Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 3 de 3
Filter
Add more filters










Database
Language
Publication year range
1.
Eur Heart J Cardiovasc Imaging ; 24(2): 202-211, 2023 Jan 23.
Article in English | MEDLINE | ID: mdl-36214336

ABSTRACT

AIMS: To assess the safety, feasibility, and prognostic value of stress cardiovascular magnetic resonance (CMR) in patients with pacemaker (PM). METHODS AND RESULTS: Between 2008 and 2021, we conducted a bi-centre longitudinal study with all consecutive patients with MR-conditional PM referred for vasodilator stress CMR at 1.5 T in the Institut Cardiovasculaire Paris Sud and Lariboisiere University Hospital. They were followed for the occurrence of major adverse cardiovascular events (MACE) defined as cardiac death or non-fatal myocardial infarction. Cox regression analyses were performed to determine the prognostic value of CMR parameters. The quality of CMR was rated by two observers blinded to clinical details. Of 304 patients who completed the CMR protocol, 273 patients (70% male, mean age 71 ± 9 years) completed the follow-up (median [interquartile range], 7.1 [5.4-7.5] years). Among those, 32 experienced a MACE (11.7%). Stress CMR was well tolerated with no significant change in lead thresholds or pacing parameters. Overall, the image quality was rated good or excellent in 84.9% of segments. Ischaemia and late gadolinium enhancement (LGE) were significantly associated with the occurrence of MACE (hazard ratio, HR: 11.71 [95% CI: 4.60-28.2]; and HR: 5.62 [95% CI: 2.02-16.21], both P < 0.001). After adjustment for traditional risk factors, ischaemia and LGE were independent predictors of MACE (HR: 5.08 [95% CI: 2.58-14.0]; and HR: 2.28 [95% CI: 2.05-3.76]; both P < 0.001). CONCLUSION: Stress CMR is safe, feasible and has a good discriminative prognostic value in consecutive patients with PM.


Subject(s)
Contrast Media , Pacemaker, Artificial , Humans , Male , Middle Aged , Aged , Aged, 80 and over , Female , Prognosis , Longitudinal Studies , Feasibility Studies , Magnetic Resonance Imaging, Cine/methods , Gadolinium , Risk Factors , Magnetic Resonance Spectroscopy , Perfusion , Predictive Value of Tests
3.
J Clin Med ; 9(3)2020 Mar 20.
Article in English | MEDLINE | ID: mdl-32244983

ABSTRACT

Acute myocarditis is associated with cardiac arrhythmia in 25% of cases; a third of these arrhythmias are ventricular tachycardia (VT) or ventricular fibrillation (VF). The implantation of a cardiac defibrillator (ICD) following sustained ventricular arrhythmia remains controversial in these patients. We sought to assess the risk of major arrhythmic ventricular events (MAEs) over time in patients implanted with an ICD following sustained VT/VF in the acute phase of myocarditis compared to those implanted for VT/VF occurring on myocarditis sequelae. Our retrospective observational study included patients implanted with an ICD following VT/VF during acute myocarditis or VT/VF on myocarditis sequelae, from 2007 to 2017, in 15 French university hospitals. Over a median follow-up period of 3 years, MAE occurred in 11 (39%) patients of the acute myocarditis group and 24 (60%) patients of the myocarditis sequelae group. Kaplan-Meier MAE rate estimates at one and three years of follow-up were 19% and 45% in the acute group, and 43% and 64% in the sequelae group. Patients who experienced sustained ventricular arrhythmias during acute myocarditis had a very high risk of VT/VF recurrence during follow-up. These results show that the risk of MAE recurrence remains high after resolution of the acute episode.

SELECTION OF CITATIONS
SEARCH DETAIL
...