Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 20 de 37
Filter
1.
Card Electrophysiol Clin ; 16(2): 169-174, 2024 Jun.
Article in English | MEDLINE | ID: mdl-38749637

ABSTRACT

A 34-year-old woman presented with palpitations and paroxysmal atrial fibrillation (AF). Workup revealed anterior mitral valve prolapse with severe mitral regurgitation. She was referred for surgical repair and underwent a mitral valve replacement, tricuspid valve repair, and bi-atrial cryoMAZE procedure with left atrial appendage ligation. Her postoperative course was complicated by inferior wall myocardial infarction. She subsequently presented with palpitations and underwent electrophysiology study and ablation. This case illustrates pitfalls associated with the surgical MAZE procedure and highlights the challenges in postoperative atrial arrhythmias diagnosis and management.


Subject(s)
Atrial Fibrillation , Maze Procedure , Humans , Atrial Fibrillation/surgery , Atrial Fibrillation/diagnosis , Atrial Fibrillation/physiopathology , Female , Adult , Diagnosis, Differential , Postoperative Complications/diagnosis , Catheter Ablation/adverse effects , Electrocardiography , Tachycardia, Supraventricular/diagnosis , Tachycardia, Supraventricular/physiopathology , Tachycardia, Supraventricular/surgery
2.
J Nucl Cardiol ; : 101867, 2024 Apr 30.
Article in English | MEDLINE | ID: mdl-38697386

ABSTRACT

BACKGROUND: The segment of the latest mechanical contraction (LMC) does not always overlap with the site of the latest electrical activation (LEA). By integrating both mechanical and electrical dyssynchrony, this proof-of-concept study aimed to propose a new method for recommending left ventricular (LV) lead placements, with the goal of enhancing response to cardiac resynchronization therapy (CRT). METHODS: The LMC segment was determined by single-photon emission computed tomography myocardial perfusion imaging (SPECT MPI) phase analysis. The LEA site was detected by vectorcardiogram. The recommended segments for LV lead placement were as follows: (1) the LMC viable segments that overlapped with the LEA site; (2) the LMC viable segments adjacent to the LEA site; (3) If no segment met either of the above, the LV lateral wall was recommended. The response was defined as ≥15% reduction in left ventricular end-systolic volume (LVESV) 6-months after CRT. Patients with LV lead located in the recommended site were assigned to the recommended group, and those located in the non-recommended site were assigned to the non-recommended group. RESULTS: The cohort comprised of 76 patients, including 54 (71.1%) in the recommended group and 22 (28.9%) in the non-recommended group. Among the recommended group, 74.1% of the patients responded to CRT, while 36.4% in the non-recommended group were responders (P = .002). Compared to pacing at the non-recommended segments, pacing at the recommended segments showed an independent association with an increased response by univariate and multivariable analysis (odds ratio 5.00, 95% confidence interval 1.73-14.44, P = .003; odds ratio 7.33, 95% confidence interval 1.53-35.14, P = .013). Kaplan-Meier curves showed that pacing at the recommended LV lead position demonstrated a better long-term prognosis. CONCLUSION: Our findings indicate that pacing at the recommended segments, by integrating of mechanical and electrical dyssynchrony, is significantly associated with an improved CRT response and better long-term prognosis.

