ABSTRACT
OBJECTIVES: Driveline infections continue to be a significant complication following left ventricular assist device (LVAD) implantation. Driveline exit-site care is crucial for the prevention of infections; however, there are no uniform guidelines. The goal of this study was to provide an overview of the currently published driveline exit-site care protocols in patients with LVAD. METHODS: A systematic literature review was performed. Studies before 15 December 2020 were included if the number of driveline infections was a primary outcome and the driveline exit-site care protocol was explained. RESULTS: Eleven articles were included in the systematic review, including 1602 patients with LVADs. The median of the frequency of driveline infections in the articles was 13.8% with a range of 0-52.6%. There was a marked variability in the methods of care of driveline exit sites, without a standardized driveline dressing technique in patients with LVADs. The frequency of driveline infections was 6-7.5% in studies using a dressing kit that included chlorhexidine, a silver-based dressing and an anchoring device. Furthermore, there was variability in the anchoring devices and the frequency of dressing changes, which varied from daily to weekly. No specific anchoring device or change frequency was found to be superior. CONCLUSIONS: Based on this systematic review, driveline exit care protocols that included chlorhexidine, a silver-based dressing, the use of an anchoring device and dressing kits might be best in reducing driveline infection rates. However, prospective studies with larger cohorts are needed to establish the optimal protocol for driveline exit-site care.
Subject(s)
Heart Failure , Heart-Assist Devices , Prosthesis-Related Infections , Clinical Protocols , Heart Failure/therapy , Heart Ventricles , Heart-Assist Devices/adverse effects , Humans , Prospective Studies , Prosthesis-Related Infections/epidemiology , Prosthesis-Related Infections/prevention & controlABSTRACT
Pulmonary hypertension (PH) type II (classified by the World Health Organization) is a common complication in chronic left-sided heart failure. In advanced heart failure therapy, fixed PH is an absolute contraindication for heart transplantation after which a left ventricular assist device (LVAD) is the only remaining option. With remote monitoring, we can now continuously evaluate the pulmonary artery pressures during long-term LV unloading by the LVAD. In this case, we demonstrate that fixed PH can be reversed with LVAD implantation, whereby previous thoughts of this concept should be redefined in the era of assist devices.
Subject(s)
Heart Transplantation , Heart-Assist Devices , Hypertension, Pulmonary , Humans , Hypertension, Pulmonary/diagnosis , Hypertension, Pulmonary/etiology , Hypertension, Pulmonary/therapy , Retrospective Studies , Treatment OutcomeABSTRACT
We describe the first patient with a left ventricular assist device (LVAD) driveline infection caused by Mycobacterium chelonae presenting with persistent infection despite conventional antibiotics. Treatment was successful with surgical debridement, driveline exit relocation, and a 4-month period of antibiotics. In the case of a culture-negative LVAD driveline infection, non-tuberculous mycobacteria should be considered. This case illustrates that multidisciplinary collaboration is essential in providing optimal care for LVAD patients.