Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 7 de 7
Filter
2.
J Vasc Surg Venous Lymphat Disord ; 10(1): 146-151, 2022 01.
Article in English | MEDLINE | ID: mdl-34634517

ABSTRACT

OBJECTIVE: The main objectives of the present study were to analyze the right internal jugular vein tunneled dialysis catheter (TDC) tip displacements, functional changes, pathway deformities, and angulations associated with different arm positions. METHODS: We prospectively studied 21 patients who had undergone TDC implantation for hemodialysis via the right internal jugular vein at a single center from February to September 2020. After implantation, a baseline resting fluoroscopy image was taken, and three movement-mimicking images of the ipsilateral arm were obtained for comparison, with the arm in maximum abduction, maximum flexion, and maximum adduction. Device function was analyzed for each movement-mimicking position and correlated with catheter tip displacement, catheter deformity, and catheter pathway angulation. RESULTS: TDC pathway deformity occurred in 16 patients (69.5%). Deformities were more frequent in the movement-mimicking positions than in to the control resting baseline images (P = .004). The different arm positions did not lead to significant tip displacement (either horizontal or vertical; P > .05), nor did they result in significant pathway angulation between the subcutaneous and intravenous regions (P = .114). However, in the maximum abduction position, a positive relationship was present between the catheter pathway angle and impairment of catheter function (P = .028). CONCLUSIONS: Catheter deformity was more frequent and more severe with maximum adduction and flexion of the arm. Although no significant changes were observed in the tip of the catheter with the movements, a positive relationship was found between the catheter pathway angle and impairment of catheter function with the arm in the maximum abduction position.


Subject(s)
Arm/physiology , Catheterization, Central Venous , Jugular Veins , Movement/physiology , Renal Dialysis , Adult , Aged , Female , Humans , Intraoperative Period , Male , Middle Aged , Prospective Studies , Young Adult
3.
Ann Vasc Surg ; 80: 60-69, 2022 Mar.
Article in English | MEDLINE | ID: mdl-34780949

ABSTRACT

BACKGROUND: In the Brazilian public health system, conventional surgery is the standard procedure for treatment of varicose veins (VV). We aimed to compare clinical and quality of life (QoL) results of patients subjected to bilateral treatment of VV by a single-procedure or staged-procedure approach. METHODS: A total of 111 patients undergoing bilateral treatment for VV were treated either by a single-surgery or 2 staged procedures (minimal: 30-day interval) depending on institutional protocol. Patients were evaluated with respect to clinical symptoms and quality of life markers before and after treatment, by use of the VEINES-Sym/QoL and EQ5D-5L scores, and these results were then compared between groups. RESULTS: QoL scores improved in general after treatment. VV specific symptoms and QoL aspects improved equally between the Staged-procedure and Single-surgery groups (VEINES-Sym mean variation 29.7 ± 2.1 vs. 29.9 ± 2.7, respectively; P = 0.340 and VEINES-QoL mean variation 5.5 ± 3.4 vs. 4.5 ± 4.3, respectively; P = 0.369). General QoL, however, showed more improvement in the Staged-procedure than the Single-surgery group (EQD5-5L mean increase 0.1678 ± 0.1555 and 0.0785 ± 0.1384, respectively; P = 0.007). When propensity matched, patient subgroups maintained this same differences in QoL results. CONCLUSIONS: Our findings suggest that the both the Staged- and Single-surgery approach for VV surgical treatment incur similar improvement in disease-specific QoL, and that the Staged-approach may impose less of a burden in the patients' recovery.


Subject(s)
Patient Reported Outcome Measures , Quality of Life , Varicose Veins/surgery , Vascular Surgical Procedures/methods , Brazil , Female , Humans , Male , Middle Aged , Prospective Studies
4.
Ann Vasc Surg ; 61: 165-169, 2019 Nov.
Article in English | MEDLINE | ID: mdl-31336159

