Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 6 de 6
Filter
1.
Surg Endosc ; 37(4): 2659-2672, 2023 04.
Article in English | MEDLINE | ID: mdl-36401105

ABSTRACT

BACKGROUND: Many centers worldwide are shifting from laparoscopic to robotic minimally invasive hepato-pancreato-biliary resections (MIS-HPB) but large single center series assessing this process are lacking. We hypothesized that the introduction of robot-assisted surgery was safe and feasible in a high-volume center. METHODS: Single center, post-hoc assessment of prospectively collected data including all consecutive MIS-HPB resections (January 2010-February 2022). As of December 2018, all MIS pancreatoduodenectomy and liver resections were robot-assisted. All surgeons had participated in dedicated training programs for laparoscopic and robotic MIS-HPB. Primary outcomes were in-hospital/30-day mortality and Clavien-Dindo ≥ 3 complications. RESULTS: Among 1875 pancreatic and liver resections, 600 (32%) were MIS-HPB resections. The overall rate of conversion was 4.3%, Clavien-Dindo ≥ 3 complications 25.7%, and in-hospital/30-day mortality 1.8% (n = 11). When comparing the period before and after the introduction of robotic MIS-HPB (Dec 2018), the overall use of MIS-HPB increased from 25.3 to 43.8% (P < 0.001) and blood loss decreased from 250 ml [IQR 100-500] to 150 ml [IQR 50-300] (P < 0.001). The 291 MIS pancreatic resections included 163 MIS pancreatoduodenectomies (52 laparoscopic, 111 robotic) with 4.3% conversion rate. The implementation of robotic pancreatoduodenectomy was associated with reduced operation time (450 vs 361 min; P < 0.001), reduced blood loss (350 vs 200 ml; P < 0.001), and a decreased rate of delayed gastric emptying (28.8% vs 9.9%; P = 0.009). The 309 MIS liver resections included 198 laparoscopic and 111 robotic procedures with a 3.6% conversion rate. The implementation of robotic liver resection was associated with less overall complications (24.7% vs 10.8%; P = 0.003) and shorter hospital stay (4 vs 3 days; P < 0.001). CONCLUSION: The introduction of robotic surgery was associated with greater implementation of MIS-HPB in up to nearly half of all pancreatic and liver resections. Although mortality and major morbidity were not affected, robotic surgery was associated with improvements in some selected outcomes. Ultimately, randomized studies and high-quality registries should determine its added value.


Subject(s)
Laparoscopy , Robotic Surgical Procedures , Humans , Hepatectomy/methods , Liver/surgery , Minimally Invasive Surgical Procedures , Pancreas/surgery , Postoperative Complications/epidemiology , Postoperative Complications/etiology , Postoperative Complications/surgery , Prospective Studies
3.
Scand J Surg ; 109(1): 29-33, 2020 Mar.
Article in English | MEDLINE | ID: mdl-32192422

ABSTRACT

INTRODUCTION: There has been a rapid development in minimally invasive pancreas surgery in recent years. The most recent innovation is robotic pancreatoduodenectomy. Several studies have suggested benefits as compared to the open or laparoscopic approach. This review provides an overview of studies concerning patient selection, volume criteria, and training programs for robotic pancreatoduodenectomy and identified knowledge gaps regarding barriers for safe implementation of robotic pancreatoduodenectomy. MATERIALS AND METHODS: A Pubmed search was conducted concerning patient selection, volume criteria, and training programs in robotic pancreatoduodenectomy. RESULTS: A total of 20 studies were included. No contraindications were found in patient selection for robotic pancreatoduodenectomy. The consensus and the Miami guidelines advice is a minimum annual volume of 20 robotic pancreatoduodenectomy procedures per center, per year. One training program was identified which describes superior outcomes after the training program and shortening of the learning curve in robotic pancreatoduodenectomy. CONCLUSION: Robotic pancreatoduodenectomy is safe and feasable for all indications when performed by specifically trained surgeons working in centers who can maintain a minimum volume of 20 robotic pancreatoduodenectomy procedures per year. Large proficiency-based training program for robotic pancreatoduodenectomy seem essential to facilitate a safe implementation and future research on robotic pancreatoduodenectomy.


