Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 2 de 2
Filter
Add more filters










Database
Language
Publication year range
1.
Odontology ; 110(1): 113-119, 2022 Jan.
Article in English | MEDLINE | ID: mdl-34363147

ABSTRACT

This study aimed to evaluate the effect of three hydrofluoric acid (HF) etching periods on the micro-tensile bond strength between two CAD-CAM ceramic systems [Vita Suprinity (VS) and feldspathic CEREC blocs (CB)] and a composite resin. The ceramics were categorized into six groups based on the surface conditioning protocol used, as follows: G1: CB-HF 5% for 20 s; G2: CB-HF 5% for 40 s; G3: CB-HF 5% for 60 s; G4: VS-HF 5% for 20 s; G5: VS-HF 5% for 40 s; G6: VS-HF 5% for 60 s. Scotchbond Universal was applied onto the pretreated ceramic surfaces and covered with Filtek Z350 XT composite resin. After 24 h, the specimens were cut into microbars (n = 16) and a micro-tensile bond strength test (µTBS) was carried out. An optical microscope was used to examine the fractured microbars. The results showed statistically significant differences between the factors tested (p < 0.01). Moreover, the mean MPa of G1(17.27), G2(13.03), G3(12.82), G4(15.83), G5(21.66), and G6(14.50) was seen to significantly differ. The predominant failure type observed was adhesive, and all three periods of HF etching produced satisfactory bonding between the composite resin and CB. An etching time of 40 s provided the highest µTBS value for VS.


Subject(s)
Dental Bonding , Dental Porcelain , Ceramics , Composite Resins , Computer-Aided Design , Hydrofluoric Acid , Materials Testing , Resin Cements , Surface Properties , Tensile Strength
2.
J Esthet Restor Dent ; 33(3): 516-521, 2021 04.
Article in English | MEDLINE | ID: mdl-32949221

ABSTRACT

OBJECTIVES: To evaluate, in vitro, the fracture load of IPS e.max CAD occlusal veneers at thicknesses of either 0.3 or 0.6 mm luted to enamel or dentin. MATERIALS AND METHODS: Fifty human molars were randomly distributed into five groups (n = 10): G1 - healthy teeth (control); G2-0.3-mm-thick veneers luted to enamel; G3-0.6-mm-thick veneers luted to enamel; G4-0.3-mm-thick veneers luted to dentin; and G5-0.6-mm-thick veneers luted to dentin. After the luting procedures, the specimens were immersed in distilled water at 37°C for 24 hours and then subjected to mechanical loading (106 cycles at 200 N load). The specimens were subjected to a fracture load test in a universal testing machine. Two-way ANOVA and Tukey's test (α = 0.05) were used to analyze data. RESULTS: Only the thickness factor was significant (P = .002). Values of fracture load followed by distinct letters represent significant differences (P < .05): G1 (3204 N ± 730)ab ; G2 (3144 N ± 729)ab ; G3 (2489 N ± 606)b ; G4 (3591 N ± 776)a ; and G5 (2770 N ± 598)ab . CONCLUSION: IPS e.max ultrathin occlusal veneers luted to enamel or dentin obtained fracture load comparable to that of the healthy tooth. CLINICAL SIGNIFICANCE: IPS e.max CAD ultrathin occlusal veneers at 0.3 or 0.6-mm-thick seem to provide good perspectives in relation to the clinical use.


Subject(s)
Dental Porcelain , Dental Veneers , Ceramics , Dental Enamel , Dental Stress Analysis , Dentin , Humans , Materials Testing
SELECTION OF CITATIONS
SEARCH DETAIL
...