Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 20 de 45
Filter
1.
Front Microbiol ; 15: 1341152, 2024.
Article in English | MEDLINE | ID: mdl-38410386

ABSTRACT

The presented study protocol outlines a comprehensive investigation into the interplay among the human microbiota, volatilome, and disease biomarkers, with a specific focus on Behçet's disease (BD) using methods based on explainable artificial intelligence. The protocol is structured in three phases. During the initial three-month clinical study, participants will be divided into control and experimental groups. The experimental groups will receive a soluble fiber-based dietary supplement alongside standard therapy. Data collection will encompass oral and fecal microbiota, breath samples, clinical characteristics, laboratory parameters, and dietary habits. The subsequent biological data analysis will involve gas chromatography, mass spectrometry, and metagenetic analysis to examine the volatilome and microbiota composition of salivary and fecal samples. Additionally, chemical characterization of breath samples will be performed. The third phase introduces Explainable Artificial Intelligence (XAI) for the analysis of the collected data. This novel approach aims to evaluate eubiosis and dysbiosis conditions, identify markers associated with BD, dietary habits, and the supplement. Primary objectives include establishing correlations between microbiota, volatilome, phenotypic BD characteristics, and identifying patient groups with shared features. The study aims to identify taxonomic units and metabolic markers predicting clinical outcomes, assess the supplement's impact, and investigate the relationship between dietary habits and patient outcomes. This protocol contributes to understanding the microbiome's role in health and disease and pioneers an XAI-driven approach for personalized BD management. With 70 recruited BD patients, XAI algorithms will analyze multi-modal clinical data, potentially revolutionizing BD management and paving the way for improved patient outcomes.

2.
J Breath Res ; 17(4)2023 07 12.
Article in English | MEDLINE | ID: mdl-37379826

ABSTRACT

SARS-CoV-2 is expected to cause metabolic alterations due to viral replication and the host immune response resulting in increase of cytokine secretion and cytolytic activity. The present prospective observational study is addressed at exploring the potentialities of breath analysis in discrimination between patients with a documented previous history of symptomatic SARS-CoV-2 infection and, at the moment of the enrollment, exhibiting a negative nasopharyngeal swab and acquired immunity (post-COVID) and healthy subjects with no evidence of previous SARS-CoV-2 infection (no-COVID). The main purpose is to understand if traces of metabolic alterations induced during the acute phase of the infection are still detectable after negativization, in the form of a characteristic volatile organic compound (VOC) pattern. An overall number of 60 volunteers aged between 25 and 70 years were enrolled in the study (post-COVID: n.30; no-COVID: n. 30), according to well-determined criteria. Breath and ambient air samples were collected by means of an automated sampling system (Mistral) and analyzed by thermal desorption-gas chromatography-mass spectrometry (TD-GC/MS). Statistical tests (Wilcoxon/Kruskal-Wallis test) and multivariate data analysis (principal component analysis (PCA), linear discriminant analysis) were performed on data sets. Among all compounds detected (76 VOCs in 90% of breath samples), 5 VOCs (1-propanol, isopropanol, 2-(2-butoxyethoxy)ethanol, propanal and 4-(1,1-dimethylpropyl)phenol) showed abundances in breath samples collected from post-COVID subjects significantly different with respect to those collected from no-COVID group (Wilcoxon/Kruskal-Wallis test,p-values <0.05). Although not completely satisfactory separation between the groups was obtained, variables showing significant differences between the two groups and higher loadings for PCA are recognized biomarkers of COVID-19, according to previous studies in literature. Therefore, based on the outcomes obtained, traces of metabolic alterations induced by SARS-CoV-2 infection are still detectable after negativization. This evidence raises questions about the eligibility of post-COVID subjects in observational studies addressed at the detection of COVID-19. (Ethical Committee Registration number: 120/AG/11).


