Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 5 de 5
Filter
1.
Endocrinol Diabetes Nutr (Engl Ed) ; 71(3): 110-118, 2024 Mar.
Article in English | MEDLINE | ID: mdl-38555107

ABSTRACT

OBJECTIVES: To compare the performance of maternal body fat index (BFI) assessed during the first 20+6 weeks among 138 pregnant women in an ultrasound outpatient clinic as a predictor of gestational diabetes mellitus (GDM) later in pregnancy. METHOD: Maternal visceral and subcutaneous fat was measured with a convex ultrasound probe placed in two locations on the maternal abdominal surface: the first in the mid-sagittal epigastric region, visualising epigastric fat, and the second 2cm above the maternal umbilical scar, visualising periumbilical fat. Ultrasound callipers measured the distance from dermal edge to the linea alba and after from the linea alba to the anterior hepatic surface (epigastric fat). Periumbilical fat was measured from the dermal edge to the linea alba and after from the linea alba to the anterior aortic surface. The BFI formula was [visceral adipose tissue (mm)×subcutaneous adipose tissue (mm)]/maternal height (cm). RESULTS: The best thresholds for predicting GDM outcome for epigastric and periumbilical BFI were 1.2 and 4.8, respectively. Odds ratio, sensitivity and specificity were 5.88 (95% CI 1.86-18.6), 80.9%, 58.0% for the epigastric site and 6.31 (95% CI 1.73-22.94), 84.2%, 54.2% for the periumbilical site. Pre-pregnancy body mass index compatible with adult obesity shows inadequate predictive performance for GDM outcome. Only epigastric BFI above 1.2 maintained statistical significance for GDM in the logistic regression analysis, when compared to periumbilical BFI above 4.8. CONCLUSION: Epigastric BFI above 1.2 during the first half of pregnancy may help identify women at risk of developing GDM later in pregnancy.


Subject(s)
Diabetes, Gestational , Adult , Pregnancy , Female , Humans , Cohort Studies , Adipose Tissue/diagnostic imaging , Obesity , Pregnancy Trimester, First
2.
J Obstet Gynaecol Res ; 47(3): 1023-1030, 2021 Mar.
Article in English | MEDLINE | ID: mdl-33438351

ABSTRACT

AIM: Higher amounts of maternal visceral adipose tissue were related to abnormal outcomes in pregnancy. Our objective was to evaluate the impact of modifiable and nonmodifiable predictors related to abnormal amounts of maternal visceral fat during three trimesters of pregnancy. METHODS: Visceral fat thickness was evaluated by ultrasound during three trimesters centered in the maternal epigastrium (preperitoneal m-VAT) and additionally fat thickness evaluation centered at maternal periumbilical region (periumbilical m-VAT) among cases with gestational age below 20 weeks. The fourth quartile was considered abnormal m-VAT and the first three quartiles as normal m-VAT. Nonmodifiable characteristics included maternal age, past term pregnancies, and ethnicity. Modifiable characteristics included pre-pregnancy body mass index (BMI), weight gain, usual macronutrients, and sugar consumption during pregnancy. RESULTS: Preperitoneal m-VAT was assessed in 270 pregnant women and m-VAT periumbilical assessment in 154. The fourth quartile measurement was 15 mm and 53 mm, respectively. Nonmodifiable predictors including maternal age and past term pregnancies significantly impacted the primary study outcome of abnormal periumbilical m-VAT. Having a non-Caucasian ethnicity had a significant impact on the amount of normal preperitoneal m-VAT. Among the modifiable characteristics, both pre-pregnancy BMI and pre-pregnancy obesity impacted the amount of abnormal preperitoneal and periumbilical m-VAT. CONCLUSION: Abnormal amounts of maternal visceral fat during pregnancy are related to nonmodifiable predictors and those present before pregnancy. No impact was found among weight gain during pregnancy or macronutrients and sugar consumption at pregnancy.


Subject(s)
Intra-Abdominal Fat , Body Mass Index , Demography , Female , Gestational Age , Humans , Infant , Intra-Abdominal Fat/diagnostic imaging , Pregnancy , Pregnancy Trimesters
3.
BMC Pregnancy Childbirth ; 20(1): 576, 2020 Sep 29.
Article in English | MEDLINE | ID: mdl-32993577

ABSTRACT

BACKGROUND: Determining anthropometric measures that indicate different fat deposits can be useful to predict metabolic risk and set specific treatment goals, reducing negative consequences for maternal and fetal health. In cases where pre-gestational weight measure and subsequent body mass index (BMI) values cannot be determined, other anthropometric measurements may be ideal for measuring the nutritional status of pregnant women, especially in low- and middle-income countries. This study aims to identify which anthropometric measurements correlate better with the maternal fat deposits measured by ultrasound. METHODS: A cross-sectional study was conducted with pregnant women from the city of Porto Alegre (city), capital of Rio Grande do Sul (state), southern Brazil, from October 2016 until January 2018. Anthropometrical variables (weight, height, mid-upper arm circumference [MUAC], circumferences of calf and neck and triceps skinfolds [TSF] and subscapular skinfolds [SBSF]), and ultrasound variables (visceral adipose tissue [VAT] and total adipose tissue [TAT]) were collected. To verify the correlation of anthropometric and ultrasound measurements, a non-adjusted and adjusted Spearman correlation was used. The study was approved by the ethics committees. RESULTS: The age median of the 149 pregnant women was 25 years [21-31], pre-pregnancy BMI was 26.22 kg/m² [22.16-31.21] and gestational age was 16.2 weeks [13.05-18.10]. The best measurements correlated with VAT and TAT were MUAC and SBSF, both of which showed a higher correlation than pre-pregnancy BMI. CONCLUSIONS: It is possible to provide a practical and reliable estimate of VAT and TAT from the anthropometric evaluation (MUAC or SBSF) that is low cost, efficient and replicable in an outpatient clinic environment, especially in low- and middle-income countries.