3.
Heart Rhythm ; 2024 Mar 09.
Article in English | MEDLINE | ID: mdl-38461922

ABSTRACT

BACKGROUND: Left bundle branch pacing (LBBP) and left ventricular septal pacing (LVSP) are referred to as left bundle branch area pacing. OBJECTIVE: This study investigated whether long-term clinical outcomes differ in patients undergoing LBBP, LVSP, and biventricular pacing (BiVP) for cardiac resynchronization therapy (CRT). METHODS: Consecutive patients with reduced left ventricular ejection fraction (LVEF <50%) undergoing CRT were prospectively enrolled if they underwent successful LBBP, LVSP, or BiVP. The primary composite end point was all-cause mortality or heart failure hospitalization. Secondary end points included all-cause mortality, heart failure hospitalization, and echocardiographic measures of reverse remodeling. RESULTS: A total of 259 patients (68 LBBP, 38 LVSP, and 153 BiVP) were observed for a mean duration of 28.8 ± 15.8 months. LBBP was associated with a significantly reduced risk of the primary end point by 78% compared with both BiVP (7.4% vs 41.2%; adjusted hazard ratio [aHR], 0.22 [0.08-0.57]; P = .002) and LVSP (7.4% vs 47.4%; aHR, 0.22 [0.08-0.63]; P = .004]. The adjusted risk of all-cause mortality was significantly higher in LVSP than in BiVP (31.6% vs 7.2%; aHR, 3.19 [1.38-7.39]; P = .007) but comparable between LBBP and BiVP (2.9% vs 7.2%; aHR, 0.33 [0.07-1.52], P = .155). Propensity score adjustment also obtained similar results. LBBP showed a higher rate of echocardiographic response (ΔLVEF ≥10%: 60.0% vs 36.2% vs 16.1%; P < .001) than BiVP or LVSP. CONCLUSION: LBBP yielded long-term clinical outcomes superior to those of BiVP and LVSP. The role of LVSP for CRT needs to be reevaluated because of its high mortality risk.

4.
Circ Arrhythm Electrophysiol ; 17(4): e012717, 2024 Apr.
Article in English | MEDLINE | ID: mdl-38390748

ABSTRACT

BACKGROUND: The effect of contact force (CF) on lesion formation is not clear during pulsed field ablation (PFA). The aim of this study was to evaluate the impact of CF, PFA, and their interplay through the PFA index (PF index) formula on the ventricular lesion size in swine. METHODS: PFA was delivered through the CF-sensing OMNYPULSE catheter. Predefined PFA applications (×3, ×6, ×9, and ×12) were delivered maintaining low (5-25 g), high (26-50 g), and very high (51-80 g) CFs. First, PFA lesions were evaluated on necropsy in 11 swine to investigate the impact of CF/PFA-and their integration in the PF index equation-on lesion size (study characterization). Then, 3 different PF index thresholds-300, 450, and 600-were tested in 6 swine to appraise the PF index accuracy to predict the ventricular lesion depth (study validation). RESULTS: In the study characterization data set, 111 PFA lesions were analyzed. CF was 32±17 g. The average lesion depth and width were 3.5±1.2 and 12.0±3.5 mm, respectively. More than CF and PFA dose alone, it was their combined effect to impact lesion depth through an asymptotically increasing relationship. Likewise, not only was the PF index related to lesion depth in the study validation data set (r2=0.66; P<0.001) but it also provided a prediction accuracy of the observed depth of ±2 mm in 69/73 lesions (95%). CONCLUSIONS: CF and PFA applications play a key role in lesion formation during PFA. Further studies are required to evaluate the best PFA ablation settings to achieve transmural lesions.


Subject(s)
Catheter Ablation , Swine , Animals , Catheter Ablation/adverse effects , Heart Ventricles/surgery , Catheters , Equipment Design
6.
J Arrhythm ; 39(6): 868-875, 2023 Dec.
Article in English | MEDLINE | ID: mdl-38045451

