Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 20 de 33
Filter
1.
Hernia ; 25(3): 781-787, 2021 06.
Article in English | MEDLINE | ID: mdl-32965616

ABSTRACT

PURPOSE: The purpose of this paper was to introduce a new registry in a developing country by describing the demographics, management and 30-day outcomes of patients undergoing ventral hernia repair in the public and private healthcare sectors of South Africa. METHODS: This study was a retrospective review of a prospectively maintained hernia registry from the 1st of February 2019 to 29th of February 2020. RESULTS: 353 ventral hernia repair cases were recorded of which 47% were incisional hernias and the remainder were primary hernias. The median age was 54 years with even distribution of males and females. Half of the patients were obese with a median BMI of 31 kg/m2. The private sector performed 190 cases (54%) and the public sector 163 cases (46%). The public sector had more current smokers undergoing elective repairs, 28% vs 15%, p = 0.01 and performed more emergency repair cases, 21% vs 8%, p < 0.01. The majority (89%) of hernias were repaired with mesh and one-third were repaired laparoscopically. 30 day follow up was obtained in 30% of cases, the private sector had better follow up rates (42% vs 14%). CONCLUSION: Participation in the HIG (SA) registry was low with poor follow up over the first year. Ongoing prospective data capture on the HIG (SA) hernia registry will continue to provide further insights into hernia repair practices in South Africa.


Subject(s)
Hernia, Ventral , Laparoscopy , Female , Health Care Sector , Hernia, Ventral/epidemiology , Hernia, Ventral/surgery , Herniorrhaphy , Humans , Male , Middle Aged , Postoperative Complications , Prospective Studies , Recurrence , Registries , Retrospective Studies , South Africa/epidemiology , Surgical Mesh
2.
Article in English | MEDLINE | ID: mdl-28846867

ABSTRACT

Vitamin B1 and B6 have recently been included in the Dutch clinical guidelines for the general practitioner in the differential diagnosis of dementia. To keep up with the sharp rise in the number of requests, an LC-MS/MS method using stable isotopes as internal standards was developed. The active vitamers thiamine pyrophosphate (TPP) and pyridoxal-5'-phosphate (PLP) in whole blood are simultaneously measured with a short run time of 2min. Whole blood is mixed with internal standard solution containing both TPP-d3 and PLP-d3, followed by deproteinization with a trichloroacetic acid (TCA) solution. A UPLC-MS/MS system from Waters™ was used for chromatographic separation and subsequent detection by electrospray ionization in the positive mode with mass transitions of 425.1>121.85 for TPP and 247.9>149.9 for PLP. The method is linear across the range of 12-4870 nmol/L for TPP and 6-4850 nmol/L for PLP. The mean intra-assay and inter-assay precision are 3.5% and 7.6% respectively for TPP and 3.4% and 6.1% for PLP. The relative matrix effect (TPP 97%, PLP 93%), recovery (TPP 99%, PLP 94%) and lower limit of quantification (TPP 12 nmol/L, PLP 6 nmol/L) meet the applied acceptance criteria. The comparison of the new LC-ESI-MS/MS method for TPP with our current HPLC-Fluorescence method for total thiamine yields the following equation: TPP LC-MS/MS=0.97×total thiamine HPLC - 10.61 (r2=0.94). The comparison of the new LC-ESI-MS/MS method for PLP with our current LC-ESI-MS/MS method results in PLP LC-MS/MS new=1.01×PLP LC-MS/MS old - 1.58 (r2=0.99). In conclusion, this LC-MS/MS based assay is characterized by simple sample processing with a short run time and comparison with the current methods is excellent. The new LC-MS/MS method is a convenient method to determine TPP and PLP in whole blood for both clinical routine and research applications.


