Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 5 de 5
Filter
Add more filters










Database
Language
Publication year range
1.
Clin Oral Investig ; 27(2): 849-858, 2023 Feb.
Article in English | MEDLINE | ID: mdl-35831626

ABSTRACT

OBJECTIVE: This study evaluated the in vitro and in situ effects of phytosphingosine (PHS) associated with tooth brushing on color stability, surface roughness, and microhardness of dental enamel. METHODS: Sixty-four specimens of bovine teeth (6 × 6 × 2 mm) were separated into 8 groups (n = 8): S + TB: PHS (spray) + tooth brushing; TB + S: tooth brushing + PHS (spray); I + TB: PHS (immersion) + tooth brushing; TB + I: tooth brushing + PHS (immersion); TB: tooth brushing; S: PHS spray; I: immersion in PHS solution, and Saliva: immersion in saliva. Tooth brushing simulation (Mavtec, Brazil) was performed (356 rpm on 3.8 cm area by the toothbrush - Soft Tek) for 1, 7, 15, and 30 days. PHS remained in contact with specimens for 15 min. The specimens were evaluated before and after tooth brushing for color alteration (Easy Shade, VITA), and surface roughness (Model SJ-201P Mitutoyo), and Knoop microhardness (HMV-2, Shimadzu Corporation). For the in situ analyses, 8 participants were recruited and received an intraoral device with 6 fragments of bovine enamel (6 × 6 × 2 mm). The properties evaluated were the same as those of the in vitro study. Participants were randomized following best results of in vitro tested protocols, for 15 days: TB, TB + S, I + TB. Data obtained by in vitro (two-way ANOVA, Tukey, p < .05) and in situ (one-way ANOVA, Tukey, p < .05) studies were analyzed. RESULTS: The in vitro study showed that greater color change was found after 30 days. The greatest differences in surface roughness occurred between the initial value and after 1 day. Regarding microhardness, the highest values occurred after 15 and 30 days, which showed similar results. The in situ study showed greater color changes for the TB and I + TB, and greater surface roughness changes for TB as well as a similar increase in microhardness for the PHS protocols, which were higher than TB. CONCLUSIONS: Phytosphingosine leads to an increase in performance regarding color stability, surface roughness, and microhardness when applied. In general, the application of PHS after brushing showed a positive impact on its performance. CLINICAL RELEVANCE: Phytosphingosine proved to be interesting for compound prevention formulations in the dentistry field.


Subject(s)
Tooth Bleaching , Toothbrushing , Animals , Cattle , Color , Dental Enamel , Surface Properties , Tooth , Humans
2.
Int J Prosthodont ; 34(3): 291­299, 2021.
Article in English | MEDLINE | ID: mdl-33616555

ABSTRACT

PURPOSE: To evaluate the effects of 0.2% sodium hypochlorite, Efferdent (Prestige Consumer Healthcare), and 6.25% Ricinus communis on biofilm removal and antimicrobial action on dentures and brushes using nonimmersion or immersion protocols for the brushes. MATERIALS AND METHODS: A total of 45 denture wearers were randomly assigned to a denture immersion protocol for 7 days: 0.85% saline solution for 20 minutes (control); 0.2% sodium hypochlorite for 20 minutes (SH); Efferdent for 3 minutes; or 6.25% Ricinus communis for 20 minutes (RC). The participants were also randomized to immersion (n = 23) or no immersion (n = 22) of their brushes with their dentures in the same solutions. For biofilm evaluation, the dentures were stained and photographed, and the area of the biofilm was measured using Image Tool 3.0 (University of Texas Health Science Center). To evaluate microbial load on dentures and brushes, the biofilm was collected, and the Candida spp and Streptococcus mutans colonies were counted. RESULTS: The SH, Efferdent, and RC groups showed reduced biofilm and Candida spp on dentures regardless of the immersion protocol for the brushes. However, no difference was found in the Candida spp counts collected from the brushes immersed compared to the brushes not immersed in the solutions. The SH and Efferdent groups showed reduced S mutans on both dentures and brushes, except for in the nonimmersion subgroups. CONCLUSION: All solutions reduced denture biofilm and microbial load. However, immersion of brushes in the solutions did not contribute to reducing the microbial load.


Subject(s)
Biofilms , Denture Cleansers , Colony Count, Microbial , Dentures , Humans , Streptococcus mutans
3.
J Esthet Restor Dent ; 33(2): 294-302, 2021 03.
Article in English | MEDLINE | ID: mdl-32445541

