Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 12 de 12
Filter
Add more filters










Publication year range
1.
Front Pharmacol ; 13: 900112, 2022.
Article in English | MEDLINE | ID: mdl-35935834

ABSTRACT

Background: Smoking is the leading cause of preventable death worldwide. It is responsible for several types of cancer, cardiovascular diseases, and diseases of the reproductive system, among others. Therefore, advances in research are increasingly necessary in order to make smoking cessation treatment more effective. Some studies have investigated the association of the nicotine metabolite ratio (NMR) with general characteristics and treatment outcomes. In the present study, the main aim was to evaluate the NMR in smoking patients from an Assistance Program of a tertiary cardiology hospital. Methodology: Serum samples were collected from 185 patients at T0 (while patients were still smoking and before starting pharmacological treatment). Cotinine and hydroxycotinine analytes were measured using liquid-chromatography tandem mass-spectrometry (LC-MS/MS). By looking at the relationship between hydroxycotinine and cotinine, we can obtain the NMR, with which it is possible to classify patients into slow metabolizers (NMR < 0.31), as well as normal or fast metabolizers (NMR ≥ 0.31). Results: From 185 patients, 55 were considered slow metabolizers and 130 as normal/fast. The metabolite averages were associated with the number of cigarettes smoked per day (p < 0.001 for cotinine and 0.023 hydroxycotinine). However, we were unable to analyze the association of the NMR with general and clinical characteristics of patients under smoking cessation treatment. Conclusion: We were able to evaluate the NMR, and to observe categories of metabolizers in Brazilian patients under pharmacological treatments. Thus, this study can contribute to the indication of a form of analysis, which might form part of the customization of smoking cessation treatments and, consequently, improve the success rates.

2.
Analyst ; 147(12): 2779-2792, 2022 Jun 13.
Article in English | MEDLINE | ID: mdl-35607977

ABSTRACT

A rapid and sensitive online restricted access molecularly imprinted solid-phase extraction method coupled to a liquid chromatography-mass spectrometry (LC-MS) system for simultaneous determination of serum bile acids as well as their taurine and glycine conjugates was developed. Reversible liver damage of workers exposed to volatile organic solvents can be investigated based on the level of the analyzed molecules. A restricted access molecularly imprinted polymer coated with bovine serum albumin (RAMIP-BSA) was synthesized and used as the extraction phase. The column switching liquid chromatography system was able to exclude about 100% of the macromolecules and extract/separate nine bile acids from blood human serum samples, in a total time of 40 minutes. The developed method was validated based on the Food and Drug Administration (FDA) guidelines, being linear for all the analytes in their respective analytical ranges (coefficients of determination higher than 0.99), with limits of detection (LOD) and quantification (LOQ) ranging from 2.0 to 5.7 µg L-1 and from 10.0 to 25.0 µg L-1, respectively. Suitable results for precision (relative standard deviation ranged from 3.2 to 14.5% and 0.7 to 14.8%, respectively for intra and inter-assay) and accuracy (relative error ranged from -14.8 to 14.2%; -13.8 to 14.3%) were obtained. The validated analytical method was applied to determine bile acids in serum samples of five workers occupationally exposed to volatile organic solvent, demonstrating its applicability in the assessment of these toxicants.


Subject(s)
Molecular Imprinting , Bile Acids and Salts , Chromatography, High Pressure Liquid/methods , Chromatography, Liquid/methods , Humans , Mass Spectrometry , Molecular Imprinting/methods , Polymers/chemistry , Solid Phase Extraction/methods , Solvents/chemistry
3.
J Chromatogr A ; 1669: 462931, 2022 Apr 26.
Article in English | MEDLINE | ID: mdl-35294893

ABSTRACT

Untreated samples were injected directly into a column switching system, an online SPE technique, using an extraction column packed with restricted access hybrid carbon nanotubes (RAHCNTs), a novel type of restricted access material, in an ultra-high performance liquid chromatography, coupled to a mass spectrometer (UHPLC-MS/MS). The synthesis of used restricted access material was relatively simple, quick, and reproducible, and had a high material yield. Compared to its predecessor, which is covered with bovine serum albumin (Restricted Access Carbon Nanotubes-RACNTs), RAHCNTs have improved performance when used for the analysis of organic compounds. These molecules have a greater adsorption capacity due to the insertion of hydrophilic monomers (tetraethyl orthosilicate (TEOS), 3-(trimethoxysilyl)propyl methacrylate (MPS), glycerol dimethacrylate (GDMA), and hydroxyethyl methacrylate (HEMA)) in the external layer. In addition, the formation of the hybrid material provides greater chemical and thermal stability, supporting wide pH and temperature ranges, and high concentrations of acidic and basic solutions. It also supports high proportions of organic solvents in the medium. Another significant advantage of the material is its longer lifetime, as it can be reused for approximately 500 analytical cycles without any loss of efficiency, versus 300 for RACNTs. In the method developed to determine anti-smoking drugs (varenicline and bupropion) simultaneously, as well as nicotine and some of their metabolites in human blood serum, the RAHCNTs were capable of retaining the analytes efficiently, whereas the macromolecules were excluded (almost 100%). The method was linear for all the determined analytes (coefficients of determination higher than 0.99), with limits of detection and quantification ranging from 0.6 to 2.5 µg L-1 and from 1.0 to 5.0 µg L-1, respectively. High extraction recovery values were obtained (higher than 88%), as well as inter and intra-assay accuracy and precision results that are in accordance with values recommended by the FDA. The method is promising for therapeutic monitoring and new personalized strategies for patients under antismoking treatment, using a small sample volume (100 µL). In addition, RAHCNTs are capable of simultaneously extracting analytes with very different physical-chemical characteristics.