ABSTRACT

BACKGROUND: The aim of this study is to analyze whether heparin, used as a lock in fully implantable catheter for chemotherapy (portocath), maintains its activity even if it remains in the catheter for a long period of time. METHODS: According to the institutional protocol, all catheters routinely use the lock solution with 3 mL of heparinized solution after chemotherapy and the time interval between each change as lock in the catheters studied ranged from 7 to 30 days. A total of 25 blood samples from 22 patients with 6 types of neoplasia on chemotherapy or not were collected according to routine, and the 10 mL of liquid contained in the first aspirated reservoir/catheter (corresponding to the lock of the last section), were sent for laboratory analysis for prospectively studied with the following tests: anti-Xa, partially activated thromboplastin time (APTT), thrombin time (TT), reptilase, and thromboelastogram. RESULTS: Heparin activity was found in 96% of the anti-Xa and APTT tests. In relation to TT, 92% presented activity. The reptilase test was performed on 24 samples with significant time reduction in all of them. In the INTEM stage, the thromboelastometry test showed activity in 92% of samples and in the HEPTEM phase there was reduction in time in all samples. In all samples, the heparin activity was found to be independent of the time of use. CONCLUSIONS: We can conclude that lock of heparinized solution used in our service in fully implantable central venous catheters for chemotherapy was maintained with active heparin even after a long period of time (up to 30 days), demonstrating that the half-life of the substance within the catheter is greater than its plasma half-life.


Subject(s)
Anticoagulants/administration & dosage , Antineoplastic Agents/administration & dosage , Catheter Obstruction/etiology , Catheterization, Central Venous/instrumentation , Catheters, Indwelling , Central Venous Catheters , Heparin/administration & dosage , Neoplasms/drug therapy , Adult , Aged , Anticoagulants/adverse effects , Anticoagulants/pharmacokinetics , Blood Coagulation Tests , Catheterization, Central Venous/adverse effects , Drug Monitoring/methods , Female , Half-Life , Heparin/adverse effects , Heparin/pharmacokinetics , Humans , Male , Middle Aged , Risk Factors , Time Factors , Treatment Outcome
5.
Ann Vasc Surg ; 39: 67-73, 2017 Feb.
Article in English | MEDLINE | ID: mdl-27671460

ABSTRACT

BACKGROUND: Iodine contrast medium (ICM) is considered to be gold standard in endovascular procedures, but its nephrotoxicity and hypersensitivity limit the widespread use. Carbon dioxide (CO2) is considered as an alternative for endovascular procedures in patients with contraindication to ICM. However, no studies have compared the outcomes of endovascular aneurysm repair (EVAR) performed with ICM or CO2 among patients with no contraindication to ICM. METHODS: From May 2012 to April 2014, 36 patients with abdominal aortic aneurysms underwent EVAR in a prospective, randomized, and controlled study. Patients were randomized into 2 groups, CO2 or ICM group. RESULTS: We were able to perform the proposed procedures in all patients in this study. There were no conversions to open surgery and no CO2-related complications. Endovascular material costs, duration of surgery, and time of fluoroscopy were similar between groups, and the cost of the contrast media was smaller in the CO2 group than in the ICM group. Among CO2 group procedures, 62.5% of the patients needed ICM complementary use. CONCLUSIONS: The use of CO2 as a contrast medium for EVAR is an alternative in patients with no restriction for ICM, with similar outcomes when compared to ICM, regarding duration of surgery, duration of fluoroscopy, and endovascular material costs. Using CO2, there were no changes in creatinine clearance and no risk of hypersensitivity reactions; moreover, there was a reduction in contrast-related costs for EVAR procedures. However, in our study, additional use of ICM to visualize the internal iliac artery was needed in most procedures.


Subject(s)
Aortic Aneurysm, Abdominal/surgery , Aortography/methods , Blood Vessel Prosthesis Implantation , Carbon Dioxide/administration & dosage , Computed Tomography Angiography , Contrast Media/administration & dosage , Endovascular Procedures , Iohexol/administration & dosage , Radiography, Interventional/methods , Aged , Aged, 80 and over , Aortic Aneurysm, Abdominal/diagnostic imaging , Blood Vessel Prosthesis Implantation/adverse effects , Brazil , Carbon Dioxide/adverse effects , Contrast Media/adverse effects , Endovascular Procedures/adverse effects , Female , Humans , Iohexol/adverse effects , Male , Middle Aged , Operative Time , Predictive Value of Tests , Prospective Studies , Radiography, Interventional/adverse effects , Risk Factors , Time Factors , Treatment Outcome
6.
Ann Vasc Surg ; 28(6): 1473-8, 2014 Aug.
Article in English | MEDLINE | ID: mdl-24704050