Subject(s)
Body Weights and Measures , Intra-Abdominal Fat/anatomy & histology , Adult , Correlation of Data , Cross-Sectional Studies , Female , Humans , Intra-Abdominal Fat/diagnostic imaging , Organ Size , Pregnancy , Pregnancy Trimester, First , Pregnancy Trimester, Second , Ultrasonography, Prenatal , Young Adult
4.
Diagn Cytopathol ; 43(10): 802-9, 2015 Oct.
Article in English | MEDLINE | ID: mdl-26223029

ABSTRACT

BACKGROUND: The objective of this study was to investigate the performance of the Fournier(®) self-sampled device in the cytological diagnosis of cervical precursor or neoplastic lesions. The colposcopy and cervical biopsy were used as the gold standard evaluation. METHOD: This was a case-control study performed at a cervical pathology outpatient clinic from January 2008 to October 2009. Samples were obtained through physician-collected mode before a colposcopic evaluation. Liquid-based cytology slides obtained with the device in question were stained using the Papanicolaou method and anti-p16 immunocytochemistry and were analyzed by two pathologists blind to the histological and colposcopic diagnoses. RESULTS: Diagnostic performance for Fournier device using Papanicolaou technique was sensitivity 41.1% (Pathologist 1-P1) and 52.9% (Pathologist 2-P2) for diagnosing low-grade intraepithelial lesions; for high-grade lesions and cervical cancer, sensitivity was 68.7% (P1) and 75.0% (P2) and specificity was 81.8% (P1) and 73.8% (P2). When using the anti-p16 immunocytochemistry, the sensitivity for diagnosing low-grade intraepithelial lesions was 57.1% (P1) and 62.9% (P2), and the sensitivity was 87.5% (P1) and 93.8% (P2) for high-grade lesions and cancer. The specificity was 75.0% (P1) and 54.4% (P2). CONCLUSIONS: These results show that when used with "blind" physician-collected cytology in an outpatient setting, the Fournier(®) device achieved a sensitivity and specificity comparable to those obtained by the Pap test traditionally collected during a speculum examination.


Subject(s)
Biopsy/instrumentation , Cervix Uteri/pathology , Colposcopy/instrumentation , Uterine Cervical Dysplasia/diagnosis , Uterine Cervical Neoplasms/diagnosis , Ambulatory Care Facilities , Biopsy/methods , Case-Control Studies , Cervix Uteri/cytology , Colposcopy/methods , Cyclin-Dependent Kinase Inhibitor p16 , Female , Humans , Mass Screening/methods , Neoplasm Proteins/analysis , Papanicolaou Test/methods , Uterine Cervical Neoplasms/pathology , Vaginal Smears/methods , Uterine Cervical Dysplasia/pathology
5.
Acta Cytol ; 56(5): 520-6, 2012.
Article in English | MEDLINE | ID: mdl-23075893

ABSTRACT

INTRODUCTION: Communities of socially excluded immigrant women, especially Muslim, Asian, Aboriginal and Maroon, are among the groups of women with low rates of cervical screening. Exclusion of the pelvic examination could result in a higher acceptance of the cervical screening among these communities and an increase in screening coverage. AIM: To assess the performance of the Fournier(®) cervical specimen self-sampling device for the cytological diagnosis of precursor or neoplastic lesions in the uterine cervix using the Papanicolaou method. METHODS: A case-control study was conducted at the Cervical Pathology Outpatient Clinic. Liquid-based cytology slides were obtained by the Fournier device and stained using the Papanicolaou method. The slides were analyzed by two pathologists, blinded for the colposcopic and histological results and compared to Papanicolaou smears that were obtained using the traditional method of speculum examination. RESULTS: There were 68 patients who were considered free from precursor or neoplastic cervical lesions. There were 35 cases of low-grade lesions, 13 cases of high-grade lesions and 3 cases of squamous-cell carcinoma. According to the first and second pathologists, the sensitivities of the device for identifying precursor or neoplastic cervical lesions were 50.0 and 60.0%, and the specificities of the method were 81.8 and 73.8%. According to the first and second pathologists, the positive predictive values of the diagnostic test were 0.67 and 0.63, and the negative predictive values were 0.68 and 0.71, respectively. CONCLUSION: Sensitivity and specificity of the Fournier device test was comparable to Papanicolaou smears tests obtained using the traditional method with speculum examination.


Subject(s)
Cervix Uteri/pathology , Colposcopy/methods , Papanicolaou Test , Uterine Cervical Dysplasia/diagnosis , Uterine Cervical Neoplasms/diagnosis , Vaginal Smears/methods , Adult , Case-Control Studies , Female , Humans , Middle Aged , Pregnancy , Reproducibility of Results , Sensitivity and Specificity , Vaginal Smears/instrumentation , Young Adult
SELECTION OF CITATIONS
SEARCH DETAIL
...