaneously contributing to recorded ion signals. Here we demonstrate experimentally the acceleration of a clean proton bunch. This was achieved with a microscopic and three-dimensionally confined near critical density plasma, which evolves from a 1 µm diameter plastic sphere, which is levitated and positioned with micrometer precision in the focus of a Petawatt laser pulse. The emitted proton bunch is reproducibly observed with central energies between 20 and 40 MeV and narrow energy spread (down to 25%) showing almost no low-energetic background. Together with three-dimensional particle-in-cell simulations we track the complete acceleration process, evidencing the transition from organized acceleration to Coulomb repulsion. This reveals limitations of current high power lasers and viable paths to optimize laser-driven ion sources.

7.
Phys Rev Lett ; 118(25): 255003, 2017 Jun 23.
Article in English | MEDLINE | ID: mdl-28696732

ABSTRACT

We apply Fourier-transform spectral interferometry (FTSI) to study the interaction of intense laser pulses with ultrathin targets. Ultrathin submicrometer-thick solid CH targets were shot at the PHELIX laser facility with an intensity in the mid to upper 10^{19} W/cm^{2} range using an innovative double-pulse structure. The transmitted pulse structure was analyzed by FTSI and shows a transition from a relativistic transparency-dominated regime for targets thinner than 500 nm to a hole-boring-dominated laser-plasma interaction for thicker targets. The results also confirm that the inevitable preplasma expansion happening during the rising slope of the pulse, a few picoseconds before the maximum of the pulse is reached, cannot be neglected and plays a dominant role in laser-plasma interaction with ultrathin solid targets.

8.
Phys Rev Lett ; 116(20): 205002, 2016 May 20.
Article in English | MEDLINE | ID: mdl-27258872

ABSTRACT

We present a study of laser-driven ion acceleration with micrometer and submicrometer thick plastic targets. Using laser pulses with high temporal contrast and an intensity of the order of 10^{20} W/cm^{2} we observe proton beams with cutoff energies in excess of 85 MeV and particle numbers of 10^{9} in an energy bin of 1 MeV around this maximum. We show that applying the target normal sheath acceleration mechanism with submicrometer thick targets is a very robust way to achieve such high ion energies and particle fluxes. Our results are backed with 2D particle in cell simulations furthermore predicting cutoff energies above 200 MeV for acceleration based on relativistic transparency. This predicted regime can be probed after a few technically feasible adjustments of the laser and target parameters.

9.
Opt Express ; 20(23): 25391-9, 2012 Nov 05.
Article in English | MEDLINE | ID: mdl-23187356

ABSTRACT

Experimental results of a two-stage Ni-like Ag soft X-ray laser operated in a seed-amplifier configuration are presented. Both targets were pumped applying the double-pulse grazing incidence technique with intrinsic travelling wave excitation. The injection of the seed X-ray laser into the amplifier target was realized by a spherical mirror. The results show amplification of the seed X-ray laser and allow for a direct measurement of the gain lifetime. The experimental configuration is suitable for providing valuable input for computational simulations.

10.
Opt Express ; 20(9): 10128-37, 2012 Apr 23.
Article in English | MEDLINE | ID: mdl-22535105

ABSTRACT

The influence on Nickel-like Molybdenum soft-x-ray laser performance and stability of a low energy laser prepulse arriving prior to the main laser pumping pulses is experimentally investigated. A promising regime for 10 Hz operation has been observed. A four times increase in soft-x-ray laser operation time with a same target surface is demonstrated. This soft-x-ray laser operation mode corresponds to an optimum delay between the prepulse and the main pulses and to a prepulse energy greater than 20 mJ. We also show that this regime is not associated with a weaker degradation of the target or any reduced ablation rate. Therefore the role of preplasma density gradient in this effect is discussed.


Subject(s)
Lasers , Computer-Aided Design , Equipment Design , Equipment Failure Analysis , X-Rays
11.
Opt Lett ; 32(2): 139-41, 2007 Jan 15.
Article in English | MEDLINE | ID: mdl-17186043

ABSTRACT

We report the near-field imaging characterization of a 10 Hz Ni-like 18.9 nm molybdenum soft-x-ray laser pumped in a grazing incidence pumping (GRIP) geometry with a table-top laser driver. We investigate the effect of varying the GRIP angle on the spatial behavior of the soft-x-ray laser source. After multiparameter optimization, we were able to find conditions to generate routinely a high-repetition-rate soft-x-ray laser with an energy level of up to 3 microJ/pulse and to 6x10(17) photons/s/mm2/mrad2/(0.1% bandwidth) average brightness and 1x10(28) photons/s/mm2/mrad2/(0.1% bandwidth) peak brightness.

12.
Opt Express ; 15(15): 9486-93, 2007 Jul 23.
Article in English | MEDLINE | ID: mdl-19547296

ABSTRACT

A soft x-ray laser from Ni-like Mo, pumped in grazing incidence (GRIP), is analyzed with regard to high repetition rate operation. Reliable lasing is obtained, but with significant energy fluctuations attributed mainly to beam pointing jitter from the pump laser. Two modes of operation are compared: continuously moving target and stationary target. With a moving target the soft X-ray output is constant on average, whereas the repeated use of the same target position leads to a pulse energy which increases for several tens of shots. This effect might be caused by improved guiding of the pump laser in the formed groove and the removal, through laser ablation, of the oxide layer on the target surface.

SELECTION OF CITATIONS
SEARCH DETAIL
...