Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 5 de 5
Filter
Add more filters










Database
Language
Publication year range
1.
Food Chem ; 456: 140063, 2024 Jun 12.
Article in English | MEDLINE | ID: mdl-38878547

ABSTRACT

Precisely detecting trace pesticides and their residues in food products is crucial for ensuring food safety. Herein, a high-performance electrochemical sensing platform was developed for the detection of carbendazim (CBZ) using Co,N co-doped hollow carbon nanocage@carbon nanotubes (Co,N-HC@CNTs) obtained from core-shell ZIF-8@ZIF-67 combined with a poly(3,4-ethylenedioxythiophene) (PEDOT) molecularly imprinted polymer (MIP). The Co,N-HC@CNTs exhibited excellent electrocatalytic performance, benefitting from the synergistic effect of CNTs that provide a large specific surface area and excellent electrical conductivity, Co,N co-doped carbon nanocages that offer high electrocatalytic activity and hollow nanocage structures that ensure rapid diffusion kinetics. The conductive PEDOT-MIP provided specific binding sites for CBZ detection and significantly amplified the detection signal. The sensor showed superior selectivity for CBZ with an extremely low detection limit of 1.67 pmol L-1. Moreover, the method was successfully applied to detect CBZ in tomato, orange and apple samples, achieving satisfactory recovery and accuracy, thus demonstrating its practical feasibility.

2.
Sensors (Basel) ; 24(11)2024 May 25.
Article in English | MEDLINE | ID: mdl-38894202

ABSTRACT

Centrifugal pumps are essential in many industrial processes. An accurate operation diagnosis of centrifugal pumps is crucial to ensure their reliable operation and extend their useful life. In real industry applications, many centrifugal pumps lack flowmeters and accurate pressure sensors, and therefore, it is not possible to determine whether the pump is operating near its best efficiency point (BEP). This paper investigates the detection of off-design operation and cavitation for centrifugal pumps with accelerometers and current sensors. To this end, a centrifugal pump was tested under off-design conditions and various levels of cavitation. A three-axis accelerometer and three Hall-effect current sensors were used to collect vibration and stator current signals simultaneously under each state. Both kinds of signals were evaluated for their effectiveness in operation diagnosis. Signal processing methods, including wavelet threshold function, variational mode decomposition (VMD), Park vector modulus transformation, and a marginal spectrum were introduced for feature extraction. Seven families of machine learning-based classification algorithms were evaluated for their performance when used for off-design and cavitation identification. The obtained results, using both types of signals, prove the effectiveness of both approaches and the advantages of combining them in achieving the most reliable operation diagnosis results for centrifugal pumps.

3.
Anal Chim Acta ; 1290: 342202, 2024 Feb 15.
Article in English | MEDLINE | ID: mdl-38246745

ABSTRACT

BACKGROUND: Lanthanide metal-organic frameworks (Ln-MOFs) are a kind of emerging crystalline porous materials with high fluorescence and easy-to-tunable properties, making them ideal for sensing applications. However, current Ln-MOFs based fluorescent probes are primarily single-emissive or fluorescence-quenched, which greatly limited the detection performances such as sensitivity, accuracy and repeatability, thereby hindering their applications in efficient target monitoring and related disease diagnosis. To address these issues, the reasonable design of Ln-MOFs equipped with dual fluorescence emissions and light-up mode is urgently needed for a high-performance biosensor. RESULTS: A dual-emissive europium doped UiO-66 (Eu@UiO-66-NH2-PMA)-based ratiometric fluorescent biosensing platform was constructed for highly sensitive and selective detection of the histidinemia biomarker-histidine (His). Eu@UiO-66-NH2-PMA (pyromellitic acid abbreviated as PMA) was synthesized utilizing a post-synthetic modification method via coordination interactions between the free -COOH of UiO-66-NH2-PMA and Eu3+, which exhibited characteristic peaks of broad ligand emission and sharp Eu3+ emissions simultaneously. Considering that Cu2+ had the excellent fluorescence quenching ability toward Eu3+ and superior affinity with His, it was deliberately introduced into the Eu@UiO-66-NH2-PMA, acting as active sites for target His responsiveness. The Eu@UiO-66-NH2-PMA/Cu2+/His ternary competition system demonstrated a low detection limit of 74 nM, excellent selectivity and good anti-interference capability that allowed for sensitive analysis of His levels in milk and human serum samples. SIGNIFICANCE: Attributing to the superior luminescent properties, good stability and self-calibration capability of Eu@UiO-66-NH2-PMA, the developed ratiometric light-up sensing platform enabled sensitive, selective and credible analysis of His in complex practical samples, which might provide an available tool for food nutrition guideline and diagnostic applications of His related diseases.