ABSTRACT

Background: Traditional risk scores for recurrent atrial fibrillation (AF) following catheter ablation utilize readily available clinical and echocardiographic variables and yet have limited discriminatory capacity. Use of data from cardiac imaging and deep learning may help improve accuracy and prediction of recurrent AF after ablation. Methods: We evaluated patients with symptomatic, drug-refractory AF undergoing catheter ablation. All patients underwent pre-ablation cardiac computed tomography (cCT). LAVi was computed using a deep-learning algorithm. In a two-step analysis, random survival forest (RSF) was used to generate prognostic models with variables of highest importance, followed by Cox proportional hazard regression analysis of the selected variables. Events of interest included early and late recurrence. Results: Among 653 patients undergoing AF ablation, the most important factors associated with late recurrence by RSF analysis at 24 (+/-18) months follow-up included LAVi and early recurrence. In total, 5 covariates were identified as independent predictors of late recurrence: LAVi (HR per mL/m2 1.01 [1.01-1.02]; p < .001), early recurrence (HR 2.42 [1.90-3.09]; p < .001), statin use (HR 1.38 [1.09-1.75]; p = .007), beta-blocker use (HR 1.29 [1.01-1.65]; p = .043), and adjunctive cavotricuspid isthmus ablation [HR 0.74 (0.57-0.96); p = .02]. Survival analysis demonstrated that patients with both LAVi >66.7 mL/m2 and early recurrence had the highest risk of late recurrence risk compared with those with LAVi <66.7 mL/m2 and no early recurrence (HR 4.52 [3.36-6.08], p < .001). Conclusions: Machine learning-derived, full volumetric LAVi from cCT is the most important pre-procedural risk factor for late AF recurrence following catheter ablation. The combination of increased LAVi and early recurrence confers more than a four-fold increased risk of late recurrence.

7.
Circ Arrhythm Electrophysiol ; 16(12): 663-671, 2023 12.
Article in English | MEDLINE | ID: mdl-37994554

ABSTRACT

BACKGROUND: Pulsed field ablation (PFA) has emerged as an alternative to radiofrequency ablation. However, data on focal point-by-point PFA are scarce. The aim of this study was to compare lesion durability and collateral damage between focally delivered unipolar/biphasic PFA versus radiofrequency in swine. METHODS: Eighteen swine were randomized to low-dose PFA, high-dose PFA, and radiofrequency using a multimodality generator. Radiofrequency delivered by market-available generator served as control group. A contact force-sensing catheter was used to focally deliver PFA/radiofrequency at the pulmonary veins and other predefined sites in the atria. Animals were remapped postprocedurally and 28 days postablation to test lesion durability followed by gross necroscopy and histology. RESULTS: All targeted sites were successfully ablated (contact force value, 13.9±4.1 g). Follow-up remapping showed persistent pulmonary vein isolation in all animals (100%) with lesion durability at nonpulmonary vein sites proven in most (98%). Regardless of the energy source used, the lesion size was similar across the study groups. Transmurality was achieved in 95% of targeted sites and 100% at pulmonary veins. On histology, PFA animals showed more mature scar formation than their radiofrequency counterpart without myocardial necrosis or inflammation. Finally, no sign of collateral damage was observed in any of the groups. CONCLUSIONS: In a randomized preclinical study, focally delivered unipolar/biphasic PFA guided by contact force values was associated with durable lesions on chronic remapping and with mature scar formation on histology without signs of collateral injury on necroscopy. Further studies are needed to investigate the long-term feasibility of this new approach to atrial fibrillation treatment.


Subject(s)
Atrial Fibrillation , Catheter Ablation , Pulmonary Veins , Radiofrequency Ablation , Animals , Catheters , Cicatrix , Swine , Treatment Outcome
8.
J Cardiovasc Electrophysiol ; 34(12): 2621-2625, 2023 Dec.
Article in English | MEDLINE | ID: mdl-37987539

ABSTRACT

INTRODUCTION: Catheter ablation of atrial fibrillation (AF) has emerged as the most effective therapy. However, rare anatomical abnormalities such as situs inversus totalis, dextrocardia, or interrupted inferior vena cava can make ablation challenging. METHODS AND RESULTS: We report a case of a 55-year-old woman with situs inversus totalis, dextrocardia, surgical atrial septal defect repair, left-sided dual chamber pacemaker in place, and symptomatic recurrent persistent AF who underwent successful pulmonary vein and posterior wall isolation by the superior access from the left internal jugular vein. CONCLUSIONS: It is a feasible and safe approach with support of transesophageal echocardiography and multiple emerging technologies.


