Clin Med Res ; 7(3): 103-5, 2009 Sep.
Article in English | MEDLINE | ID: mdl-19625497

ABSTRACT

A warfarin treated patient unexpectedly presented with an elevated international normalized ratio (INR). Repeat testing in two laboratories gave conflicting results. The chromogenic assay of factor X was used to determine the correct INR result. The patient had laboratory results consistent with a dysfibrinogenemia, which prevented detection of the endpoint with a photo-optical detection system. The chromogenic assay of factor X is recommended for monitoring patients on warfarin when the INR cannot be accurately determined due to interference with the fibrin endpoint in the INR.


Subject(s)
Anticoagulants/therapeutic use , Factor X/metabolism , Fibrin/chemistry , International Normalized Ratio , Warfarin/therapeutic use , Aged , Blood Coagulation/drug effects , Chromogenic Compounds , Female , Fibrinogen/immunology , Heart Failure/complications , Humans , Lung Neoplasms/complications , Lung Neoplasms/surgery , Prothrombin Time , Time Factors