Subject(s)
Chromatography, Liquid/methods , Tandem Mass Spectrometry/methods , Thiamine/blood , Vitamin B 6/blood , Humans , Linear Models , Reproducibility of Results , Sensitivity and Specificity , Spectrometry, Mass, Electrospray Ionization/methods
3.
J Infect Dis ; 198(8): 1189-97, 2008 Oct 15.
Article in English | MEDLINE | ID: mdl-18752445

ABSTRACT

BACKGROUND: Ixodes ticks are the main vectors for Borrelia burgdorferi sensu lato. In the United States, B. burgdorferi is the sole causative agent of Lyme borreliosis and is transmitted by Ixodes scapularis. In Europe, 3 Borrelia species-B. burgdorferi, B. garinii, and B. afzelii-are prevalent, which are transmitted by Ixodes ricinus. The I. scapularis salivary protein Salp15 has been shown to bind to B. burgdorferi outer surface protein (Osp) C, protecting the spirochete from antibody-mediated killing. METHODS AND RESULTS: We recently identified a Salp15 homologue in I. ricinus, Salp15 Iric-1. Here, we have demonstrated, by solid-phase overlays, enzyme-linked immunosorbent assay, and surface plasmon resonance, that Salp15 Iric-1 binds to B. burgdorferi OspC. Importantly, this binding protected the spirochete from antibody-mediated killing in vitro and in vivo; immune mice rechallenged with B. burgdorferi preincubated with Salp15 Iric-1 displayed significantly higher Borrelia numbers and more severe carditis, compared with control mice. Furthermore, Salp15 Iric-1 was capable of binding to OspC from B. garinii and B. afzelii, but these Borrelia species were not protected from antibody-mediated killing. CONCLUSIONS: Salp15 Iric-1 interacts with all European Borrelia species but differentially protects B. burgdorferi from antibody-mediated killing, putatively giving this Borrelia species a survival advantage in nature.


Subject(s)
Antigens, Bacterial/metabolism , Bacterial Outer Membrane Proteins/metabolism , Borrelia burgdorferi/drug effects , Borrelia burgdorferi/metabolism , Ixodes/microbiology , Saliva/metabolism , Salivary Proteins and Peptides/pharmacology , Animals , Antibodies, Bacterial/blood , Antibodies, Bacterial/immunology , Borrelia burgdorferi/immunology , Borrelia burgdorferi/pathogenicity , Enzyme-Linked Immunosorbent Assay , Female , Mice , Mice, Inbred C3H , Rabbits , Salivary Proteins and Peptides/metabolism , Surface Plasmon Resonance
4.
Comput Methods Programs Biomed ; 73(3): 221-31, 2004 Mar.
Article in English | MEDLINE | ID: mdl-14980404

ABSTRACT

Recently we have developed a Java-based heterogeneous distributed computing system for the field of magnetic resonance imaging (MRI). It is a software system for embedding the various image reconstruction algorithms that we have created for handling MRI data sets with sparse sampling distributions. Since these data sets may result from multi-dimensional MRI measurements our system has to control the storage and manipulation of large amounts of data. In this paper we describe how we have employed the extensible markup language (XML) to realize this data handling in a highly structured way. To that end we have used Java packages, recently released by Sun Microsystems, to process XML documents and to compile pieces of XML code into Java classes. We have effectuated a flexible storage and manipulation approach for all kinds of data within the MRI system, such as data describing and containing multi-dimensional MRI measurements, data configuring image reconstruction methods and data representing and visualizing the various services of the system. We have found that the object-oriented approach, possible with the Java programming environment, combined with the XML technology is a convenient way of describing and handling various data streams in heterogeneous distributed computing systems.


Subject(s)
Magnetic Resonance Imaging/methods , Programming Languages , Software , Systems Integration , User-Computer Interface
5.
MAGMA ; 15(1-3): 18-26, 2002 Nov.
Article in English | MEDLINE | ID: mdl-12413561

ABSTRACT

We have worked on multi-dimensional magnetic resonance imaging (MRI) data acquisition and related image reconstruction methods that aim at reducing the MRI scan time. To achieve this scan-time reduction we have combined the approach of 'increasing the speed' of k-space acquisition with that of 'deliberately omitting' acquisition of k-space trajectories (sparse sampling). Today we have a whole range of (sparse) sampling distributions and related reconstruction methods. In the context of a European Union Training and Mobility of Researchers project we have decided to integrate all methods into one coordinating software system. This system meets the requirements that it is highly structured in an object-oriented manner using the Unified Modeling Language and the Java programming environment, that it uses the client-server approach, that it allows multi-client communication sessions with facilities for sharing data and that it is a true distributed computing system with guaranteed reliability using core activities of the Java Jini package.


