Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 4 de 4
Filter
Add more filters










Database
Publication year range
1.
Zhongguo Yi Xue Ke Xue Yuan Xue Bao ; 46(2): 297-300, 2024 Apr.
Article in Chinese | MEDLINE | ID: mdl-38686729

ABSTRACT

Bone infarction has a low incidence in clinical practice and mostly occurs in the metaphysis and diaphysis.Few studies report the advanced imaging technique for bone infarction.Here we reported the fast field echo resembling a CT using restricted echo-spacing and calcium-suppressed spectral CT imaging for a case of multifocal bone infarcts in both lower extremities,aiming to provide diagnostic experience for clinical practice.


Subject(s)
Infarction , Magnetic Resonance Imaging , Tomography, X-Ray Computed , Humans , Male , Calcium , Infarction/diagnostic imaging , Lower Extremity/diagnostic imaging , Lower Extremity/blood supply , Magnetic Resonance Imaging/methods , Tomography, X-Ray Computed/methods , Adult
2.
Zhongguo Yi Xue Ke Xue Yuan Xue Bao ; 43(1): 57-62, 2021 Feb 28.
Article in Chinese | MEDLINE | ID: mdl-33663664

ABSTRACT

Objective To investigate the intra-and inter-observer reproducibility of iodine concentrations of abdominal parenchymal organs based on spectral CT.Methods The water-free iodine images of the venous phase were retrospectively obtained from 50 patients with abdominal dynamic spectral CT scans.The iodine concentrations were measured in the left,right and caudate lobes of liver,spleen,pancreas and bilateral kidneys.Intraclass correlation coefficient(ICC)and Bland-Altman plot were employed to analyze the intra-and inter-observer reproducibility.Results The intra-observer ICCs of the left,right and caudate lobes of liver,spleen,pancreas,and left and right kidneys were 0.938(0.894,0.965),0.932(0.884,0.961),0.939(0.895,0.965),0.947(0.909,0.970),0.912(0.851,0.949),0.946(0.906,0.969)and 0.907(0.842,0.946),which indicated good intra-observer reproducibility.The inter-observer ICCs of the left,right and caudate lobes of liver,spleen,pancreas,and left and right kidneys were 0.947(0.909,0.970),0.927(0.875,0.958),0.943(0.902,0.968),0.956(0.924,0.975),0.934(0.887,0.962),0.927(0.875,0.958)and 0.892(0.818,0.937),which indicated good inter-observer reproducibility.Bland-Altman plots presented that more than 95% points of the intra-observer differences located within 95% CI of limits of agreement for the caudate lobe of liver,spleen,pancreas and bilateral kidneys,which was same as inter-observer differences of the caudate lobe of liver,spleen and right kidney.Conclusion The iodine concentration measurement based on the spectral CT presented good intra-and inter-observer reproducibility for the caudate lobe of liver and spleen.


Subject(s)
Iodine , Humans , Observer Variation , Reproducibility of Results , Retrospective Studies , Tomography, X-Ray Computed
3.
Zhongguo Yi Xue Ke Xue Yuan Xue Bao ; 42(6): 776-780, 2020 Dec 30.
Article in Chinese | MEDLINE | ID: mdl-33423725

ABSTRACT

Objective To identify the optimal mono-energetic enhanced spectral CT for renal cortex in cortical phase based on the iodine concentration. Methods Fifty patients with normal renal function received the abdominal enhanced spectral CT examination.The iodine concentration and CT values of the multiple mono-energetic spectral images were measured on renal cortex in cortical phase,and the correlation between the iodine concentration and the CT values and the coefficient of variation(CV)were analyzed. Results The correlation analysis demonstrated that the correlation coefficient was 0.994,0.994,0.993,0.987,0.976,0.960,and 0.938 between mono-energetic spectral CT images(40-100 keV with interval 10 keV,respectively)and iodine concentration(all P <0.001).The correlation coefficients of 40 keV,50 keV(P=0.007)and 60 keV(P=0.030)were significantly higher compared with that of 70 keV,and the correlation coefficients were not significantly among 40 keV,50 keV and 60 keV(P =0.590).The CV of renal cortex in cortical phase was 0.21,0.20,and 0.19 for 40 keV,50 keV,and 60 keV,respectively. Conclusion 60 keV is the optimal mono-energy for the enhanced spectral CT of the renal cortex in cortical phase.


Subject(s)
Contrast Media , Iodine , Kidney Cortex/diagnostic imaging , Tomography, X-Ray Computed , Humans , Radiographic Image Interpretation, Computer-Assisted
4.
Chin Med Sci J ; 34(1): 18-23, 2019 Mar 30.
Article in English | MEDLINE | ID: mdl-30961776

ABSTRACT

Objective To evaluate the optic nerve impairment using MRI histogram texture analysis in the patients with optic neuritis.Methods The study included 60 patients with optic neuritis and 20 normal controls. The coronal T2 weighted imaging (T2WI) with fat saturation and enhanced T1 weighted imaging (T1WI) were performed to evaluate the optic nerve. MRI histogram texture features of the involved optic nerve were measured on the corresponding coronal T2WI images. The normal optic nerve (NON) was measured in the posterior 1/3 parts of the optic nerve. Kruskal-Wallis one-way ANOVA was used to compare the difference of texture features and receiver operating characteristic (ROC) curve were performed to evaluate the diagnostic value of texture features for the optic nerve impairment among the affected optic nerve with enhancement (ONwEN), affected optic nerve without enhancement (ONwoEN), contralateral normal appearing optic nerve (NAON) and NON.Results The histogram texture Energy and Entropy presented significant differences for ONwEN vs. ONwoEN (both P=0.000), ONwEN vs. NON (both P=0.000) and NAON vs. NON (both P<0.05). ROC analysis demonstrated that the area under the curve (AUC) of histogram texture Energy were 0.758, 0.795 and 0.701 for ONwEN vs. ONwoEN, ONwEN vs. NON and NAON vs. NON, AUC of Entropy were 0.758, 0.795 and 0.707 for ONwEN vs. ONwoEN, ONwEN vs. NON and NAON vs. NON.Conclusions The altered MRI histogram texture Energy and Entropy could be considered as a surrogate for MRI enhancement to evaluate the involved optic nerve and normal-appearing optic nerve in optic neuritis.


Subject(s)
Magnetic Resonance Imaging , Optic Nerve/diagnostic imaging , Optic Neuritis/diagnostic imaging , Adolescent , Adult , Humans , Middle Aged
SELECTION OF CITATIONS
SEARCH DETAIL
...