Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 6 de 6
Filter
Add more filters










Database
Language
Publication year range
2.
Appl Opt ; 61(2): 523-531, 2022 Jan 10.
Article in English | MEDLINE | ID: mdl-35200892

ABSTRACT

Current source and mask optimization (SMO) research tends to focus on advanced inverse optimization algorithms to accelerate SMO procedures. However, innovations of forward imaging models currently attract little attention, which impacts computational efficiency more significantly. A sampling-based imaging model is established with the innovation of an inverse point spread function to reduce computational dimensions, which can provide an advanced framework for fast inverse lithography. Simulations show that the proposed SMO method with the help of the proposed model can further speed up the algorithm-accelerated SMO procedure by a factor of 3.

3.
Appl Opt ; 60(30): 9404-9410, 2021 Oct 20.
Article in English | MEDLINE | ID: mdl-34807079

ABSTRACT

Extreme ultraviolet (EUV) lithography is a new generation of integrated circuit manufacturing technology with great development prospects. EUV lithography has more significant demand for high exposure latitude (EL) due to greater requirements for the stability of the light source. Source and mask optimization (SMO) technology is widely used to compensate for imaging distortion. In this paper, we propose an EL-aware SMO (ELASMO) method that uses a low-resist threshold sensitivity (LRS) penalty function to improve the EL in EUV lithography. Compared to conventional SMO, the proposed ELASMO method can significantly enhance the aerial image contrast, improve the EL, and enlarge the process window while ensuring high imaging fidelity.

4.
Appl Opt ; 60(31): 9681-9690, 2021 Nov 01.
Article in English | MEDLINE | ID: mdl-34807151

ABSTRACT

Recently, a single vectorial pupil optimization (VPO) was proposed to compensate for the polarization effect induced by thick mask and image optics at one field point in a lithography system, which does not work at full field points. In this paper, we propose a multi-objective VPO (MOVPO) method to obtain a universal vectorial pupil that can compensate for the polarization aberration at full field points. A novel multi-objective cost function, to the best of our knowledge, is built and includes uneven image pattern errors causing by polarization aberration (PA) at full field points in the MOVPO method. Comprehensive simulations demonstrate that the proposed MOVPO method can effectively improve the consistency of imaging and enlarge the overlapped process window at full field points.

5.
Acta Pharmacol Sin ; 39(7): 1208-1216, 2018 Jul.
Article in English | MEDLINE | ID: mdl-29795360

ABSTRACT

Due to the lack of typical clinical symptoms, the average delay time for diagnosis of pulmonary hypertension (PH) is longer than 2 years. It is urgent to find biomarkers for PH diagnosis. In this study we investigated whether plasma microRNAs (miRNAs) can be used as biomarkers for PH diagnosis. We used microarray to identify dynamic miRNAs between PH and non-PH patients. The candidate miRNAs were verified using qRT-PCR in a mouse model of PH, which was induced by monocrotaline (MCT) injection. We observed that miR-21, miR-126, miR-145, miR-191 and miR-150 had no differences between control mice and MCT-treated mice; but plasma miR-451 was significantly decreased in the 2wk-MCT group, with no further decrease in the 4wk-MCT group. Plasma miR-451 was also markedly decreased in PH patients, whereas miR-21, miR-126, miR-150 and miR-320 did not show differences between 53 PH patients and 54 non-PH patients. Receiver operating characteristic curves (ROCs) were constructed from the patient data to assess the clinical diagnostic values of circulating miR-451 and Doppler echocardiography (D-ECHO). The areas under the curve (AUCs) of ROCs for miR-451 and D-ECHO were 0.710 and 0.766, respectively. Combination of miR-451 and D-ECHO with AUC of 0.825 was superior to the use of either miR-451 or D-ECHO alone for PH diagnosis. In conclusion, plasma miR-451 has a moderate diagnostic value in PH comparable to that of D-ECHO, and the combination of miR-451 with D-ECHO has better diagnostic value than either method alone, which may have implications for PH diagnosis.


Subject(s)
Echocardiography , Hypertension, Pulmonary/blood , Hypertension, Pulmonary/diagnosis , MicroRNAs/blood , Animals , Biomarkers/blood , Male , Mice , Mice, Inbred C57BL
6.
Genome Announc ; 6(8)2018 Feb 22.
Article in English | MEDLINE | ID: mdl-29472324

ABSTRACT

Here, we report the complete genome sequence of Xanthomonas arboricola pv. juglandis DW3F3, a strong pathogenic strain isolated from blighted walnut immature fruit (Juglans regia L. cv. Qingxiang). The genome consists of a single chromosome (5,144 kb).

SELECTION OF CITATIONS
SEARCH DETAIL
...