Subject(s)
Atrial Fibrillation , Catheter Ablation , Dextrocardia , Heart Defects, Congenital , Situs Inversus , Female , Humans , Middle Aged , Atrial Fibrillation/diagnosis , Atrial Fibrillation/diagnostic imaging , Situs Inversus/complications , Situs Inversus/diagnostic imaging , Situs Inversus/surgery , Vena Cava, Inferior/diagnostic imaging , Vena Cava, Inferior/surgery , Dextrocardia/complications , Dextrocardia/diagnostic imaging , Heart Defects, Congenital/surgery
10.
Europace ; 25(9)2023 08 02.
Article in English | MEDLINE | ID: mdl-37477946

ABSTRACT

AIMS: Intracardiac echocardiography (ICE) is a useful but operator-dependent tool for left atrial (LA) anatomical rendering during atrial fibrillation (AF) ablation. The CARTOSOUND FAM Module, a new deep learning (DL) imaging algorithm, has the potential to overcome this limitation. This study aims to evaluate feasibility of the algorithm compared to cardiac computed tomography (CT) in patients undergoing AF ablation. METHODS AND RESULTS: In 28 patients undergoing AF ablation, baseline patient information was recorded, and three-dimensional (3D) shells of LA body and anatomical structures [LA appendage/left superior pulmonary vein/left inferior pulmonary vein/right superior pulmonary vein/right inferior pulmonary vein (RIPV)] were reconstructed using the DL algorithm. The selected ultrasound frames were gated to end-expiration and max LA volume. Ostial diameters of these structures and carina-to-carina distance between left and right pulmonary veins were measured and compared with CT measurements. Anatomical accuracy of the DL algorithm was evaluated by three independent electrophysiologists using a three-anchor scale for LA anatomical structures and a five-anchor scale for LA body. Ablation-related characteristics were summarized. The algorithm generated 3D reconstruction of LA anatomies, and two-dimensional contours overlaid on ultrasound input frames. Average calculation time for LA reconstruction was 65 s. Mean ostial diameters and carina-to-carina distance were all comparable to CT without statistical significance. Ostial diameters and carina-to-carina distance also showed moderate to high correlation (r = 0.52-0.75) except for RIPV (r = 0.20). Qualitative ratings showed good agreement without between-rater differences. Average procedure time was 143.7 ± 43.7 min, with average radiofrequency time 31.6 ± 10.2 min. All patients achieved ablation success, and no immediate complications were observed. CONCLUSION: DL algorithm integration with ICE demonstrated considerable accuracy compared to CT and qualitative physician assessment. The feasibility of ICE with this algorithm can potentially further streamline AF ablation workflow.


Subject(s)
Atrial Fibrillation , Catheter Ablation , Pulmonary Veins , Humans , Atrial Fibrillation/diagnostic imaging , Atrial Fibrillation/surgery , Artificial Intelligence , Feasibility Studies , Echocardiography/methods , Heart Atria/diagnostic imaging , Heart Atria/surgery , Imaging, Three-Dimensional/methods , Pulmonary Veins/diagnostic imaging , Pulmonary Veins/surgery , Algorithms , Catheter Ablation/methods
11.
Heart Rhythm ; 20(10): 1436-1444, 2023 10.
Article in English | MEDLINE | ID: mdl-37495037