Subject(s)
Nanotubes, Carbon , Smoking Cessation Agents , Adsorption , Chromatography, High Pressure Liquid , Humans , Nanotubes, Carbon/chemistry , Serum Albumin, Bovine/chemistry , Smoking Cessation Agents/analysis , Smoking Cessation Agents/metabolism , Tandem Mass Spectrometry
4.
Crit Rev Anal Chem ; 52(5): 933-948, 2022.
Article in English | MEDLINE | ID: mdl-33164555

ABSTRACT

Low concentrations of biomarkers as well as the complexity of biological samples make the clinical diagnoses of several diseases a challenging task. Sample preparation protocols remain a fundamental piece in the puzzle of analytical processes, and smart sorbents including molecularly imprinted polymers (MIPs) have been successfully used in this case. In this review, we depict the state of art for the rational design of MIPs to be used in solid phase extraction of disease biomarkers from biological samples. The topics are divided into (1) strategies for MIP syntheses, (2) setups for sample preparation protocols with MIPs, (3) the applications of these combined principles in the analyses of different classes of disease biomarkers, and (4) remaining challenges and future trends for the application of Molecular Imprinting Technology in sample preparation for clinical diagnosis.


Subject(s)
Molecular Imprinting , Polymers , Biomarkers , Molecular Imprinting/methods , Molecularly Imprinted Polymers , Solid Phase Extraction/methods
5.
J Chromatogr Sci ; 60(2): 201-207, 2022 Feb 16.
Article in English | MEDLINE | ID: mdl-33993236

ABSTRACT

Volatile organic compounds (VOCs), such as benzene, toluene and xylenes (BTX), are recognized as environmental contaminants due to their acute and chronic toxic effects, and toluene is a substance contained in products used in inhalants. In this way, methods able to determine these substances in non-invasive matrices offer great applicability for assessing acute exposure. In this study, a functionalized polymer, chloropropyltrimethoxysilane/polydimethylsiloxane, was evaluated as a potential material to be used in solid-phase microextraction for the quantification of BTX in urine by gas chromatography coupled to mass spectrometry (GC-MS). The method optimization was performed by using fractional factorial planning 2 (4-1) and the Doehlert's experiment. Desorption time and salinity were the most important factors that impact the sensitivity of the method. Spectroscopic and thermogravimetric characterization demonstrated the functionalization of the material and its thermal stability up to 390°C. This allowed it to be used for ~60 analytical cycles without loss of efficiency. The proposed method demonstrated a satisfactory analytical performance to determine the VOCs studied. The protocol agrees with the principles of green analytical chemistry since the procedure reduced the reagents consumed and wastes generated. It represents a promising tool for acute exposure assessment to BTX since urine tests demonstrated its applicability.


Subject(s)
Volatile Organic Compounds , Xylenes , Benzene/analysis , Gas Chromatography-Mass Spectrometry/methods , Solid Phase Microextraction/methods , Toluene/analysis , Volatile Organic Compounds/analysis , Xylenes/analysis
6.
Toxicol Mech Methods ; 31(1): 18-32, 2021 Jan.
Article in English | MEDLINE | ID: mdl-33081560

ABSTRACT

The need for reliable results in Toxicological Analysis is recognized and required worldwide. The analytical validation ensures that a method will provide trustworthy information about a particular sample when applied in accordance with a predefined protocol, being able to determine a specific analyte at a distinct concentration range for a well-defined purpose. The driving force for developing method validation for bioanalytical projects comes from the regulatory agencies. Thus, the approach of this work is to present theoretical and practical aspects of method validation based on the analysis objective, whether for prevention or diagnosis. Although various legislative bodies accept differing interpretations of requirements for validation, the process for applying validation criteria should be adaptable for each scientific intent or analytical purpose.


