Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 6 de 6
Filter
Add more filters










Database
Language
Publication year range
1.
Cryst Growth Des ; 23(7): 5093-5101, 2023 Jul 05.
Article in English | MEDLINE | ID: mdl-37426547

ABSTRACT

Understanding the relation between surface morphology during epitaxy of GaN:Si and its electrical properties is important from both the fundamental and application perspectives. This work evidences the formation of nanostars in highly doped GaN:Si layers with doping level ranging from 5 × 1019 to 1 × 1020 cm-3 grown by plasma-assisted molecular beam epitaxy (PAMBE). Nanostars are 50-nm-wide platelets arranged in six-fold symmetry around the [0001] axis and have different electrical properties from the surrounding layer. Nanostars are formed in highly doped GaN:Si layers due to the enhanced growth rate along the a-direction ⟨112̅0⟩. Then, the hexagonal-shaped growth spirals, typically observed in GaN grown on GaN/sapphire templates, develop distinct arms that extend in the a-direction ⟨112̅0⟩. The nanostar surface morphology is reflected in the inhomogeneity of electrical properties at the nanoscale as evidenced in this work. Complementary techniques such as electrochemical etching (ECE), atomic force microscopy (AFM), and scanning spreading resistance microscopy (SSRM) are used to link the morphology and conductivity variations across the surface. Additionally, transmission electron microscopy (TEM) studies with high spatial resolution composition mapping by energy-dispersive X-ray spectroscopy (EDX) confirmed about 10% lower incorporation of Si in the hillock arms than in the layer. However, the lower Si content in the nanostars cannot solely be responsible for the fact that they are not etched in ECE. The compensation mechanism in the nanostars observed in GaN:Si is discussed to be an additional contribution to the local decrease in conductivity at the nanoscale.

2.
Opt Express ; 30(7): 10709-10722, 2022 Mar 28.
Article in English | MEDLINE | ID: mdl-35473031

ABSTRACT

We demonstrate electrically pumped III-nitride edge-emitting laser diodes (LDs) with nanoporous bottom cladding grown by plasma-assisted molecular beam epitaxy on c-plane (0001) GaN. After the epitaxy of the LD structure, highly doped 350 nm thick GaN:Si cladding layer with Si concentration of 6·1019 cm-3 was electrochemically etched to obtain porosity of 15 ± 3% with pore size of 20 ± 9 nm. The devices with nanoporous bottom cladding are compared to the reference structures. The pulse mode operation was obtained at 448.7 nm with a slope efficiency (SE) of 0.2 W/A while the reference device without etched cladding layer was lasing at 457 nm with SE of 0.56 W/A. The design of the LDs with porous bottom cladding was modelled theoretically. Performed calculations allowed to choose the optimum porosity and thickness of the cladding needed for the desired optical mode confinement and reduced the risk of light leakage to the substrate and to the top-metal contact. This demonstration opens new possibilities for the fabrication of III-nitride LDs.

3.
Materials (Basel) ; 15(1)2021 Dec 29.
Article in English | MEDLINE | ID: mdl-35009382

ABSTRACT

The design of the active region is one of the most crucial problems to address in light emitting devices (LEDs) based on III-nitride, due to the spatial separation of carriers by the built-in polarization. Here, we studied radiative transitions in InGaN-based LEDs with various quantum well (QW) thicknesses-2.6, 6.5, 7.8, 12, and 15 nm. In the case of the thinnest QW, we observed a typical effect of screening of the built-in field manifested with a blue shift of the electroluminescence spectrum at high current densities, whereas the LEDs with 6.5 and 7.8 nm QWs exhibited extremely high blue shift at low current densities accompanied by complex spectrum with multiple optical transitions. On the other hand, LEDs with the thickest QWs showed a stable, single-peak emission throughout the whole current density range. In order to obtain insight into the physical mechanisms behind this complex behavior, we performed self-consistent Schrodinger-Poisson simulations. We show that variation in the emission spectra between the samples is related to changes in the carrier density and differences in the magnitude of screening of the built-in field inside QWs. Moreover, we show that the excited states play a major role in carrier recombination for all QWs, apart from the thinnest one.

