Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 4 de 4
Filter
Add more filters










Database
Language
Publication year range
1.
Diagnostics (Basel) ; 13(4)2023 Feb 13.
Article in English | MEDLINE | ID: mdl-36832199

ABSTRACT

PURPOSE: To assess the technical (TS) and clinical success (CS) of CT fluoroscopy-guided drainage (CTD) in patients with symptomatic deep pelvic fluid collections following colorectal surgery. METHODS: A retrospective analysis (years 2005 to 2020) comprised 43 drain placements in 40 patients undergoing low-dose (10-20 mA tube current) quick-check CTD using a percutaneous transgluteal (n = 39) or transperineal (n = 1) access. TS was defined as sufficient drainage of the fluid collection by ≥50% and the absence of complications according to the Cardiovascular and Interventional Radiological Society of Europe (CIRSE). CS comprised the marked reduction of elevated laboratory inflammation parameters by ≥50% under minimally invasive combination therapy (i.v. broad-spectrum antibiotics, drainage) within 30 days after intervention and no surgical revision related to the intervention required. RESULTS: TS was gained in 93.0%. CS was obtained in 83.3% for C-reactive Protein and in 78.6% for Leukocytes. In five patients (12.5%), a reoperation due to an unfavorable clinical outcome was necessary. Total dose length product (DLP) tended to be lower in the second half of the observation period (median: years 2013 to 2020: 544.0 mGy*cm vs. years 2005 to 2012: 735.5 mGy*cm) and was significantly lower for the CT fluoroscopy part (median: years 2013 to 2020: 47.0 mGy*cm vs. years 2005 to 2012: 85.0 mGy*cm). CONCLUSIONS: Given a minor proportion of patients requiring surgical revision due to anastomotic leakage, the CTD of deep pelvic fluid collections is safe and provides an excellent technical and clinical outcome. The reduction of radiation exposition over time can be achieved by both the ongoing development of CT technology and the increased level of interventional radiology (IR) expertise.

2.
Diagnostics (Basel) ; 11(5)2021 Apr 26.
Article in English | MEDLINE | ID: mdl-33926046

ABSTRACT

PURPOSE: To evaluate technical outcome, diagnostic yield and safety of computed tomographic fluoroscopy-guided percutaneous core needle biopsies in patients with mediastinal masses. METHODS: Overall, 155 CT fluoroscopy-guided mediastinal core needle biopsies, performed from March 2010 to June 2020 were included. Size of lesion, size of needle, access path, number of success, number of biopsies per session, diagnostic yield, patient's position, effective dose, rate of complications, tumor localization, size of tumor and histopathological diagnosis were considered. Post-interventional CT was performed, and patients observed for any complications. Complications were classified per the Society of Interventional Radiology (SIR). RESULTS: 148 patients (age, 54.7 ± 18.2) underwent 155 CT-fluoroscopy-guided percutaneous biopsies with tumors in the anterior (114; 73.5%), middle (17; 11%) and posterior (24; 15.5%) mediastinum, of which 152 (98%) were technically successful. For placement of the biopsy needle, in 82 (52.9%) procedures a parasternal trajectory was chosen, in 36 (23.3%) a paravertebral access, in 20 (12.9%) through the lateral intercostal space and in 17 (11%) the thoracic anterior midline, respectively. A total of 136 (89.5%) of the biopsies were considered adequate for a specific histopathologic analysis. Total DLP (dose-length product) was 575.7 ± 488.8 mGy*cm. Mean lesion size was 6.0 ± 3.3 cm. Neoplastic pathology was diagnosed in 115 (75.7%) biopsies and 35 (23%) biopsy samples showed no evidence of malignancy. Minor complications were observed in 18 (11.6%) procedures and major pneumothorax requiring drainage insertion in 3 interventions (1.9%). CONCLUSION: CT fluoroscopy-guided percutaneous core needle biopsy of mediastinal masses is an effective and safe procedure for the initial assessment of patients with mediastinal tumors.

3.
Scand J Urol ; 54(3): 241-247, 2020 Jun.
Article in English | MEDLINE | ID: mdl-32449437

ABSTRACT

Purpose: The aim of the present retrospective single-center study is to evaluate the diagnostic performance of multiparametric ultrasonography for characterizing testicular tumors.Method: Forty-nine patients with testicular tumors, 36 of malignant vs 13 of benign entity, were included in this retrospective single-center study on whom multiparametric sonography, encompassing native B-mode, Color Doppler, contrast-enhanced ultrasound (CEUS) and elastography, was performed between 2011-2018. In 48 of 49 patients, findings from multiparametric analysis were correlated with histopathological results. The applied contrast agent for CEUS was a second-generation blood pool agent. Ultrasonography examinations were performed and interpreted by a single experienced radiologist with more than 15 years of experience (EFSUMB Level 3).Results: Multiparametric ultrasonography was successfully performed in all included patients without any adverse effects. Concomitant testicular microlithiasis, rapid arterial wash-in, elevated values for perfusion quantification - Peak Enhancement (PE), Wash-in Area Under the Curve (WiAUC) and Wash-in Perfusion Index (WiPI) - and higher shear wave velocities were significantly associated with malignancy.Conclusions: Multiparametric ultrasonography depicts a non-ionizing, directly accessible and cost-effective imaging modality that allows for the extensive characterization of testicular tumors, thereby helping to discriminate between malignant and benign entity of testicular tumors.


Subject(s)
Testicular Neoplasms/diagnostic imaging , Adolescent , Adult , Aged , Aged, 80 and over , Child , Humans , Male , Middle Aged , Retrospective Studies , Ultrasonography/methods , Young Adult
4.
Neuroradiology ; 61(2): 129-136, 2019 Feb.
Article in English | MEDLINE | ID: mdl-30402744

ABSTRACT

PURPOSE: Development of a warp-based automated brain segmentation approach of 3D fluid-attenuated inversion recovery (FLAIR) images and comparison to 3D T1-based segmentation. METHODS: 3D FLAIR and 3D T1-weighted sequences of 30 healthy subjects (mean age 29.9 ± 8.3 years, 8 female) were acquired on the same 3T MR scanner. Warp-based segmentation was applied for volumetry of total gray matter (GM), white matter (WM), and 116 atlas regions. Segmentation results of both sequences were compared using Pearson correlation (r). RESULTS: Correlation of GM segmentation results based on FLAIR and T1 was overall good for cortical structures (mean r across all cortical structures = 0.76). Comparatively weaker results were found in the occipital lobe (r = 0.77), central region (mean r = 0.58), basal ganglia (mean r = 0.59), thalamus (r = 0.30), and cerebellum (r = 0.73). FLAIR segmentation underestimated volume of the central region compared to T1, but showed a better anatomic concordance with the occipital lobe on visual review and subcortical structures, when also compared to manual segmentation. Visual analysis of FLAIR-based WM segmentation revealed frequent misclassification of regions of high signal intensity as GM. CONCLUSION: Warp-based FLAIR segmentation yields comparable results to T1 segmentation for most cortical GM structures and may provide anatomically more congruent segmentation of subcortical GM structures. Selected cortical regions, especially the central region and total WM, seem to be underestimated on FLAIR segmentation.


Subject(s)
Brain Mapping/methods , Image Processing, Computer-Assisted/methods , Imaging, Three-Dimensional/methods , Magnetic Resonance Imaging/methods , Adult , Female , Humans , Male , Middle Aged
SELECTION OF CITATIONS
SEARCH DETAIL
...