Subject(s)
COVID-19 , Volatile Organic Compounds , Humans , Adult , Middle Aged , Aged , Breath Tests/methods , SARS-CoV-2 , Exhalation , Volatile Organic Compounds/analysis
3.
Environ Res ; 211: 113038, 2022 08.
Article in English | MEDLINE | ID: mdl-35231456

ABSTRACT

There are important questions surrounding the potential contribution of outdoor and indoor air quality in the transmission of SARS-CoV-2 and perpetuation of COVID-19 epidemic waves. Environmental health may be a critical component of COVID-19 prevention. The public health community and health agencies should consider the evolving evidence in their recommendations and statements, and work to issue occupational guidelines. Evidence coming from the current epidemiological and experimental research is expected to add knowledge about virus diffusion, COVID-19 severity in most polluted areas, inter-personal distance requirements and need for wearing face masks in indoor or outdoor environments. The COVID-19 pandemic has highlighted the need for maintaining particulate matter concentrations at low levels for multiple health-related reasons, which may also include the spread of SARS-CoV-2. Indoor environments represent even a more crucial challenge to cope with, as it is easier for the SARS-COV2 to spread, remain vital and infect other subjects in closed spaces in the presence of already infected asymptomatic or mildly symptomatic people. The potential merits of preventive measures, such as CO2 monitoring associated with natural or controlled mechanical ventilation and air purification, for schools, indoor public places (restaurants, offices, hotels, museums, theatres/cinemas etc.) and transportations need to be carefully considered. Hospital settings and nursing/retirement homes as well as emergency rooms, infectious diseases divisions and ambulances represent higher risk indoor environments and may require additional monitoring and specific decontamination strategies based on mechanical ventilation or air purification.


Subject(s)
Air Pollution, Indoor , COVID-19 , COVID-19/epidemiology , COVID-19/prevention & control , Humans , Pandemics/prevention & control , Particulate Matter , RNA, Viral , SARS-CoV-2
5.
Environ Res ; 204(Pt B): 112007, 2022 03.
Article in English | MEDLINE | ID: mdl-34509482

ABSTRACT

BACKGROUND: In cities suffering from heavy environmental pressure or pollution, it is extremely important to rapidly access municipal demographics that can be used as indicators of population health status. Among those, mortality rates represent the most reliable data as they are officially retained and available to municipality with high level of details, thus allowing epidemiological comparison between different neighborhoods of the city across several years. Our study was aimed at validating and propose as universally applicable approach the use of municipal demographics as first-line tool to rapidly assess population health and drive health policies or urban planning in cities characterized by heavy environmental pressure. The case study of Taranto has been chosen due to the presence of the biggest European steel plant since 1960s resulting in heavy burden on environment and population health. METHODS: We have performed an ecological study on general mortality data due to all causes, specific by gender, age groups and disaggregated at sub-municipal level (highest data granularity) into neighborhoods from 2011 to 2020 by using official demographics related to all people living in Taranto available at General Registry Office of the municipality. A preliminary analysis comparing data available at Municipality and those provided by the Italian National Institute of Statistics (ISTAT) was performed and confirmed the high level of reliability of the municipal source of data. For comparative analyses, we used Regional demographics and mortality from ISTAT. Indirect age-standardized mortality ratios (SMR; CI 90% and 95%), specific for gender and neighborhoods, were calculated in reference to the city of Taranto and Apulia Region; direct age-standardized and neighborhoods mortality rates were computed on city population. RESULTS: The city of Taranto shows relevant inequalities in terms of mortality between the northern neighborhoods, closest to the industrial area (Paolo VI, Tamburi and Città Vecchia-Borgo), with excess mortality highlighted across 10 years described by SMRs always higher than those of the entire Apulia region, with peaks exceeding 50% between 2015 and 2017 both in women and men. The significant excesses of mortality have increased from 2011 to 2020 and progressively extended across several neighborhoods of Taranto city. Compared to the Apulia region, in the 3 Northern neighborhoods of the city (Paolo VI, Tamburi and Città Vecchia-Borgo) a total of 1020 excess deaths were recorded from 2011 to 2019 in both males and females (showing statistical significance), with a peak of 68% mortality excess in 2019 for men living in Paolo VI district. CONCLUSION: The use of official mortality data allows a timely, reliable and costless assessment of population health in cities heavily impacted by environmental pollution like Taranto.


