Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 7 de 7
Filter
1.
Cochlear Implants Int ; 23(5): 291-299, 2022 09.
Article in English | MEDLINE | ID: mdl-35577761

ABSTRACT

The BONEBRIDGE is a partially implantable, transcutaneous bone conduction device that can be used to treat conductive or mixed mild-to-moderate hearing loss in patients who do not attain sufficient improvement from conventional hearing aids. The following case report describes sequential bilateral BONEBRIDGE implantation in a 25-year-old patient with achondroplasia and bilateral mixed-hearing loss with a significant sensorineural component in the setting of chronic suppurative otitis media. Although the patient did not meet the approved BONEBRIDGE criteria, implantation was successful with improvements in audiological outcomes and self-reported quality of life. There were no reported complications at 5-years post-implantation.


Subject(s)
Achondroplasia , Cochlear Implantation , Hearing Aids , Hearing Loss, Sensorineural , Hearing Loss , Achondroplasia/complications , Achondroplasia/surgery , Adult , Bone Conduction , Cochlear Implantation/adverse effects , Hearing Loss/surgery , Hearing Loss, Conductive/etiology , Hearing Loss, Conductive/surgery , Hearing Loss, Sensorineural/complications , Hearing Loss, Sensorineural/surgery , Humans , Quality of Life
2.
Int J Audiol ; 59(7): 556-565, 2020 07.
Article in English | MEDLINE | ID: mdl-32069128

ABSTRACT

Objective: To assess the performance of an active transcutaneous implantable-bone conduction device (TI-BCD), and to evaluate the benefit of device digital signal processing (DSP) features in challenging listening environments.Design: Participants were tested at 1- and 3-month post-activation of the TI-BCD. At each session, aided and unaided phoneme perception was assessed using the Ling-6 test. Speech reception thresholds (SRTs) and quality ratings of speech and music samples were collected in noisy and reverberant environments, with and without the DSP features. Self-assessment of the device performance was obtained using the Abbreviated Profile of Hearing Aid Benefit (APHAB) questionnaire.Study sample: Six adults with conductive or mixed hearing loss.Results: Average SRTs were 2.9 and 12.3 dB in low and high reverberation environments, respectively, which improved to -1.7 and 8.7 dB, respectively with the DSP features. In addition, speech quality ratings improved by 23 points with the DSP features when averaged across all environmental conditions. Improvement scores on APHAB scales revealed a statistically significant aided benefit.Conclusions: Noise and reverberation significantly impacted speech recognition performance and perceived sound quality. DSP features (directional microphone processing and adaptive noise reduction) significantly enhanced subjects' performance in these challenging listening environments.


Subject(s)
Bone Conduction , Correction of Hearing Impairment/instrumentation , Hearing Aids , Hearing Loss, Conductive/physiopathology , Hearing Loss, Mixed Conductive-Sensorineural/physiopathology , Adult , Female , Hearing Loss, Conductive/rehabilitation , Hearing Loss, Mixed Conductive-Sensorineural/rehabilitation , Humans , Male , Middle Aged , Noise , Outcome Assessment, Health Care , Prosthesis Design , Signal Processing, Computer-Assisted , Speech Perception , Speech Reception Threshold Test
3.
Otol Neurotol ; 41(5): 605-613, 2020 06.
Article in English | MEDLINE | ID: mdl-32080031

ABSTRACT

OBJECTIVE: To present surgical and audiometric outcomes of patients implanted with an active transcutaneous bone conduction implant following the novel middle fossa surgical approach with self-drilling screws. STUDY DESIGN: Retrospective review. SETTING: Tertiary care center. PATIENTS: Thirty-seven adults with either conductive or mixed hearing loss that met indications for an active transcutaneous bone conduction implant were consecutively implanted from April, 2013 to May, 2018. INTERVENTION: Unilateral middle fossa implantation of an active transcutaneous bone conduction implant. MAIN OUTCOME MEASURES: Patient charts were reviewed for surgical outcomes and complications over the 6-year period. Preoperative air conduction, preoperative bone conduction, and 3-month postoperative aided thresholds were recorded. Speech perception was assessed using CNC words and AzBio sentences. Pure-tone averages (PTAs; measured at 0.5, 1.0, 2.0 and 3.0 kHz), air-bone gap, and functional gain were calculated. RESULTS: Mean air conduction and bone conduction PTAs (±standard deviation) of the implanted ear were 66.8 dB (±14.9 dB) and 21.9 dB (±14.0 dB), respectively. Mean aided PTA was 26.5 dB (± 8.5 dB). The average functional gain was 40.3 dB (±19.0 dB). Favorable speech perception outcomes were observed. No complications or instances of revision surgery were reported, with a mean follow-up time of 32 months (range, 9-71 mo). CONCLUSIONS: This is the first paper to describe outcomes of patients implanted with an active transcutaneous bone conduction implant via the middle fossa with self-drilling screws. Favorable surgical outcomes were observed with a follow-up of up to 6 years.