Subject(s)
Research Design , Toxicity Tests , Animals , Calibration , Humans , Limit of Detection , Quality Control , Reproducibility of Results , Research Design/standards , Risk Assessment , Toxicity Tests/standards
7.
Anal Bioanal Chem ; 412(11): 2465-2475, 2020 Apr.
Article in English | MEDLINE | ID: mdl-32025768

ABSTRACT

This manuscript describes the development of the restricted access carbon nanotube (RACNT) as a selective stationary phase for microextraction by packed sorbent (MEPS) to determine antipsychotics (chlorpromazine, clozapine, olanzapine, and quetiapine) in untreated plasma samples from schizophrenic patients by ultra-high liquid chromatography-tandem mass spectrometry (UHPLC-MS/MS). The synthesis was achieved by chemically covering commercial multi-walled carbon nanotubes with bovine serum albumin (BSA) to subsequently pack the material in a polyethylene conical tube (1000 µL). The RACNTs' sorbents were able to exclude about 97% of the plasma proteins, maintaining the same performance for about 100 assays. The MEPS variables (sample pH, draw-eject cycles, desorption and phase cleanup) were evaluated to improve sensibility and selectivity. The MEPS/UHPLC-MS/MS method was linear at concentrations ranging from the lower limit of quantification (10.0 ng mL-1) to the upper limit of quantification (200-700 ng mL-1) with coefficients of determinations higher than 0.99. The precision assays presented relative standard deviation (RSD) values lower than 13%, and the accuracy assays presented relative error (RE) values that ranged from - 8.01 to 11.53%. Neither significant matrix effects nor carryover was observed. The developed method was successfully applied to determine antipsychotics drugs for therapeutic drug monitoring of schizophrenic patients.


Subject(s)
Antipsychotic Agents/blood , Drug Monitoring/methods , Nanotubes, Carbon/chemistry , Solid Phase Microextraction/methods , Tandem Mass Spectrometry/methods , Antipsychotic Agents/isolation & purification , Chromatography, High Pressure Liquid/methods , Humans , Limit of Detection , Schizophrenia/drug therapy
8.
Environ Sci Pollut Res Int ; 27(4): 4219-4226, 2020 Feb.
Article in English | MEDLINE | ID: mdl-31828701

ABSTRACT

The present study assessed the exposure to methylparaben (MP) and propylparaben (PP) from antiperspirants in serum of 24 women aged 20-30 years old and an in vitro skin assay. An effective liquid chromatography-tandem mass spectrometry method for the determination of MP and PP levels in serum was developed and validated in the range of 10-100 µg/L; the method was fast, simple, sensitive, linear, precise, and accurate. In addition, a simple and rapid liquid chromatography-ultraviolet detection method for the determination of MP and PP levels in antiperspirants was developed and validated in the range of 2-26 mg/L, which presented satisfactory linearity, precision, and accuracy. Using these two methods, 20 commercial antiperspirants were evaluated, and only three showed MP and PP in the formulation. The antiperspirant containing 0.2% and 0.1% w/w MP and PP, respectively, was given to the volunteers, to estimate the internal dose, and submitted to a pig ear skin permeation assay in Franz diffusion cells, presenting a permeation flux of 32% for MP and 71% for PP. In this assay, both MP and PP permeated the skin; however, there was no correlation between antiperspirant use and paraben serum concentration in the volunteers. Graphical abstract.


Subject(s)
Antiperspirants/analysis , Parabens/analysis , Skin Absorption , Skin , Adult , Animals , Chromatography, Liquid , Female , Humans , Serum/chemistry , Swine , Young Adult
9.
Mikrochim Acta ; 186(9): 647, 2019 08 27.
Article in English | MEDLINE | ID: mdl-31456048

ABSTRACT

Restricted-access nanoparticles (RANPs) were prepared from bovine serum albumin by coacervation. They have an average sized of 311 nm. They were characterized and used to capture the ß-blockers atenolol, metoprolol and propranolol from untreated biological samples. It is shown that both high protein affinity drugs (propranolol) and low protein affinity drugs (atenolol) could be rapidly extracted from plasma. This is revealed by kinetic and isothermal adsorption studies. On the other hand, almost all proteins from the sample were excluded. This demonstrates the efficiency of RANPs as restricted-access material. Sample preparation was carried out by solid phase microextraction using a probe obtained by the fixation of the RANPs at the end of a glass capillary. Atenolol (in concentrations from 100 to 1200 µg L-1), metoprolol (from 80 to 1000 µg L-1) and propranolol (from 15 to 200 µg L-1) were extracted from spiked plasma samples and analyzed by LC MS/MS without using a separation column. Correlation coefficients >0.99, good precision, accuracy, robustness, and lack of memory effects were observed for all of the analytes. The detection limits (at an S/N of 3) are 25.6, 14.6, and 3.8 µg L-1 for atenolol, metoprolol and propranolol, respectively. Ten samples can be simultaneously extracted within ∼15 min. Plasma samples of patients undergoing medical treatment were successfully analyzed with the method. Graphical abstract Schematic representation of a bovine serum albumin-based restricted access nanoparticle that exclude proteins from a human plasma sample but capture the small analytes.