ABSTRACT

BACKGROUND: Left bundle branch pacing (LBBP) achieves resynchrony and improves cardiac function in heart failure (HF) patients with reduced ejection fraction (EF) by correcting left bundle branch block (LBBB). Few data on the efficacy of early LBBP in HF with mildly reduced EF (HFmrEF) and LBBB have been reported. OBJECTIVE: The purpose of this study was to explore the efficacy of early LBBP in patients with HFmrEF and LBBB. METHODS: Consecutive patients with HFmrEF (left ventricular EF [LVEF] 35%-50%) and LBBB were prospectively enrolled to receive LBBP (Early-LBBP group) plus guideline-directed medical therapy (GDMT) or GDMT alone (GDMT group). Study outcomes included changes in LVEF, LV end-diastolic diameter (LVEDD), New York Heart Association (NYHA) functional classification, and N-terminal pro-brain natriuretic peptide (NT-proBNP), and clinical events (HF rehospitalization or syncope). Subgroup analysis compared efficacy of LBBP between patients with LBBB only without comorbidities or late gadolinium enhancement (LGE) (LBBB-Only group) and patients with either comorbidities or LGE (LBBB-Combined group). RESULTS: Fifty-four patients were enrolled and analyzed (37 Early-LBBP group; 15 GDMT group). LBBP achieved greater improvement in LVEF (+14.75% ± 7.37% vs -2.42% ± 2.84%; P <.001), reduction of LVEDD (-7.51 ± 5.40 mm vs -0.87 ± 4.36 mm; P <.001) and NYHA classification (-0.84 ± 0.76 vs -0.13 ± 0.74; P = .004), and similar reduction of NT-proBNP (-408.83 ± 920.29 pg/mL vs -229.05 ± 1579.17 pg/mL; P = .610) at 6 months. Early LBBP showed significantly reduced clinical events (0.0% vs 40.0%; P <.001) after 20.68 ± 13.55 months of follow-up. Subgroup analysis showed patients in the LBBB-Only group benefited more from LBBP with regard to LVEF improvement and LVEDD reduction than the LBBB-Combined group. CONCLUSION: Early LBBP with GDMT demonstrated greater improvement of cardiac function and reduced clinical events than GDMT alone in patients with HFmrEF and LBBB.


Subject(s)
Heart Failure , Ventricular Dysfunction, Left , Humans , Bundle-Branch Block/diagnosis , Bundle-Branch Block/therapy , Bundle-Branch Block/etiology , Stroke Volume , Contrast Media , Treatment Outcome , Electrocardiography , Gadolinium , Ventricular Function, Left , Bundle of His , Cardiac Pacing, Artificial/adverse effects
13.
Card Electrophysiol Clin ; 15(1): 31-37, 2023 03.
Article in English | MEDLINE | ID: mdl-36774134

ABSTRACT

Idiopathic ventricular arrhythmias (VA), particularly left ventricular outflow tract (LVOT) VA accounts for up to 10% of all VAs referred for ablative therapy. In addition to being infrequent, its intricate anatomy and its pathophysiology make catheter ablation (CA) of these arrhythmias a challenge even for experts. In this scenario, detailed right ventricular outflow tract as well as LVOT electroanatomic mapping including epicardial mapping are essential. In this article, we will emphasize our approach toward the CA technique used for LVOT VA, particularly IVS and/or LVS VA originating from intramural foci, along with its acute and long-term efficacy and safety.


Subject(s)
Catheter Ablation , Tachycardia, Ventricular , Humans , Tachycardia, Ventricular/surgery , Heart Ventricles/surgery , Arrhythmias, Cardiac , Epicardial Mapping , Catheter Ablation/methods , Electrocardiography , Treatment Outcome
14.
Card Electrophysiol Clin ; 15(1): 75-83, 2023 03.
Article in English | MEDLINE | ID: mdl-36774139

ABSTRACT

Prolonged use of fluoroscopy during catheter ablation (CA) of arrhythmias is associated with a significant exposure to ionizing radiation and risk of orthopedic injuries given the need for heavy protective equipment. CA of ventricular arrhythmias (VAs) arising from the left ventricular (LV) summit is challenging, requiring a vast knowledge of the intricate cardiac anatomy of this area and careful imaging delineation of the different anatomical structures, which is frequently performed using fluoroscopic guidance. Certain techniques, including pericardial mapping and ablation, use of intracoronary wires, and mapping and ablation inside the coronary venous system have been proposed, further prolonging fluoroscopy time. Fluoroless CA procedures are feasible with currently available technology and appear to have similar safety and efficacy outcomes compared with conventional techniques. To successfully perform fluoroless CA of LV summit arrhythmias, it is important to be fully acquainted with intracardiac echocardiography (ICE) imaging and electroanatomic mapping (EAM). We will describe our approach to perform fluoroless CA in LV summit VAs.