Subject(s)
Hearing Aids , Speech Perception , Adult , Audiometry , Auditory Threshold , Bone Conduction , Bone Screws , Hearing Loss, Conductive , Humans , Retrospective Studies , Treatment Outcome
4.
Cochlear Implants Int ; 21(5): 295-298, 2020 09.
Article in English | MEDLINE | ID: mdl-31530157

ABSTRACT

Background: Cochlear implantation is a well-established treatment for severe-to-profound sensorineural hearing loss. While bone wax is used commonly during mastoidectomy and other bony surgeries as a hemostatic agent, there have been reports of bone wax triggering foreign body reactions, months to years after surgery. This report describes the first known foreign body reaction to bone wax used in cochlear implantation surgery. Case Presentation: A 6-year-old male presented with an unusual post-auricular inflammation two years after cochlear implantation. Extended treatment with oral and intravenous antibiotics failed to resolve the presumed infection. Upon exploration of the mastoid cavity, fragments of bone wax were discovered within the granulation tissue. Excision of bone wax fragments and local flap reconstruction resulted in complete resolution of the inflammatory process. Conclusions: Bone wax has been implicated in foreign body reactions in many different surgical specialties. This is the first reported case of an adverse reaction to bone wax after cochlear implantation. Clinically, the bone wax reaction was misinterpreted as an implant infection, which resulted in extended antibiotic use and delay of appropriate treatment. As a result, bone wax should be used judiciously during mastoidectomy, and particularly in the area of the electrode and soft tissue closure.


Subject(s)
Cochlear Implantation/adverse effects , Cochlear Implants , Foreign-Body Reaction/etiology , Palmitates/adverse effects , Postoperative Complications/etiology , Waxes/adverse effects , Child , Humans , Male
5.
Laryngoscope ; 130(3): 782-789, 2020 03.
Article in English | MEDLINE | ID: mdl-31112331

ABSTRACT

OBJECTIVES/HYPOTHESIS: The objectives of the study were to present an institutional experience with device failures and cochlear reimplantation rates over a 30-year period and to perform a detailed literature review. STUDY DESIGN: Retrospective institutional experience and literature review. METHODS: A review of cochlear implant failures over a period of 30 years, between January 1988 and March 2017, at a single institution was conducted. Cochlear implant failures were calculated based on manufacturer, type of failure, and overall failure rate. Survival analysis was performed using Kaplan-Meier curves. An electronic search of the PubMed, Web of Science, and EMBASE databases revealed 24 articles on the topic of cochlear device failure. Data on reimplantation and device failure rates were extracted from this literature review and analyzed. RESULTS: A total of 804 cochlear implantations were reviewed from three manufacturers. The institutional reimplantation rate was 2.9% compared to the pooled rate of 6.0% calculated from the literature review. Medical failures accounted for 0.5% of the overall failures, device failures accounted for 1.6%, and inconclusive failures account for 0.7%. Survival analysis revealed a significant difference among manufacturers. An improved device failure rate was noted in the adult population (0.8%) as compared to the pediatric population (2.8%). CONCLUSIONS: This 30-year review represents one of the longest series in the literature examining reimplantation, device failure, and medical failure rates. Cochlear implant survival varied by manufacturer and was significantly better in adult compared to pediatric patients. LEVEL OF EVIDENCE: NA Laryngoscope, 130:782-789, 2020.


