ABSTRACT
The use of 911 keV and 129 keV γ-line intensity ratio has been applied for self-absorption correction of the 63 keV (234)Th ((238)U) and 186 keV((226)Ra and (235)U) lines in typical building materials and soil samples. Proposed procedure allows to determine (238)U from the (234)Th line (63 keV) and (226)Ra after subtraction of (235)U interference in the 186 keV. It is important in the case of low uranium concentration and weak intensity of (235)U 143 keV γ energy line, when activity of this radionuclide can be apprised on the natural constant (238)U/(235)U ratio, only (excluding accidental anthropogenic depleted uranium deposition in the soil samples). Therefore, by this method a direct and fast determination of the (226)Ra and other important radionuclides, without one month waiting period for (226)Ra-(222)Rn daughter equilibrium, is possible. The accuracy of the method has been confirmed (relative relation deviation <10%) for typical buildings materials such as: tales, bricks, concrete blocks and various type of ceramic materials.