Subject(s)
Algorithms , Brain/anatomy & histology , Image Enhancement/methods , Information Storage and Retrieval/methods , Magnetic Resonance Imaging/methods , Software , Bayes Theorem , Computer Graphics , Humans , Hypermedia , Imaging, Three-Dimensional/methods , Internet , Magnetic Resonance Imaging, Cine/methods , Sample Size , Software Design , Systems Integration , User-Computer Interface
6.
MAGMA ; 12(2-3): 141-52, 2001 May.
Article in English | MEDLINE | ID: mdl-11390270

ABSTRACT

This article describes the Java-based version of the magnetic resonance user interface (MRUI) quantitation package. This package allows MR spectroscopists to easily perform time-domain analysis of in vivo MR spectroscopy data. We show that the Java programming language is very well suited for developing highly interactive graphical software applications such as the MRUI software. We have also established that MR quantitation algorithms, programmed in other languages, can easily be embedded into the Java-based MRUI by using the Java native interface (JNI). This new graphical user interface (GUI) has been conceived for the processing of large data sets and uses prior knowledge data-bases to make interactive quantitation algorithms more userfriendly.


Subject(s)
Brain/metabolism , Magnetic Resonance Spectroscopy/methods , Software , User-Computer Interface , Algorithms , Brain/anatomy & histology , Humans , Magnetic Resonance Spectroscopy/instrumentation , Microcomputers , Phosphorus
7.
Comput Biol Med ; 31(4): 269-86, 2001 Jul.
Article in English | MEDLINE | ID: mdl-11334636

ABSTRACT

This article describes a Java-based graphical user interface for the magnetic resonance user interface (MRUI) quantitation package. This package allows MR spectroscopists to easily perform time-domain analysis of in vivo/medical MR spectroscopy data. We have found that the Java programming language is very well suited for developing highly interactive graphical software applications such as the MRUI system. We also have established that MR quantitation algorithms, programmed in the past in other languages, can easily be embedded into the Java-based MRUI by using the Java native interface (JNI).


Subject(s)
Magnetic Resonance Spectroscopy , Programming Languages , Signal Processing, Computer-Assisted , Software Validation , User-Computer Interface , Algorithms , Humans
9.
Magn Reson Imaging ; 16(9): 1127-37, 1998 Nov.
Article in English | MEDLINE | ID: mdl-9839996

ABSTRACT

The goal of this study was to establish the best approach for quantifying nuclear magnetic resonance (NMR) lines, that in the frequency domain are overlapping with broad, unwanted background features. To perform the quantitative data analysis in a controlled way, test signals were designed and utilised, derived from two different real-world in vivo nuclear magnetic resonance signals. One of the main conclusions of the study was that the quantification methods currently available to the biomedical research groups can deliver the correct values of the quantitative parameters, but that great care should be taken in using optimal input parameters for the computer programs concerned.


Subject(s)
Magnetic Resonance Spectroscopy/methods , Bayes Theorem , Data Interpretation, Statistical , Europe , Humans , Likelihood Functions , Time Factors
10.
J Magn Reson ; 132(2): 197-203, 1998 Jun.
Article in English | MEDLINE | ID: mdl-9632545

ABSTRACT

Quantification of metabolites in 1H spectra is difficult because of the presence of an unwanted water signal. Preprocessing, or removing the water contribution of a 1H spectrum, in the time domain is usually done using the state-space approach HSVD. HSVD removes the residual water and its side lobes, thereby reducing the baseline for the metabolites of interest and allowing subsequent data analysis using more sophisticated nonlinear least squares algorithms. However, the HSVD algorithm is computationally expensive because it estimates the signal subspace using the singular value decomposition (SVD). We show here that replacing the SVD by a low-rank revealing decomposition speeds up the computations without affecting the accuracy of the wanted parameter estimates. Copyright 1998 Academic Press.