Subject(s)
Arrhythmias, Cardiac , Catheter Ablation , Humans , Treatment Outcome , Arrhythmias, Cardiac/diagnostic imaging , Arrhythmias, Cardiac/surgery , Heart Ventricles/diagnostic imaging , Heart Ventricles/surgery , Heart , Catheter Ablation/methods
15.
J Interv Card Electrophysiol ; 66(6): 1383-1389, 2023 Sep.
Article in English | MEDLINE | ID: mdl-36456653

ABSTRACT

INTRODUCTION: Complex atrial tachyarrhythmias (CATs) are commonly observed in patients with prior catheter ablation or cardiac surgery. These arrhythmias are challenging to map and ablate. Historically, entrainment mapping was utilized to characterize CAT. With the advent of high-definition mapping (HDM), full visualization of the CAT circuit is possible which may obviate the need for entrainment mapping. METHODS: We sought to investigate the outcomes of catheter ablation of CAT guided only by HDM. Consecutive patients who underwent CAT ablation from 2017 to 2021 were included in our study (excluding right atrial tachyarrhythmias). Patients were sorted by the type of mapping performed. Group I consisted of patients where HDM alone was utilized with no attempt of entrainment. Group II consisted of patients where both entrainment and HDM were utilized. RESULTS: A total of 67 patients were included in our study, with 40 patients in HDM group (I) and 27 patients in entrainment group (II). No statistically significant difference regarding 1-year freedom from atrial arrhythmias was found between the two groups (80% vs 77.8%, p = 0.819). Four CATs were terminated by entrainment during procedure versus none in the HDM-only group (p = 0.011). CONCLUSIONS: CAT ablation with HDM alone yielded similar 1-year freedom from atrial arrhythmias compared to ablation with HDM and entrainment. Entrainment combined with HDM was associated with higher undesired CAT interruption rate. Further validation is needed with randomized control trials.


Subject(s)
Atrial Fibrillation , Catheter Ablation , Humans , Atrial Fibrillation/surgery , Treatment Outcome , Tachycardia/surgery , Heart Atria/surgery , Catheter Ablation/methods
16.
J Cardiovasc Electrophysiol ; 34(1): 147-152, 2023 01.
Article in English | MEDLINE | ID: mdl-36378783

ABSTRACT

INTRODUCTION: Atrial fibrillation (AF) and premature ventricular complexes (PVC) are common arrhythmias. We aimed to investigate AF prevalence in patients with PVC and its impact on PVC ablation outcomes. METHODS: Consecutive patients undergoing PVC ablation at a single institution between 2016 and 2019 were included and prospectively followed for 2 years. Patients with severe valvular heart disease, hyperthyroidism, malignancy, alcohol use disorder and advanced renal/hepatic diseases were excluded. Twelve-lead electrocardiograms were used to diagnose AF and assess PVC morphology. All PVCs were targeted for ablation using 4-mm irrigated-tip catheters at standardized radiofrequency power guided by 3-D mapping and intracardiac echocardiography. Patients were followed with remote monitoring, device interrogations and office visits every 6 months for 2 years. Detection of any PVCs in follow-up was considered as recurrence. RESULTS: A total of 394 patients underwent PVC ablation and 96 (24%) had concurrent AF. Patients with PVC and AF were significantly older (68.2 ± 10.8 vs. 58.3 ± 15.8 years, p < .001), had lower LV ejection fraction (43.3 ± 13.3% vs. 49.6 ± 12.4%, p < .001), higher CHA2 DS2 -VASc (2.8 ± 1.3 vs. 2.0 ± 1.3, p < .001) than those without. PVCs with ≥2 morphologies were detected in 60.4% and 13.7% patients with vs without AF (p < .001). At 2-year follow-up, PVC recurrence rate was significantly higher in patients with vs without AF (17.7% vs. 9.4%, p = .02). CONCLUSION: AF was documented in 1/4 of patients undergoing PVC ablation and was associated with lower procedural success at long-term follow-up. This was likely attributed to older age, worse LV function and higher prevalence of multiple PVC morphologies in patients with concurrent AF.