Subject(s)
Pancreatic Diseases/surgery , Pancreaticoduodenectomy , Patient Selection , Robotic Surgical Procedures , Clinical Competence/standards , Clinical Competence/statistics & numerical data , Education/standards , Education/statistics & numerical data , Education, Medical, Graduate/standards , Education, Medical, Graduate/statistics & numerical data , Hospitals, High-Volume/standards , Hospitals, High-Volume/statistics & numerical data , Humans , Laparoscopy , Learning Curve , Minimally Invasive Surgical Procedures , Pancreaticoduodenectomy/education , Pancreaticoduodenectomy/methods , Pancreaticoduodenectomy/standards , Pancreaticoduodenectomy/statistics & numerical data , Robotic Surgical Procedures/education , Robotic Surgical Procedures/methods , Robotic Surgical Procedures/standards , Robotic Surgical Procedures/statistics & numerical data , Surgeons/standards , Surgeons/statistics & numerical data , Treatment Outcome
4.
J Vis Exp ; (155)2020 01 03.
Article in English | MEDLINE | ID: mdl-31957744

ABSTRACT

Pancreatic parenchyma sparing surgery for insulinomas avoids the risk of endocrine and exocrine insufficiency, and potential high-risk anastomoses associated with pancreatic resection. Robotic surgery may be used as an alternative for open pancreatic enucleation without compromising dexterity and 3D-vision. We present the case of a 42-year old woman who presented with sweating, tremor and episodes of hypoglycemia. A fasting test confirmed endogenic insulin overproduction. After inconclusive CT- and MRI imaging, endoscopic ultrasonography showed a hypoechoic lesion, which was fully within the pancreatic head. Although consent was obtained for pancreatoduodenectomy, robotic enucleation seemed feasible. After mobilization, intraoperative ultrasonography was used to identify the lesion and its relation with the pancreatic duct. Dissection was performed using a traction suture, hot shears and bipolar diathermia. A sealant patch was applied for hemostasis and a drain placed. The patient developed a grade B pancreatic fistula for which endoscopic sphincterotomy was performed; the surgical drain could be removed in the outpatient clinic after 20 days. Prospective studies should confirm the short- and long-term benefits of robotic enucleation of insulinomas.


Subject(s)
Insulinoma/surgery , Pancreas/surgery , Pancreatic Neoplasms/surgery , Robotic Surgical Procedures , Adult , Dissection , Female , Humans , Insulinoma/diagnostic imaging , Insulinoma/pathology , Pancreatectomy , Pancreatic Ducts/surgery , Pancreatic Neoplasms/pathology , Prospective Studies , Treatment Outcome
5.
J Robot Surg ; 13(6): 717-727, 2019 Dec.
Article in English | MEDLINE | ID: mdl-31049774

ABSTRACT

Minimally invasive surgery (MIS) is quickly becoming mainstream in hepato-pancreato-biliary surgery because of presumed advantages. Surgery for perihilar cholangiocarcinoma (PHC) is highly demanding which may hamper the feasibility and safety of MIS in this setting. This study aimed to systematically review the existing literature on MIS for PHC. A systematic literature review was performed according to the PRISMA statement. The PubMed and EMBASE databases were searched and all studies describing MIS in patients with PHC were included. Data extraction and risk of bias were assessed by two independent researchers. Overall, 21 studies reporting on a total of 142 MIS procedures for PHC were included. These included 82 laparoscopic, 59 robot-assisted and 1 hybrid procedure(s). Risk of bias was deemed substantial. Pooled conversion rate was 7/142 (4.9%), pooled morbidity 30/126 (23.8%), and pooled mortality rate 4/126 (3.2%). The only comparative study, comparing 10 robot-assisted procedures to 32 open procedures, reported a significant increased operative time and higher morbidity rate with MIS. The available evidence on MIS for PHC is limited and generally of poor quality. This systematic review shows that the implementation of MIS for patients with PHC is still in its infancy.


Subject(s)
Klatskin Tumor/surgery , Minimally Invasive Surgical Procedures , Humans
SELECTION OF CITATIONS
SEARCH DETAIL
...