11.
J Virol ; 72(1): 497-503, 1998 Jan.
Article in English | MEDLINE | ID: mdl-9420251

ABSTRACT

Coronaviruses are assembled by budding into a pre-Golgi compartment from which they are transported along the secretory pathway to leave the cell. In cultured epithelial cells, they are released in a polarized fashion; depending on the virus and cell type, they are sorted preferentially either to the apical domain or to the basolateral plasma membrane domain. In this study, we investigated the role of the coronavirus spike protein, because of its prominent position in the virion the prime sorting candidate, in the directionality of virus release. Three independent approaches were taken. (i) The inhibition of N glycosylation by tunicamycin resulted in the synthesis of spikeless virions. The absence of spikes, however, did not influence the polarity in the release of virions. Thus, murine hepatitis virus strain A59 (MHV-A59) was still secreted from the basolateral membranes of mTAL and LMR cells and from the apical sides of MDCK(MHVR) cells, whereas transmissible gastroenteritis virus (TGEV) was still released from the apical surfaces of LMR cells. (ii) Spikeless virions were also studied by using the MHV-A59 temperature-sensitive mutant Albany 18. When these virions were produced in infected LMR and MDCK(MHVR) cells at the nonpermissive temperature, they were again preferentially released from basolateral and apical membranes, respectively. (iii) We recently demonstrated that coronavirus-like particles resembling normal virions were assembled and released when the envelope proteins M and E were coexpressed in cells (H. Vennema, G.-J. Godeke, J. W. A. Rossen, W. F. Voorhout, M. C. Horzinek, D.-J. E. Opstelten, and P. J. M. Rottier, EMBO J. 15:2020-2028, 1996). The spikeless particles produced in mTAL cells by using recombinant Semliki Forest viruses to express these two genes of MHV-A59 were specifically released from basolateral membranes, i.e., with the same polarity as that of wild-type MHV-A59. Our results thus consistently demonstrate that the spike protein is not involved in the directional sorting of coronaviruses in epithelial cells. In addition, our observations with tunicamycin show that contrary to the results with some secretory proteins, the N-linked oligosaccharides present on the viral M proteins of coronaviruses such as TGEV also play no role in viral sorting. The implications of these conclusions are discussed.


Subject(s)
Coronavirus/physiology , Coronavirus/pathogenicity , Membrane Glycoproteins/physiology , Viral Envelope Proteins/physiology , Animals , Base Sequence , Cell Line , Cell Polarity , Coronavirus/genetics , DNA Primers/genetics , Dogs , Epithelial Cells/virology , LLC-PK1 Cells , Membrane Glycoproteins/genetics , Mice , Murine hepatitis virus/genetics , Murine hepatitis virus/pathogenicity , Murine hepatitis virus/physiology , Mutation , Spike Glycoprotein, Coronavirus , Swine , Temperature , Transmissible gastroenteritis virus/genetics , Transmissible gastroenteritis virus/pathogenicity , Transmissible gastroenteritis virus/physiology , Tunicamycin/pharmacology , Viral Envelope Proteins/genetics , Viral Proteins/genetics , Viral Proteins/physiology , Virus Replication
13.
S Afr Med J ; 85(10 Suppl): 1091-6, 1995 Oct.
Article in English | MEDLINE | ID: mdl-8914559

ABSTRACT

OBJECTIVE: To determine the outcome of babies of mothers with severe rhesus (Rh) incompatibility treated by elective delivery when the amniotic optical density at 450 nm crossed Whitfield's action line (group 1), by plasmapheresis and immunotherapy (group 2) or by means of intra-uterine intravascular transfusions (group 3). STUDY DESIGN: A retrospective study of 55 mothers and their 57 fetuses with severe Rh incompatibility at < 34 weeks' pregnancy duration. MAIN OUTCOME PARAMETERS: Number of mothers in each treatment group, prevalence of intra-uterine death, hydrops, intra-uterine intravascular transfusions, cord haematocrit, cord bilirubin, number of liveborn babies, birth weight, neonatal death, hyaline membrane disease (HMD) and exchange transfusions. STUDY POPULATION AND SETTING: All mothers and babies with severe Rh incompatibility (defined as an amniotic optical density of 450 nm in the upper and upper-mid zone on the Liley chart at < 34 weeks' pregnancy duration, previous fetal hydrops or Rh-related intra-uterine death (IUD), fetal hydrops on ultrasound or a fetal haematocrit < 30% at cordocentesis) treated at Tygerberg Hospital between January 1980 and January 1993. There were 20 fetuses each in groups 1 and 3, and 17 in group 2. RESULTS: A total of 48 babies (84%) were liveborn and of these 74% survived the neonatal period. (ABSTRACT TRUNCATED AT 250 WORDS)