Subject(s)
Amino Acid Metabolism, Inborn Errors , Europium , Histidine Ammonia-Lyase/deficiency , Lanthanoid Series Elements , Metal-Organic Frameworks , Phthalic Acids , Humans , Histidine , Biomarkers , Fluorescent Dyes
4.
Molecules ; 28(21)2023 Oct 30.
Article in English | MEDLINE | ID: mdl-37959766

ABSTRACT

Herein, ZIF-67-derived Co and N-doped carbon (Co/NC) particle-modified multilayer MXene (MXene@Co/NC) was developed as remarkable electrode material for carbendazim (CBZ) detection. MXene as a substrate provides an excellent conductive framework and plentiful accessibility sites. Co/NC particles embedding in MXene can not only prevent the interlayer stacking of MXene but also contribute a great deal of metal catalytic active sites and finally improve the adsorption and catalytic properties of the composite. Accordingly, the MXene@Co/NC electrode displays excellent electrocatalytic activity toward CBZ oxidation. Experimental parameters such as pH value, accumulation time, MXene@Co/NC modification volume and constituent materials' mass ratios were optimized. Under optimal conditions, the as-prepared sensor based on MXene@Co/NC holds a broad linearity range from 0.01 µM to 45.0 µM with a low limit of detection (LOD) of 3.3 nM (S/N = 3, S means the detection signal, while N represents the noise of the instrument). Moreover, the proposed sensor displays excellent anti-interference ability, superior reproducibility, excellent stability, and successfully achieves actual applications for CBZ detection in a lettuce sample.

5.
Molecules ; 27(20)2022 Oct 12.
Article in English | MEDLINE | ID: mdl-36296434

ABSTRACT

A facile and sensitive electrochemical aptamer sensor (aptasensor) based on Au nanoparticles-decorated porous carbon (AuNPs/PC) composite was developed for the efficient determination of the antibiotic drug chloramphenicol (CAP). AuNPs modified metal-organic framework (AuNPs/ZIF-8) is applied as a precursor to synthesize the porous carbon with homogeneous AuNPs distribution through a direct carbonization step under nitrogen atmosphere. The as-synthesized AuNPs/PC exhibits high surface area and improved conductivity. Moreover, the loading AuNPs could enhance the attachment of the aptamers on the surface of electrode through the Au-S bond. When added to CAP, poorly conductive aptamer-CAP complexes are formed on the sensor surface, which increases the hindrance to electron transfer resulting in a decrease in electrochemical signal. Based on this mechanism, the developed CAP aptasensor represents a wide linear detection range of 0.1 pM to 100 nM with a low detection limit of 0.03 pM (S/N = 3). In addition, the proposed aptasensor was employed for the analysis of CAP in honey samples and provided satisfactory recovery.


Subject(s)
Aptamers, Nucleotide , Biosensing Techniques , Graphite , Metal Nanoparticles , Metal-Organic Frameworks , Metal-Organic Frameworks/chemistry , Gold/chemistry , Chloramphenicol , Carbon/chemistry , Aptamers, Nucleotide/chemistry , Electrochemical Techniques/methods , Biosensing Techniques/methods , Porosity , Metal Nanoparticles/chemistry , Limit of Detection , Graphite/chemistry , Nitrogen/chemistry , Anti-Bacterial Agents
SELECTION OF CITATIONS
SEARCH DETAIL
...