Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 2 de 2
Filter
Add more filters










Database
Language
Publication year range
1.
Phys Rev E Stat Nonlin Soft Matter Phys ; 83(6 Pt 2): 066405, 2011 Jun.
Article in English | MEDLINE | ID: mdl-21797496

ABSTRACT

The magneto-Rayleigh-Taylor instability (MRT) of a finite slab is studied analytically using the ideal MHD model. The slab may be accelerated by an arbitrary combination of magnetic pressure and fluid pressure, thus allowing an arbitrary degree of anisotropy intrinsic to the acceleration mechanism. The effect of feedthrough in the finite slab is also analyzed. The classical feedthrough solution obtained by Taylor in the limit of zero magnetic field, the single interface MRT solution of Chandrasekhar in the limit of infinite slab thickness, and Harris' stability condition on purely magnetic driven MRT, are all readily recovered in the analytic theory as limiting cases. In general, we find that MRT retains robust growth if it exists. However, feedthrough may be substantially reduced if there are magnetic fields on both sides of the slab, and if the MRT mode invokes bending of the magnetic field lines.

2.
Rev Sci Instrum ; 79(9): 093512, 2008 Sep.
Article in English | MEDLINE | ID: mdl-19044418

ABSTRACT

Soft metal gaskets (indium and silver) were used to reduce contact resistance between the wire and the electrode in an aluminum wire Z pinch by more than an order of magnitude over the best weighted contact case. Clamping a gasket over a Z-pinch wire compresses the wire to the electrode with a greater normal force than possible with wire weights. Average contact resistance was reduced from the range of 100-3000 Omega (depending on wire weight mass) to 1-10 Omega with soft metal gaskets. Single wire experiments (13 microm Al 5056) on a 16 kA, 100 kV Marx bank showed an increase in light emission (97%) and emission volume (100%) of the plasma for the reduced contact resistance cases. The measured increases in plasma volume and light emission indicate greater energy deposition in the ablated wire. Additionally, dual-wire experiments showed plasma edge effects were significantly decreased in the soft metal gasket contact case. The average height of the edge effects was reduced by 51% and the width of the edge effects was increased by 40%, thus the gasket contact case provided greater axial uniformity in the plasma expansion profile of an individual wire.

SELECTION OF CITATIONS
SEARCH DETAIL
...