ABSTRACT
A 25-year-old female with idiopathic pulmonary arterial hypertension (PAH), who had a Hickman catheter implanted for continuous intravenous epoprostenol infusion, was admitted to the clinic after inadvertently cutting the catheter with nail scissors during a routine dressing change. Approximately 7â cm of the external segment of the Hickman catheter remained intact, with the distal end knotted by paramedics. A decision was made to repair the damaged Hickman catheter. However, it was discovered that its lumen was completely occluded by thrombosis. Therefore, catheter patency was mechanically restored using a 0.035-inch stiff guidewire in a sterile operating theatre setting, under fluoroscopy guidance. Successful aspiration and catheter flushing were achieved. Continuity of the Hickman catheter was then restored using a repair kit (Bard Access Systems) as per the manufacturer's instructions, with no visible leakage thereafter. Epoprostenol infusion through the Hickman catheter was resumed 24â h later, and the patient was discharged in good general condition two days afterward.
ABSTRACT
BACKGROUND: Atrial fibrillation (AF) is the most common cardiac arrhythmia, characterized by an increased risk of thromboembolic complications that can be markedly reduced with anticoagulation. There is a paucity of studies assessing the total prevalence of AF in national populations. AIMS: To assess the nationwide prevalence of AF in a population of adults ≥65 old and to determine the impact of duration of electrocardiogram (ECG) monitoring on the number of newly detected AF episodes. METHODS: The NOMED-AF study (ClinicalTrials.gov; NCT: 0324347) was a cross-sectional study performed on a nationally representative random sample of 3014 Polish citizens 65 years or older. Final estimates were adjusted to the national population. All participants underwent up to 30 days of continuous ECG monitoring. Total AF prevalence was diagnosed based on the patient's medical records or the presence of AF in ECG monitoring. RESULTS: The prevalence of AF in the Polish population ≥65 years was estimated as 19.2% (95% confidence interval [CI], 17.9%-20.6%). This included 4.1% (95% CI, 3.5%-4.8%) newly diagnosed cases and 15.1% (95% CI, 13.9%-16.3%) previously diagnosed cases and consisted of 10.8% (95% CI, 9.8%-11.9%) paroxysmal AF and 8.4% (95% CI, 7.5%-9.4%) persistent/permanent AF. The incidence of all paroxysmal AF events as a function of ECG monitoring duration increased from 1.9% (95% CI, 1.4%-2.6%) at 24 hours to 6.2% (95% CI, 5.3%-7.2%) at 4 weeks. CONCLUSIONS: The prevalence of AF in elderly adults is higher than estimated based on medical records only. Four weeks of monitoring compared to 24-hour ECG Holter allow detection of 7-fold more cases of previously undiagnosed paroxysmal AF.