ABSTRACT

BACKGROUND: Iodine contrast medium (ICM) is considered gold standard in endovascular revascularization procedures. However, nephrotoxicity and hypersensitivity to ICM are causes that limit its indiscriminate use. Carbon dioxide (CO2) contrast angiography has been used as an alternative in patients with formal contraindication to ICM. However, no studies to the present date have compared in a randomized and prospective way, outcomes of revascularization procedures performed with either ICM or CO2 in patients eligible for use of both contrasts. METHODS: Between April 2012 and April 2013, 35 patients with peripheral arterial disease with arterial lesions classified as Trans-Atlantic Inter-Society Consensus A or B (identified on preoperative angio computed tomography scan) and adequate runoff underwent femoropopliteal revascularization by endovascular technique in a prospective, randomized, and controlled study. Patients were randomized into 2 groups: CO2 group and ICM group, according to the contrast media selected of the procedure. We evaluated the following outcomes in both groups: feasibility of the procedures, complications, surgical outcomes (ankle-brachial index [ABI]), glomerular filtration rate using the Cockcroft-Gault formula, relationship between the volume of injected iodine and postoperative creatinine clearance, quality of the angiographic images obtained with CO2, costs of the endovascular materials, and finally, cost of contrast agents. RESULTS: We were able to perform the proposed procedures in all patients treated in this series (ICM group and CO2). There were no CO2-related complications. No procedures required conversion to open surgery. Clinical results were satisfactory, with regression of ischemia and increased levels of ABI in both groups. Variations in creatinine clearance levels showed a numerical increase in the CO2 group and a decrease in ICM group, however, with no statistically significant difference between the delta clearance in each group. All CO2 arteriograms of the supragenicular arteries were graded as good or fair by both observers with high interobserver image quality concordance. There was no statistical difference between endovascular material costs between the groups, but the contrast cost was significantly lower in CO2 group (P < 0.001). CONCLUSIONS: The use of CO2 in patients with no restriction for ICM is an alternative that does not limit the feasibility of the procedures. Similar outcomes were observed with CO2 when compared with the gold standard contrast (ICM) regarding quality of images produced, with no associated changes in creatinine clearance or hypersensitivity reactions and also allows a reduction in contrast-related costs in angioplasty procedures.


Subject(s)
Carbon Dioxide/economics , Contrast Media/economics , Cost-Benefit Analysis , Endovascular Procedures/economics , Femoral Artery/diagnostic imaging , Health Care Costs , Peripheral Arterial Disease/economics , Peripheral Arterial Disease/therapy , Popliteal Artery/diagnostic imaging , Radiography, Interventional/economics , Adult , Aged , Aged, 80 and over , Ankle Brachial Index , Brazil , Carbon Dioxide/adverse effects , Constriction, Pathologic , Contrast Media/adverse effects , Endovascular Procedures/adverse effects , Feasibility Studies , Female , Femoral Artery/physiopathology , Glomerular Filtration Rate/drug effects , Humans , Male , Middle Aged , Peripheral Arterial Disease/diagnostic imaging , Peripheral Arterial Disease/physiopathology , Popliteal Artery/physiopathology , Predictive Value of Tests , Prospective Studies , Radiography, Interventional/adverse effects , Tomography, X-Ray Computed , Treatment Outcome
7.
J Vasc Surg Venous Lymphat Disord ; 1(4): 370-5, 2013 Oct.
Article in English | MEDLINE | ID: mdl-26992758

ABSTRACT

OBJECTIVE: The aim of our study is to evaluate the incidence of asymptomatic pulmonary embolism (PE) in patients with deep venous thrombosis (DVT), submitted to routine angiography of pulmonary vessels, and analyze the relationship between the site of DVT and extent of PE. METHODS: Between January 2006 and April 2012, 52 consecutive patients with acute inferior limb DVT were divided into two study groups composed of individuals with proximal and distal thrombotic involvement. All patients had no respiratory symptoms and were submitted to routine pulmonary computed tomography angiography for active investigation of PE. We assessed the incidence and extent of PE in both study groups. RESULTS: Thirty-eight patients (72%) had PE, detected by computed tomography angiography. The incidence of PE in patients with proximal and distal thrombosis, respectively, was 72.7% and 73.7%. Occurrence of segmental embolism was equally high in both groups, affecting 71.4% of the patients with distal thrombosis and 66.6% of the individuals with proximal DVT (P > .99). CONCLUSIONS: The incidence of asymptomatic PE observed in patients with DVT is higher than what is reported in the current literature. This supports the importance of screening and the need for high levels of suspicion regarding this complication.

SELECTION OF CITATIONS
SEARCH DETAIL
...