Subject(s)
Adrenergic beta-Antagonists/blood , Nanoparticles/chemistry , Serum Albumin, Bovine/chemistry , Animals , Cattle , Chromatography, Liquid , Humans , Particle Size , Surface Properties , Tandem Mass Spectrometry
10.
J Chromatogr A ; 1528: 41-52, 2017 Dec 15.
Article in English | MEDLINE | ID: mdl-29102378

ABSTRACT

A novel analytical method was developed to determine 5 antihypertensive drugs of different pharmacological classes (angiotensin-converting enzyme inhibitors, calcium channel blockers, α-2 adrenergic receptor agonists, angiotensin II receptor blockers, and aldosterone receptor antagonists) and some of their metabolites in human serum. The untreated samples were directly analyzed in a column switching system using an extraction column packed with restricted access carbon nanotubes (RACNTs) in an ultra-high performance liquid chromatography coupled to a mass spectrometer (UHPLC-MS/MS). The RACNTs column was able to exclude approximately 100% of proteins from the samples in 2.0min, maintaining the same performance for about 300 analytical cycles. The method was validated in accordance with Food and Drug Administration (FDA) guidelines, being linear for all the determined analytes in their respective analytical ranges (coefficients of determination higher than 0.99) with limits of detection (LODs) and quantification (LOQs) ranging from 0.09 to 10.85µgL-1 and from 0.30 to 36.17µgL-1, respectively. High recovery values (88-112%) were obtained as well as suitable results for inter and intra-assay accuracy and precision. The method provided an analytical frequency of 5 samples per hour, including the sample preparation and separation/detection steps. The validated method was successfully used to analyze human serum samples of patients undergoing treatment with antihypertensive drugs, being useful for pharmacometabolomic, pharmacogenomic, and pharmacokinetic studies.


Subject(s)
Antihypertensive Agents/blood , Antihypertensive Agents/isolation & purification , Blood Chemical Analysis/methods , Chromatography, High Pressure Liquid/instrumentation , Nanotubes, Carbon/chemistry , Blood Chemical Analysis/instrumentation , Humans , Limit of Detection , Reproducibility of Results , Tandem Mass Spectrometry
11.
Anal Chim Acta ; 959: 43-65, 2017 Mar 22.
Article in English | MEDLINE | ID: mdl-28159105

ABSTRACT

The determination of organic and inorganic analytes from biological samples need efficient sample preparation procedures in order to capture the analyte in a media with many macromolecules, which can cause analytical errors and problems with the instruments. Thus, "intelligent" sorbents, called restricted access materials (RAMs), have been widely used with these samples, due to their ability to retain analytes and exclude macromolecules. These materials have been obtained by modifying the external surfaces of conventional sorbents (e.g. polymers, carbon nanotubes, active carbon, and silica-based materials) with hydrophilic groups (chemical barrier), as well as by the presence of small pores (physical barrier) accessible only to low molecular weight molecules. Supramolecular solvents (SUPRAs) have also been used as RAMs, due to their abilities to exclude proteins according to size or through precipitation with the solvents. Therefore, due to the relevance of these materials, this review presents an overview of the most recent advances in obtaining RAMs based on silica, polymers, carbon nanotubes, (activated) carbon, and solvents, as well as their applications in biological sample preparation.


Subject(s)
Charcoal , Nanotubes, Carbon , Polymers , Silicon Dioxide , Solvents , Specimen Handling/methods , Hydrophobic and Hydrophilic Interactions , Macromolecular Substances
12.
Food Chem ; 225: 98-106, 2017 Jun 15.
Article in English | MEDLINE | ID: mdl-28193438

ABSTRACT

This paper describes, for the first time, the use of restricted access carbon nanotubes (RACNTs) in the analysis of tetracyclines from milk samples, in a multidimensional liquid chromatographic system. Milk samples were initially acidified and centrifuged, and then the supernatant was directly analyzed in a column switching system in backflush configuration employing an extraction column of RACNTs. The sorbent was able to exclude all the remained proteins in less than 2.0min. The method was linear from 50 to 200µgL-1 and the coefficients of determination (r2) were 0.997, 0.992, 0.994 and 0.998 for oxytetracycline (OXI), tetracycline (TC), chlortetracycline (CTC) and doxycycline (DOX), respectively. The analytical range included the maximum residue limits established by the regulatory agency.


Subject(s)
Chromatography, Liquid , Nanotubes, Carbon/chemistry , Tetracyclines/isolation & purification , Animals , Milk/chemistry , Tetracyclines/analysis , Tetracyclines/chemistry
SELECTION OF CITATIONS
SEARCH DETAIL
...