ABSTRACT

OBJECTIVE: To evaluate the protective effect of phytosphingosine (PHS) against staining on dental enamel. MATERIALS AND METHODS: Ninety-six specimens of bovine teeth (6 mm × 6 mm × 2 mm) were cut, and initial color (Easyshade, VITA), microhardness (HMV-2, Shimadzu) and fluorescence (Matlabs software, Matworks) measurements were performed. Specimens were separated into four groups according to the treatments: Distilled water (control); Human saliva (HS); PHS; PHS + HS. Specimens (n = 6) were submitted to staining procedures: Distilled water (immersion for 30 days-control); Coffee (15 minutes, twice a day/for 15 days); Black tea (as described for Coffee) and cigarette smoke (20 cigarettes/sample). Final measurements were performed, and data were analyzed (Color-CIEDE2000, fluorescence-2-way ANOVA, Tukey, and microhardness-Kruskal-Wallis Dunn, P < .05). RESULTS: Coffee caused the highest color change (ΔE00 ), followed by black tea, regardless of the treatment employed. Distilled water and cigarette smoke produced similar color changes (P > .05) for the groups control (water = 1.0 + - 0.5/ cigarette = 2.3 0.3) and PHS (water = 0.8 0.4/ cigarette = 2.3 0.4). PHS + HS demonstrated intermediate means than PHS and HS when stained with coffee and tea. After treatments, the least fluorescence alterations occurred for the groups treated with distilled water and cigarette, regardless of the treatment, with no difference (P > .05) between them. There was a significant difference (P < .05) on microhardness between all the groups, as PHS + HS > PHS > HS > Distilled water. CONCLUSIONS: It was concluded that PHS treatment did not protect the staining of the enamel by coffee and tea, but increased the microhardness, both in the presence and absence of a salivary pellicle. PRACTICAL IMPLICATIONS: Phytoshingosine is a novel agent and considered a promising component for anti-biofilm and anti-erosion properties by the formation of a diffusion barrier on the dental enamel. In line, PHS might be considered for anti-staining purposes.


Subject(s)
Dental Enamel , Tooth Bleaching , Animals , Cattle , Color , Humans , Materials Testing , Sphingosine/analogs & derivatives , Staining and Labeling , Surface Properties
4.
J Prosthodont ; 26(6): 516-521, 2017 Aug.
Article in English | MEDLINE | ID: mdl-26833793

ABSTRACT

PURPOSE: To evaluate a solution based on Ricinus communis (Castor oil) for denture cleansing, comparing it to sodium hypochlorite (NaOCl) for the surface roughness of heat-polymerized acrylic resin. MATERIALS AND METHODS: Forty polished and unpolished resin specimens (90 × 30 × 4 mm) were evaluated before and after their exposure to protocol hygiene: brushing the specimens with a specific denture brush and mild soap for 3 minutes, three times a day, and immersing them in hygiene solutions (0.25% NaOCl-S1 and 0.5% NaOCl-S2; 10% R. communis-S3; saline-S4: control) for 20 minutes. Surface roughness was evaluated by rugosimeter and scanning electron microscopy (SEM) before and after the protocol. For evaluation of surface roughness, polished and unpolished surfaces were used. RESULTS: The roughness of the polished surface was not affected by time (p = 0.062), but was affected by solutions (p < 0.0001) and the interaction between factors (p = 0.005). For S1 and S4, the period did not influence the roughness. For S2, there was a change after 7 days, remaining stable after 14 days. For S3, there were changes, and stabilization occurred after 14 days. After 7 and 14 days, S2 and S3 promoted major changes, but after 21 days, there were no differences among solutions, except saline. The unpolished surface was not influenced by factors: period (p = 0.115), solution (p = 0.120), and their interaction (p = 0.382). SEM analysis showed similar results on the evaluation of surface roughness. CONCLUSIONS: The polished surface of the prosthesis was more susceptible to changes when exposed to hygiene solutions, and although the 0.5% NaOCl solution promoted an increase in the surface roughness compared with the same solution at 0.25% and R. communis at 10%, the values are clinically acceptable.


Subject(s)
Acrylic Resins , Castor Oil/pharmacology , Dental Materials , Ricinus , Sodium Hypochlorite/pharmacology , Hygiene , Materials Testing , Microscopy, Electron, Scanning , Surface Properties/drug effects , Toothbrushing
5.
Braz Dent J ; 26(3): 292-6, 2015.
Article in English | MEDLINE | ID: mdl-26200156

ABSTRACT

This study evaluated the abrasiveness of mechanical and combined methods of denture hygiene, by the analysis of mass loss and surface roughness. Acrylic resin specimens (Plexiglass) were brushed by a tooth brushing machine (Mavtec) with a soft brush (Tek) and water (control) or four dentifrices (Sorriso, Colgate, Polident and Corega) (Experimental groups) for 50 min, representing one year of brushing (mechanical method). After brushing, the specimens were immersed in 0.5% sodium hypochlorite simulating a daily cleaning of 20 min for one year (combined method). Distilled water (23 ºC) was employed as control. The mass loss (g) was analyzed by an analytical balance and the surface roughness (µm) by a rugosimeter. Data were subjected to ANOVA and Bonferroni test (α=0.05). Polident dentifrice showed lowest values of mass loss for both methods (mechanical: -0.0072±0.0017, combined:-0.011±0.002) and the combined method resulted in greater mass loss than the mechanical, except for Corega. For the surface roughness, after the mechanical method, the lowest values were registered for water (-0.007±0.016) and Polident (0.402±0.378); for the combined method, water (-0.063±0.013) showed the lowest values; there was no statistically significant difference between methods. It was concluded that Polident was the less abrasive dentifrice and the association between chemical and mechanical methods increased the mass loss but did not change the surface roughness of specimens.


Subject(s)
Denture Cleansers , Dentures , Polymethyl Methacrylate/adverse effects , Surface Properties
SELECTION OF CITATIONS
SEARCH DETAIL
...