Subject(s)
Environmental Pollution , Industry , Cities , Female , Health Status , Humans , Italy/epidemiology , Male , Mortality , Reproducibility of Results
6.
Environ Res ; 202: 111560, 2021 11.
Article in English | MEDLINE | ID: mdl-34224708

ABSTRACT

In order to avoid SARS-CoV-2 transmission inside educational buildings and promote the safe reopening of schools, the Italian Government, in line with the other European countries and in accordance with the WHO recommendations, adopted a contingency plan including actions able to guarantee adequate air ventilation in classrooms. Therefore, in this pilot study, a surveillance activity based on the real-time monitoring of CO2 levels as a proxy of SARS-CoV-2 transmission risk, was conducted inside 9 schools (11 classrooms) located in Apulia Region (South of Italy) during the reopening of schools after the lockdown due to COVID-19 pandemic. More specifically, monitoring activities and data treatment were conducted to evaluate the initial scenario inside the classrooms (first stage of evaluation) and the potential improvements obtained by applying a detailed operating protocol of air ventilation based on specific actions and the simultaneous real time visualization of CO2 levels by non-dispersive infrared (NDIR) sensors (second stage of evaluation). Although, during the first evaluation stage, air ventilation through the opening of windows and doors was guaranteed, 6 (54%) classrooms showed mean values of CO2 higher than 1000 ppm and all classrooms exceeded the recommended CO2 concentration limit value of 700 ppm. The development and implementation of tailored ventilation protocol including the real time visualization of CO2 levels allowed to depict better scenariosAn overall improvement of CO2 levels was indeed registered for all classrooms where teachers were compliant and helpful in the management of the air ventilation strategy. Therefore, this study reports the first evidence-based measures demonstrating that, with the exception of few environments affected by structural limits, the real-time visualization and monitoring of CO2 concentrations allowes effective air exchanges to be implemented and contributes to prevent SARS-CoV-2 transmission. Moreover, on the basis of the monitoring outcomes and in order to ensure adequate air ventilation in educational buildings, a 4 level-risk classification including specific corrective actions for each level was provided.


Subject(s)
Air Pollution, Indoor , COVID-19 , Air Pollution, Indoor/analysis , Carbon Dioxide/analysis , Communicable Disease Control , Humans , Pandemics , Pilot Projects , SARS-CoV-2 , Schools , Ventilation
7.
Sci Total Environ ; 791: 148135, 2021 Oct 15.
Article in English | MEDLINE | ID: mdl-34118667

ABSTRACT

In this study an innovative sensing network consisting of eight photoionization detectors, meteorological sensors, a video camera and a telephonic system able to systematize the population complaints was developed for the monitoring of odor emissions. The development of monitoring approaches with high temporal and spatial resolution and actively involving citizens, is strategic in areas where relevant and also short-term emissive events frequently occur and the conventional approaches fail due to the high variability of fugitive emissions. Moreover, even if unpleasant odors are not necessarily direct triggers of health effects, they could be associated with the release of other harmful compounds. Monitoring approaches also involving citizens are thus strategic tools because odors annoyance perceived by population may be a potential health risk warning. Therefore, the developed sensing network was set up in Val d'Agri (Basilicata, Italy) where a petroleum pre-treatment plant (COVA) rises in a rural and inhabited area. The data collected during the monitoring campaign from the 16th February to the 30th July 2017, showed Total Volatile Organic Compounds (TVOCs) concentrations decreasing moving away from the plant and up to five times higher than levels registered in the closest municipality (Viggiano). Moreover, recurrent short-term critical events characterized by concentration values far above the average of the period and with maximum values ranging from 0.92 to 1.89 ppm, were registered in correspondence with high levels of benzene (up to 23.9 µg/m3) and anemometric conditions able to transport pollutants from COVA to each receptor site. The spatial and temporal distribution of TVOC concentrations proved to be affected by the distance from COVA, wind direction and industrial activities verified using video reportage and citizen claims. Therefore, the developed approach has proven to be a useful tool to credit people's perception of odors and also to quantify citizen exposure to VOCs during short-term events.


Subject(s)
Air Pollutants , Air Pollution , Petroleum , Volatile Organic Compounds , Air Pollutants/analysis , Air Pollution/analysis , Cities , Environmental Monitoring , Humans
8.
Environ Res ; 197: 111131, 2021 06.
Article in English | MEDLINE | ID: mdl-33865819

