2.
Sci Rep ; 13(1): 19521, 2023 Nov 09.
Article in English | MEDLINE | ID: mdl-37945927

ABSTRACT

Investigations of the in-plane positioning capabilities of microscopes using machine-readable encoded patterned scales are presented. The scales have patterns that contain absolute position information, and adequate software accurately determines the in-plane position from the scale images captured by the microscope camera. This makes in-plane positioning experiments simple and fast. The scales and software used in this study are commercially available. We investigated different microscopy systems and found that positioning performance is a system issue that is not determined solely by stage performance. In some cases, our experiments revealed software or hardware glitches that limited the positioning performance, which we easily fixed. We have also shown that it is possible to investigate vibrations using this approach and quantify their impact on image blurring. This is, for example, useful for experimentally determining the settling time after a stage movement.

3.
Anal Chem ; 92(24): 15745-15756, 2020 12 15.
Article in English | MEDLINE | ID: mdl-33225709

ABSTRACT

The variable configuration of Raman spectroscopic platforms is one of the major obstacles in establishing Raman spectroscopy as a valuable physicochemical method within real-world scenarios such as clinical diagnostics. For such real world applications like diagnostic classification, the models should ideally be usable to predict data from different setups. Whether it is done by training a rugged model with data from many setups or by a primary-replica strategy where models are developed on a 'primary' setup and the test data are generated on 'replicate' setups, this is only possible if the Raman spectra from different setups are consistent, reproducible, and comparable. However, Raman spectra can be highly sensitive to the measurement conditions, and they change from setup to setup even if the same samples are measured. Although increasingly recognized as an issue, the dependence of the Raman spectra on the instrumental configuration is far from being fully understood and great effort is needed to address the resulting spectral variations and to correct for them. To make the severity of the situation clear, we present a round robin experiment investigating the comparability of 35 Raman spectroscopic devices with different configurations in 15 institutes within seven European countries from the COST (European Cooperation in Science and Technology) action Raman4clinics. The experiment was developed in a fashion that allows various instrumental configurations ranging from highly confocal setups to fibre-optic based systems with different excitation wavelengths. We illustrate the spectral variations caused by the instrumental configurations from the perspectives of peak shifts, intensity variations, peak widths, and noise levels. We conclude this contribution with recommendations that may help to improve the inter-laboratory studies.

4.
Opt Express ; 28(10): 14490-14502, 2020 May 11.
Article in English | MEDLINE | ID: mdl-32403488

ABSTRACT

Stimulated Raman Scattering (SRS) imaging can be hampered by non-resonant parasitic signals that lead to imaging artifacts and eventually overwhelm the Raman signal of interest. Stimulated Raman gain opposite loss detection (SRGOLD) is a three-beam excitation scheme capable of suppressing this nonlinear background while enhancing the resonant Raman signal. We present here a compact electro-optical system for SRGOLD excitation which conveniently exploits the idler beam generated by an optical parametric oscillator (OPO). We demonstrate its successful application for background suppressed SRS imaging in the fingerprint region. This system constitutes a simple and valuable add-on for standard coherent Raman laser sources since it enables flexible excitation and background suppression in SRS imaging.