Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 3 de 3
Filter
Add more filters










Database
Language
Publication year range
1.
JACC Case Rep ; 5: 101690, 2023 Jan 04.
Article in English | MEDLINE | ID: mdl-36636511

ABSTRACT

Percutaneous paravalvular leak closure seems a safe alternative to surgery in frail patients. However, it is a challenging procedure that should be tailored to each patient with optimal imaging guidance. Transesophageal echocardiography during the procedure and computed tomography scan/fluoroscopy fusion provide guidance for critical steps, such as PVL localization and crossing. (Level of Difficulty: Advanced.).

2.
Front Cardiovasc Med ; 9: 832242, 2022.
Article in English | MEDLINE | ID: mdl-35295263

ABSTRACT

Backgrounds: Among vascular closure devices (VCDs), the novel collagen plug-based MANTA VCD is the first designed for large bore percutaneous access. We aimed to assess the features and predictors of access-site vascular complications in an unselected trans-femoral transcatheter aortic valve replacement (TF-TAVR) population. Methods: Patients undergoing large bore arteriotomy closure with 18F MANTA VCD following TF-TAVR at a large tertiary care center from September 2019 to January 2021 were prospectively analyzed. Primary Outcome was the MANTA VCD access-site-related complications according to Valve Academic Research Consortium-3 (VARC) definitions. Its incidence and predictors were evaluated. Results: Eighty-eight patients (median age 82 years, 48% male, 3.3 median Society of Thoracic Surgeons score) undergoing TF-TAVR were included, mostly (63%) treated with a self-expandable device and with outer diameter sizes varied from 18F to 24-F. MANTA VCD technical success rate was 98%, while 10 patients (11%) experienced MANTA VCD access-site vascular complications which included 8% of minor complications and only to 2% of major events resulting in VARC type ≥2 bleeding. Vessel occlusion/stenosis (60%), perforation (20%), and pseudoaneurysm/dissection/hematoma (20%) occurred, but all were managed without surgical treatment. Independent predictors of failure were age (p = 0.04), minimum common femoral artery diameter (CFA) (p < 0.01), sheath-to-femoral-artery ratio (SFAR) (p < 0.01), and a lower puncture height (p = 0.03). A CFA diameter <7.1 mm with a SFAR threshold of 1.01 were associated with VCD failure. Conclusions: In a more comers TF-TAVR population, MANTA VCD was associated with reassuring rates of technical success and major access-site vascular complications. Avoiding lower vessel size and less puncture site distance to CFA bifurcation might further improve outcomes.

3.
Article in English | MEDLINE | ID: mdl-34281108

ABSTRACT

Wearable devices (WDs) can objectively assess patient-reported outcomes (PROMs) in clinical trials. In this study, the feasibility and acceptability of using commercial WDs in elderly patients undergoing transcatheter aortic valve replacement (TAVR) or surgical aortic valve replacement (SAVR) will be explored. This is a prospective observational study. Participants were trained to use a WD and a smartphone to collect data on their physical activity, rest heart rate and number of hours of sleep. Validated questionnaires were also used to evaluate these outcomes. A technology acceptance questionnaire was used at the end of the follow up. In our participants an overall good compliance in wearing the device (75.1% vs. 79.8%, SAVR vs. TAVR) was assessed. Half of the patients were willing to continue using the device. Perceived ease of use is one of the domains that scored higher in the technology acceptance questionnaire. In this study we observed that the use of a WD is accepted in our frail population for an extended period. Even though commercial WDs are not tailored for clinical research, they can produce useful information on patient behavior, especially when coordinated with intervention tailored to the single patient.


Subject(s)
Aortic Valve Stenosis , Heart Valve Prosthesis Implantation , Wearable Electronic Devices , Aged , Aortic Valve Stenosis/surgery , Feasibility Studies , Humans , Patient Reported Outcome Measures , Risk Factors , Treatment Outcome
SELECTION OF CITATIONS
SEARCH DETAIL
...