ABSTRACT

The adverse effects of fine particulate matter (PM) and many volatile organic compounds (VOCs) on human health are well known. Fine particles are, in fact, those most capable of penetrating in depth into the respiratory system. People spend most of their time indoors where concentrations of some pollutants are sometimes higher than outdoors. Therefore, there is the need to ensure a healthy indoor environment and for this purpose the use of an air purifier can be a valuable aid especially now since it was demonstrated that indoor air quality has a high impact on spreading of viral infections such as that due to SARS-COVID19. In this study, we tested a commercial system that can be used as an air purifier. In particular it was verified its efficiency in reducing concentrations of PM10 (particles with aerodynamic diameter less than 10 µm), PM2.5 (particles with aerodynamic diameter less than 2.5 µm), PM1 (particles with aerodynamic diameter less than 1 µm), and particles number in the range 0.3 µm-10 µm. Furthermore, its capacity in reducing VOCs concentration was also checked. PM measurements were carried out by means of a portable optical particle counter (OPC) instrument simulating the working conditions typical of a household environment. In particular we showed that the tested air purifier significantly reduced both PM10 and PM2.5 by 16.8 and 7.25 times respectively that corresponds to a reduction of about 90% and 80%. A clear reduction of VOCs concentrations was also observed since a decrease of over 50% of these gaseous substances was achieved.


Subject(s)
Air Filters , Air Pollutants , Air Pollution, Indoor , COVID-19 , Volatile Organic Compounds , Aerosols , Air Pollutants/analysis , Air Pollution, Indoor/analysis , Environmental Monitoring , Humans , Particle Size , Particulate Matter/analysis , SARS-CoV-2 , Volatile Organic Compounds/analysis
9.
Environ Res ; 198: 111200, 2021 07.
Article in English | MEDLINE | ID: mdl-33901446

ABSTRACT

The relevance of airborne exposure to SARS-CoV-2 in indoor environments is a matter of research and debate, with special importance for healthcare low-risk settings. Experimental approaches to the bioaerosol sampling are neither standardized nor optimized yet, leading in some cases to limited representativity of the temporal and spatial variability of viral presence in aerosols. Airborne viral viability moreover needs to be assessed. A study has been conducted collecting five 24-h PM10 samples in a COVID-19 geriatric ward in late June 2020, and detecting E and RdRp genes by RT-qPCR with a Ct between 36 and 39. The viral RNA detection at Ct = 36 was related to the maximal numerosity of infected patients hosted in the ward. Lacking a direct infectivity assessment for the collected samples an experimental model has been defined, by seeding twelve nasopharyngeal swab extracts from COVID-19 positive patients on Vero E6 cells; only the four extracts with a viral load above E+10 viral copies (approximately Ct<24) have been able to establish a persistent infection in vitro. Therefore, the cytopathic effect, a key feature of residual infectivity, could be considered unlikely for the environmental PM10 samples showing amplification of viral RNA at Ct = 36 or higher. A standardization of airborne SARS-CoV-2 long-term monitoring and of environmental infectivity assessment is urgently needed.


Subject(s)
Air Pollution, Indoor , COVID-19 , Aerosols , Aged , Environmental Monitoring , Humans , SARS-CoV-2
10.
Molecules ; 25(24)2020 Dec 10.
Article in English | MEDLINE | ID: mdl-33321824

ABSTRACT

Despite promising results obtained in the early diagnosis of several pathologies, breath analysis still remains an unused technique in clinical practice due to the lack of breath sampling standardized procedures able to guarantee a good repeatability and comparability of results. The most diffuse on an international scale breath sampling method uses polymeric bags, but, recently, devices named Mistral and ReCIVA, able to directly concentrate volatile organic compounds (VOCs) onto sorbent tubes, have been developed and launched on the market. In order to explore performances of these new automatic devices with respect to sampling in the polymeric bag and to study the differences in VOCs profile when whole or alveolar breath is collected and when pulmonary wash out with clean air is done, a tailored experimental design was developed. Three different breath sampling approaches were compared: (a) whole breath sampling by means of Tedlar bags, (b) the end-tidal breath collection using the Mistral sampler, and (c) the simultaneous collection of the whole and alveolar breath by using the ReCIVA. The obtained results showed that alveolar fraction of breath was relatively less affected by ambient air (AA) contaminants (p-values equal to 0.04 for Mistral and 0.002 for ReCIVA Low) with respect to whole breath (p-values equal to 0.97 for ReCIVA Whole). Compared to Tedlar bags, coherent results were obtained by using Mistral while lower VOCs levels were detected for samples (both breath and AA) collected by ReCIVA, likely due to uncorrected and fluctuating flow rates applied by this device. Finally, the analysis of all data also including data obtained by explorative analysis of the unique lung cancer (LC) breath sample showed that a clean air supply might determine a further confounding factor in breath analysis considering that lung wash-out is species-dependent.