Subject(s)
Fetal Death/etiology , Rh Isoimmunization/prevention & control , Adult , Erythroblastosis, Fetal/immunology , Erythroblastosis, Fetal/mortality , Female , Humans , Hydrops Fetalis , Infant, Newborn , Pregnancy , Rh-Hr Blood-Group System
14.
MAGMA ; 3(3-4): 157-61, 1995.
Article in English | MEDLINE | ID: mdl-8749734

ABSTRACT

Five protocols were tested for quantification on in vivo two-dimensional spectroscopic imaging datasets. The datasets are duplo measurements from three individuals. The peaks for N-acetyl aspartate, creatines, and cholines were quantified. The first of the protocols is conventional integration of a selected interval around the peak. The others are various implementations of a Gauss-Newton-based least-squares time-domain fitting algorithm. Fitting a half-echo (free-induction decay curve, FID) to a full echo was compared; this was combined with or without filtering out the water signal using the Lanczos-Hankel singular-value decomposition (LHSVD). It appears that conventional integration yields consistent and accurate results in comparison to the fitting methods. The combination of LHSVD and echo fitting performs equally well; advantages and disadvantages are discussed. The protocols using FID fitting perform poorly with these experimental datasets.


Subject(s)
Image Processing, Computer-Assisted , Magnetic Resonance Spectroscopy/methods , Adult , Aspartic Acid/analogs & derivatives , Aspartic Acid/analysis , Choline/analysis , Creatine/analysis , Evaluation Studies as Topic , Humans , Least-Squares Analysis
15.
Magn Reson Imaging ; 13(1): 169-76, 1995.
Article in English | MEDLINE | ID: mdl-7898276

ABSTRACT

In this paper the results are presented of a joint European quantitative data-analysis study on a series of in vivo NMR time-domain test signals. The purpose of this study was to investigate, whether the quantitative MRS results from the various European biomedical research-centres can be made more comparable and reproducible. From the results of the study it can be concluded that in case of heavily overlapping NMR lines the quantifications should be done by some form of model function fitting and that, whenever possible, prior knowledge on the quantitative parameters should be incorporated into the quantification algorithms.


Subject(s)
Magnetic Resonance Spectroscopy , Quality Control
16.
NMR Biomed ; 7(5): 218-24, 1994 Aug.
Article in English | MEDLINE | ID: mdl-7848811

ABSTRACT

This study was conducted to verify the validity of using saturation factors obtained from unlocalized 31P spectra containing both chest wall and heart muscle signals for correcting human heart muscle phosphocreatine/beta-adenosine triphosphate (PCr/beta-ATP) ratios. Saturation factors and T1 relaxation times were determined from 31P magnetic resonance spectra of human chest wall and heart muscle simultaneously in healthy volunteers using one-dimensional spectroscopic imaging in combination with a two-dimensional ISIS sequence by using adiabatic 180 degrees inversion and adiabatic 90 degrees excitation pulses at 1.5 T. Blood corrected saturation factors for PCr/beta-ATP at a TR of 2.4 s were significantly different in heart muscle and chest wall muscle, 1.30 +/- 0.25 and 1.73 +/- 0.31, respectively (p < 0.05). T1 values for PCr and beta-ATP in heart muscle were 4.28 +/- 0.72 and 2.99 +/- 0.52 and in chest wall muscle 6.82 +/- 1.07 and 3.39 +/- 0.48, respectively. The T1(PCr)/T1(beta-ATP) ratios in chest wall and heart muscle were not identical. The mean PCr/beta-ATP ratios in heart and chest wall muscle of six healthy volunteers were 1.23 +/- 0.17 and 3.71 +/- 0.53, respectively.


Subject(s)
Magnetic Resonance Spectroscopy/methods , Muscle, Skeletal/metabolism , Myocardium/metabolism , Adenosine Triphosphate/metabolism , Adult , Data Interpretation, Statistical , Humans , Male , Models, Structural , Phosphocreatine/metabolism , Phosphorus Isotopes , Reproducibility of Results , Thorax
18.
J Mol Cell Cardiol ; 25(9): 1015-24, 1993 Sep.
Article in English | MEDLINE | ID: mdl-8283465