Subject(s)
Cochlear Implantation , Cochlear Implants , Prosthesis Failure , Reoperation/statistics & numerical data , Adult , Child , Humans , Retrospective Studies , Time Factors
6.
Am J Audiol ; 28(4): 947-963, 2019 Dec 16.
Article in English | MEDLINE | ID: mdl-31829722

ABSTRACT

Purpose A growing body of evidence indicates that treatment of hearing loss by provision of hearing aids leads to improvements in auditory and visual working memory. The purpose of this study was to assess whether similar working memory benefits are observed following provision of cochlear implants (CIs). Method Fifteen adults with postlingually acquired severe bilateral sensorineural hearing loss completed the prospective longitudinal study. Participants were candidates for bilateral cochlear implantation with some aidable hearing in each ear. Implantation surgeries were carried out sequentially, approximately 1 year apart. Working memory was measured with the visual Reading Span Test (Daneman & Carpenter, 1980) at 5 time points: pre-operatively following a 6-month bilateral hearing aid trial, after 6 and 12 months of bimodal (CI plus contralateral hearing aid) listening experience following the 1st CI surgery and activation, and again after 6 and 12 months of bilateral CI listening experience following the 2nd CI surgery and activation. Results Compared to the preoperative baseline, CI listening experience yielded significant improvements in participants' ability to recall test words in the correct serial order after 12 months in the bimodal condition. Individual performance outcomes were variable, but almost all participants showed increases in task performance over the course of the study. Conclusions These results suggest that, similar to appropriate interventions with hearing aids, treatment of hearing loss with CIs can yield working memory benefits. A likely mechanism is the freeing of cognitive resources previously devoted to effortful listening.


Subject(s)
Cochlear Implants , Memory, Short-Term , Reading , Adult , Aged , Aged, 80 and over , Cochlear Implants/psychology , Cognitive Dysfunction/etiology , Cognitive Dysfunction/prevention & control , Female , Hearing Loss, Sensorineural/psychology , Hearing Loss, Sensorineural/therapy , Humans , Longitudinal Studies , Male , Middle Aged , Neuropsychological Tests , Prospective Studies
7.
Otol Neurotol ; 24(2): 228-33, 2003 Mar.
Article in English | MEDLINE | ID: mdl-12621337

ABSTRACT

OBJECTIVE: Technological advances in cochlear implant systems on which a sequence of speech coding strategies have been implemented seem to have resulted in improved speech perception. However, changing selection criteria for implantation have coincided with evolving technology and may confound post-implantation speech perception performance. This study compares speech coding strategy with speech perception performance in severe and profound postlingually deafened adults using one of three successive generations of Nucleus Cochlear Implant speech processors (i.e., Mini Speech Processor, Spectra 22, and SPrint) implementing three speech coding strategies (i.e., MPEAK, SPEAK, and Advanced Combination Encoders; Cochlear Corporation, Englewood, CO, U.S.A.). STUDY DESIGN: Four cohorts of patients were retrospectively reviewed. SETTING: Multicenter, tertiary referral cochlear implant programs in Ontario, Canada. METHODS: Four cohorts of patients (n = 139) were identified based on preimplant audiological measures, duration of deafness, device type, and speech coding strategy. Word and sentence recognition scores at 12 months after implantation were compared using MPEAK with SPEAK22 implemented on the Nucleus 22 speech processors (Mini Speech Processor and Spectra22, respectively) and SPEAK24 as well as Advanced Combination Encoders implemented on the Nucleus 24 SPrint processor. RESULTS: Open-set speech recognition batteries revealed significant improvements in word and sentence scores as advancing technology implemented new speech coding strategies. Subgroup analysis of profoundly deafened patients supported this. Analysis of covariance confirmed that the measured differences could not be accounted for by changing selection criteria for implantation. CONCLUSION: Improvements in performance can be attributed to evolving speech coding strategies and speech processors rather than to differences in preimplant candidacy.


Subject(s)
Cochlear Implantation/instrumentation , Communication Aids for Disabled , Deafness/surgery , Patient Selection , Speech Perception , Audiometry, Pure-Tone , Cohort Studies , Deafness/diagnosis , Equipment Design , Female , Humans , Male , Middle Aged , Postoperative Period , Preoperative Care , Retrospective Studies , Speech Discrimination Tests
SELECTION OF CITATIONS
SEARCH DETAIL
...