4.
BMC Palliat Care ; 19(1): 101, 2020 Jul 09.
Article in English | MEDLINE | ID: mdl-32646517

ABSTRACT

BACKGROUND: The interest in physiotherapy programs for individuals in hospice is increasing. The aim of our study was to assess the impact of a multi-component, individualized physiotherapy program on the functional and emotional conditions and quality of life of patients receiving hospice services in the home. METHODS: The study included 60 patients (mean 66.3 years) receiving hospice services in the home. A model of a physiotherapy program was designed, including breathing, strengthening, transfer, gait, balance, functional, and ergonomic exercises, as well as an adaptation of the patient's living environment to functional needs. The tests were performed before and after the intervention. The study used the Activities of Daily Living (ADL) and Instrumental Activities of Daily Living (IADL) scales, the World Health Organization Quality of Life - Bref (WHOQOL-BREF), the Visual Analogue Scale (VAS) pain scale, the Tinetti POMA Scale, and the Geriatric Depression Scale (GDS). To enable comparison of our results worldwide, a set of International Classification of Functioning, Disability and Health (ICF) categories was used. RESULTS: The average functional level of the ADL (mean 2.9) and the IADL (mean 11.9), as well as the WHOQOL-BREF (mean 46.4) of the patients before the intervention were low, whereas the intensity of pain (VAS mean 5.8), the risk of falling (Tinetti mean 8.2), and depression (GDS mean 16.7) were recorded as high. After the completion of the intervention program, a significant improvement was found in the ADL (mean 4.0), IADL (mean 13.9), WHOQOL-BREF (mean 52.6), VAS (mean 5.1), risk of falling (Tinetti mean 12.3), and GDS (mean 15.7) scores. CONCLUSIONS: The physiotherapeutic intervention had a significant impact on improving the performance of ADL, as well as the emotional state and quality of life of patients receiving hospice services in the home. The results of our research provide evidence of the growing need for physiotherapy in individuals in hospice and for comprehensive assessment by means of ICF. Registered 02.12.2009 in the Research Registry ( https://www.researchregistry.com/why-register ) under the number research registry 5264.


Subject(s)
Home Care Services/standards , Hospices/methods , Physical Therapy Modalities/standards , Activities of Daily Living , Aged , Aged, 80 and over , Female , Home Care Services/trends , Hospices/trends , Humans , Male , Middle Aged , Physical Therapy Modalities/psychology , Psychometrics/instrumentation , Psychometrics/methods , Surveys and Questionnaires
5.
Nanoscale ; 12(10): 6137-6143, 2020 Mar 12.
Article in English | MEDLINE | ID: mdl-32129781

ABSTRACT

Typical methods of doping quantification are based on spectroscopy or conductivity measurements. The spatial dopant distribution assessment with nanometer-scale precision is limited usually to one or two dimensions. Here we demonstrate an approach to detect three-dimensional dopant homogeneity in GaN:Si layers using electrochemical etching (ECE). GaN:Si layers are grown by plasma-assisted molecular beam epitaxy. Dopant incorporation is uniform when the growth front morphology is atomically flat. Non-uniform Si incorporation into GaN is observed when step-bunches are present on the surface during epitaxy. In this study we show that local Si concentration in the area of step-bunch is about three times higher than in the area between step-bunches. ECE spatial resolution in our experiment is estimated to be about 50 nm. This makes ECE a simple and quantitative probing tool for local three-dimensional conductivity homogeneity assessment. Our study proves that ECE could be important both for fundamental studies of crystal growth physics and impurity incorporation and for ion-implanted structures and post-processing device control.

6.
Opt Express ; 24(18): 20119-31, 2016 Sep 05.
Article in English | MEDLINE | ID: mdl-27607620

ABSTRACT

We present the concept, the fabrication processes and the experimental results for materials and optics that can be used for terahertz field-effect transistor detector focal plane arrays. More specifically, we propose 3D printed arrays of a new type - diffractive multi-zone lenses of which the performance is superior to that of previously used mono-zone diffractive or refractive elements and evaluate them with GaN/AlGaN field-effect transistor terahertz detectors. Experiments performed in the 300-GHz atmospheric window show that the lens arrays offer both a good efficiency and good uniformity, and may improve the signal-to-noise ratio of the terahertz field-effect transistor detectors by more than one order of magnitude. In practice, we tested 3 × 12 lens linear arrays with printed circuit board THz detector arrays used in postal security scanners and observed significant signal-to-noise improvements. Our results clearly show that the proposed technology provides a way to produce cost-effective, reproducible, flat optics for large-size field-effect transistor THz-detector focal plane arrays.

SELECTION OF CITATIONS
SEARCH DETAIL
...