ABSTRACT

The aim of this study was to investigate whether intracellular free Mg2+ (Mgr), which increases during myocardial ischemia due to hydrolysis of ATP, remained elevated during reperfusion after a relatively short period of ischemia and thereby could account for temporary post-ischemic contractile dysfunction, often referred to as stunning. 31P-magnetic resonance (31P-NMR) spectroscopy was used to follow creatine phosphate, adenosine triphosphate, intracellular inorganic phosphate, intracellular pH and Mgr simultaneously with left ventricular developed pressure (LVDP) and coronary flow in isolated rat and rabbit hearts, which were perfused (37 degrees C) according to Langndorff. LVDP was measured in an isovolumic way by means of an intraventricular latex balloon. Rat hearts (300 beats/min) were made globally ischemic for 15 min and rabbit hearts (180 beats/min) for 15 or 20 min. All hearts were reperfused for 60 min. Control hearts were perfused for 75 min without being made ischemic. During ischemia Mgr (mmol/l) increased from 0.76 +/- 0.20 to 4.34 +2- 1.99 in the rat hearts, and from 0.72 +/- 0.22 to 2.18 +/- 1.06 (15 min) and 2.35 +/- 1.26 (20 min) in the rabbit hearts. During reperfusion Mgr in the three groups returned to the level of the control hearts within 7.5 min, and LVDP within 25 min. At the end of the reperfusion period ATP content amounted to 56 +/- 17% (rat hearts), 66 +/- 10% (rabbit hearts; 15 min ischemia group) and 61 +/- 7% (rabbit hearts; 20 min ischemia group) of the pre-ischemic levels. The results confirm that in vitro stunning is a short-lived phenomenon and indicate that an increased Mgr is not involved in this temporary mechanical dysfunction.


Subject(s)
Magnesium/metabolism , Myocardial Ischemia/physiopathology , Adenosine Triphosphate/metabolism , Animals , Heart/physiopathology , Magnetic Resonance Spectroscopy , Male , Myocardial Contraction , Myocardium/metabolism , Rabbits , Rats , Reperfusion Injury/metabolism
19.
Magn Reson Imaging ; 11(7): 1019-26, 1993.
Article in English | MEDLINE | ID: mdl-8231665

ABSTRACT

It is a well-known problem that metabolite maps, reconstructed from in vivo 1H MRSI data sets, may suffer from contamination caused by the presence of strong lipid signals. In the present investigation, the lipid problem was addressed by applying specific signal processing and data-analysis techniques, combined with pattern recognition based on the concept of the artificial neural network. In order to arrive at images, cleaned from lipid artifacts, we have applied our previously introduced iterative and noniterative time-domain fitting procedures. Furthermore, reduction in computational time of the image reconstructions could be realized by using information provided by a neural network classification of the spectra, calculated from the MRSI data sets.


Subject(s)
Lipids/analysis , Magnetic Resonance Spectroscopy/methods , Neural Networks, Computer , Artifacts , Brain Chemistry , Humans , Image Processing, Computer-Assisted , Pattern Recognition, Automated
20.
NMR Biomed ; 5(4): 171-8, 1992.
Article in English | MEDLINE | ID: mdl-1449952

ABSTRACT

Time-domain model function fitting techniques were applied to improve the reconstruction of metabolite maps from the data sets obtained from in vivo 1H spectroscopic imaging (SI) experiments. First, residual water-related signals were removed from the SI data sets by using SVD-based linear time-domain fitting based upon the HSVD (State Space) approach. Second, peak integrals of the metabolites of interest were obtained by quantifying the proton spin-echoes of the voxels by means of non-linear time-domain fitting based upon the maximum likelihood principle. Third, in order to save computational time, interpolation of the metabolite images (from size 32 x 32 to 128 x 128) was performed in the image-domain by applying one-dimensional cubic splines. It was found that the residual water signals can be almost completely removed from the SI data sets by applying the linear HSVD fitting method. Furthermore, it was found that voxel dependency of certain NMR parameters (e.g., variations of the spin-echo offset frequencies and/or phase factors) can be accounted for automatically by applying the nonlinear time-domain fitting technique. For that purpose it appeared to be essential to employ prior knowledge of the NMR spectral parameters.


Subject(s)
Brain/metabolism , Magnetic Resonance Spectroscopy/methods , Aspartic Acid/analogs & derivatives , Aspartic Acid/metabolism , Body Water/metabolism , Choline/metabolism , Creatine/metabolism , Humans , Lactates/metabolism , Lactic Acid , Mathematics
SELECTION OF CITATIONS