Subject(s)
Atrial Fibrillation , Catheter Ablation , Ventricular Premature Complexes , Humans , Atrial Fibrillation/diagnosis , Atrial Fibrillation/epidemiology , Atrial Fibrillation/surgery , Treatment Outcome , Prevalence , Stroke Volume , Ventricular Premature Complexes/diagnosis , Ventricular Premature Complexes/epidemiology , Ventricular Premature Complexes/surgery , Catheter Ablation/adverse effects
17.
J Am Coll Cardiol ; 80(13): 1205-1216, 2022 09 27.
Article in English | MEDLINE | ID: mdl-36137670

ABSTRACT

BACKGROUND: Left bundle branch pacing (LBBP) is the most rapidly growing conduction system pacing technique that is capable of correcting intrinsic left bundle branch block (LBBB). As such, it is potentially an optimal alternative to cardiac resynchronization therapy (CRT) with biventricular pacing (BiVP). OBJECTIVES: The authors sought to compare the efficacy of LBBP-CRT with BiVP-CRT in patients with heart failure and reduced left ventricular ejection fraction (LVEF). METHODS: This is a prospective, randomized trial of patients with nonischemic cardiomyopathy and LBBB with 6-month preplanned follow-up. Crossovers were allowed if LBBP or BiVP were unsuccessful. The primary endpoint was the difference in LVEF improvement between 2 groups. The secondary endpoints included changes in echocardiographic measurements, N-terminal pro-B-type natriuretic peptide (NT-proBNP), New York Heart Association functional class, 6-minute walk distance, QRS duration, and CRT response. RESULTS: The study included 40 consecutive patients (20 males, mean age 63.7 years, LVEF 29.7% ± 5.6%). Crossovers occurred in 10% of LBBP-CRT and 20% of BiVP-CRT. All patients completed follow-up. Intention-to-treat analysis showed significantly higher LVEF improvement at 6 months after LBBP-CRT than BiVP-CRT (mean difference: 5.6%; 95% CI: 0.3-10.9; P = 0.039). LBBP-CRT also appeared to have greater reductions in left ventricular end-systolic volume (-24.97 mL; 95% CI: -49.58 to -0.36 mL) and NT-proBNP (-1,071.80 pg/mL; 95% CI: -2,099.40 to -44.20 pg/mL), and comparable changes in New York Heart Association functional class, 6-minute walk distance, QRS duration, and rates of CRT response compared with BiVP-CRT. CONCLUSIONS: LBBP-CRT demonstrated greater LVEF improvement than BiVP-CRT in heart failure patients with nonischemic cardiomyopathy and LBBB. (Left Bundle Branch Pacing Versus Biventricular Pacing for Cardiac Resynchronization Therapy [LBBP-RESYNC]; NCT04110431).


Subject(s)
Cardiac Resynchronization Therapy , Heart Failure , Arrhythmias, Cardiac/therapy , Bundle-Branch Block/therapy , Cardiac Resynchronization Therapy/methods , Electrocardiography/methods , Heart Failure/therapy , Humans , Male , Middle Aged , Natriuretic Peptide, Brain , Prospective Studies , Stroke Volume , Treatment Outcome , Ventricular Function, Left/physiology
18.
Heart Rhythm ; 19(12): 1984-1992, 2022 12.
Article in English | MEDLINE | ID: mdl-35932987

ABSTRACT

BACKGROUND: Left bundle branch pacing (LBBP) is an emerging physiological pacing modality. How to differentiate LBBP from left ventricular septal pacing (LVSP) remains challenging. OBJECTIVE: We aimed to develop a new personalized intraoperative criterion to confirm left bundle branch (LBB) capture in patients with or without heart failure (HF). METHODS: Patients were enrolled if 12-lead surface electrocardiograms of LBBP, LVSP, temporary His bundle pacing (HBP), and right ventricular septal pacing (RVSP) were recorded during the procedure, with the leads placed in the basal midseptal region. Left ventricular activation time (LVAT) was measured during different pacing modalities. ΔLVAT1 was defined as the difference in LVAT between HBP and LBBP/LVSP. ΔLVAT2 was estimated by the difference in LVAT between RVSP and LBBP/LVSP. ΔLVAT1% and ΔLVAT2% were calculated as the percent reduction of ΔLVAT1 and ΔLVAT2, respectively. RESULTS: A total of 105 consecutive patients were included, of whom 80 (76.2%) had normal cardiac function (65 LBBP and 15 LVSP) and 25 had HF. Patients with LBBP showed significantly shorter LVAT than did those with LVSP. In patients with normal cardiac function, a cutoff value of ΔLVAT1 > 12.5 ms showed 73.9% sensitivity and 93.3% specificity to confirm LBB capture. In patients with HF, a cutoff value of ΔLVAT1% > 9.8% exhibited great accuracy for LBB capture (sensitivity 92.0%; specificity 92.3%). The optimal value of ΔLVAT2% for differentiating LBBP from LVSP was 21.2%. CONCLUSION: Temporary HBP and RVSP can serve as references to confirm LBB capture in an individualized fashion in patients with or without HF.


Subject(s)
Heart Failure , Ventricular Septum , Humans , Bundle of His , Cardiac Pacing, Artificial/methods , Heart Rate , Heart Conduction System , Electrocardiography/methods , Heart Failure/diagnosis , Heart Failure/therapy
20.
Front Cardiovasc Med ; 9: 911234, 2022.
Article in English | MEDLINE | ID: mdl-35837611

ABSTRACT

Aims: To date, the prognostic effects of permanent pacemaker implantation (PPI) after transcatheter aortic valve replacement (TAVR) remain controversial. The purpose of this meta-analysis was to investigate the mid- (1 year) to long-term (> 1 year) clinical and echocardiographic effects of post-procedural PPI in patients after TAVR. Methods: PubMed, Embase, Web of Science, and Cochrane Library databases were systematically searched from the establishment of databases up to 1 December 2021. Studies comparing clinical and echocardiographic outcomes between patients with and without post-TAVR PPI of ≥ 1-year follow-up were collected for further meta-analysis. Results: A total of 39 studies comprising of 83,082 patients were included in this meta-analysis. At mid-term follow-up (1 year), the pooled results demonstrated a higher risk of all-cause mortality in patients with post-procedural PPI than those without following TAVR (relative risk (RR), 1.17; 95% CI, 1.10-1.24; P < 0.00001). No significant differences were observed in cardiovascular mortality (RR, 0.86; 95% CI, 0.71-1.03; P = 0.10) or heart failure rehospitalization (RR, 0.91; 95% CI, 0.58-1.44; P = 0.69) at 1-year follow-up. At long-term follow-up (> 1 year), post-TAVR PPI had negative effects on all-cause mortality (RR, 1.18; 95% CI, 1.09-1.28; P < 0.0001) and heart failure rehospitalization (RR, 1.42; 95% CI, 1.18-1.71; P = 0.0002). There was no difference in long-term cardiovascular mortality between the two groups (RR, 1.15; 95% CI, 0.97-1.36; P = 0.11). Left ventricular ejection fraction (LVEF) was not significantly different at baseline (mean difference, 1.40; 95% CI, -0.13-2.93; P = 0.07), but was significantly lower in the PPI group at 1-year follow-up (mean difference, -3.57; 95% CI, -4.88 to -2.26; P < 0.00001). Conclusion: Our meta-analysis provides evidence that post-TAVR PPI has negative clinical and echocardiographic effects on patients at mid- to long-term follow-up. Further studies are urgently needed to explore the cause of these complications and optimize the treatment and management of patients requiring permanent pacing after TAVR. Systematic Review Registration: [https://www.crd.york.ac.uk/prospero/display_record.php?ID=CRD42021289935], identifier [CRD42021289935].

SELECTION OF CITATIONS
SEARCH DETAIL
...