Subject(s)
Breath Tests/methods , Adult , Breath Tests/instrumentation , Data Analysis , Female , Gas Chromatography-Mass Spectrometry , Humans , Male , Middle Aged , Reproducibility of Results , Research Design , Specimen Handling , Volatile Organic Compounds/analysis , Young Adult
11.
BMJ Open ; 10(9): e039338, 2020 09 24.
Article in English | MEDLINE | ID: mdl-32973066

ABSTRACT

OBJECTIVES: A number of studies have shown that the airborne transmission route could spread some viruses over a distance of 2 meters from an infected person. An epidemic model based only on respiratory droplets and close contact could not fully explain the regional differences in the spread of COVID-19 in Italy. On March 16th 2020, we presented a position paper proposing a research hypothesis concerning the association between higher mortality rates due to COVID-19 observed in Northern Italy and average concentrations of PM10 exceeding a daily limit of 50 µg/m3. METHODS: To monitor the spreading of COVID-19 in Italy from February 24th to March 13th (the date of the Italian lockdown), official daily data for PM10 levels were collected from all Italian provinces between February 9th and February 29th, taking into account the maximum lag period (14 days) between the infection and diagnosis. In addition to the number of exceedances of the daily limit value of PM10, we also considered population data and daily travelling information for each province. RESULTS: Exceedance of the daily limit value of PM10 appears to be a significant predictor of infection in univariate analyses (p<0.001). Less polluted provinces had a median of 0.03 infections over 1000 residents, while the most polluted provinces showed a median of 0.26 cases. Thirty-nine out of 41 Northern Italian provinces resulted in the category with the highest PM10 levels, while 62 out of 66 Southern provinces presented low PM10 concentrations (p<0.001). In Milan, the average growth rate before the lockdown was significantly higher than in Rome (0.34 vs 0.27 per day, with a doubling time of 2.0 days vs 2.6, respectively), thus suggesting a basic reproductive number R0>6.0, comparable with the highest values estimated for China. CONCLUSION: A significant association has been found between the geographical distribution of daily PM10 exceedances and the initial spreading of COVID-19 in the 110 Italian provinces.


Subject(s)
Air Pollution , Betacoronavirus/isolation & purification , Coronavirus Infections , Disease Transmission, Infectious , Pandemics , Particulate Matter/analysis , Pneumonia, Viral , Air Pollution/analysis , Air Pollution/statistics & numerical data , COVID-19 , Coronavirus Infections/epidemiology , Coronavirus Infections/prevention & control , Coronavirus Infections/transmission , Correlation of Data , Disease Transmission, Infectious/prevention & control , Disease Transmission, Infectious/statistics & numerical data , Humans , Italy/epidemiology , Outcome Assessment, Health Care , Pandemics/prevention & control , Pneumonia, Viral/epidemiology , Pneumonia, Viral/prevention & control , Pneumonia, Viral/transmission , Public Health/methods , Public Health/statistics & numerical data , Risk Assessment/methods , SARS-CoV-2
12.
Article in English | MEDLINE | ID: mdl-32635676

ABSTRACT

The present study was aimed at determining airborne concentrations of PAHs, Nitro-/Oxy-PAHs and elements in industrial and urban areas of Taranto, a site of environmental risk in Southern Italy, after the issue of strategic measures for air pollution mitigation and control by the Italian Environment Ministry in 2012. A PM2.5 sampling campaign was carried out from 9 to 28 December 2014 at eight receptor sites, two placed in the urban settlement and five included in the high spatial resolution fence monitoring network of the biggest European steel plant. The integration of collected data with meteorological parameters and source apportionment analysis by Positive Matrix Factorization and bivariate polar plots allowed to discriminate among emission sources and estimate their contributions. Evidence on the effect of distinct processes (homogenization, sintering) occurring inside the steel plant on airborne concentrations of PAHs and selected elements was provided. The impact of emissions from the steel plant "core" on the surrounding area was observed at receptor sites downwind to it. Moreover, the extent of the effectiveness of mitigation measures, partially applied at the moment of study's beginning, was demonstrated by mean and peak pollutant concentrations at all receptor sites up to one order of magnitude lower than those documented prior to 2012.


Subject(s)
Air Pollutants , Air Pollution , Environmental Monitoring , Particulate Matter , Polycyclic Aromatic Hydrocarbons , Air Pollutants/analysis , Cities , Italy , Particulate Matter/analysis , Vehicle Emissions
13.
Environ Res ; 188: 109754, 2020 Sep.
Article in English | MEDLINE | ID: mdl-32526492

ABSTRACT

BACKGROUND: The burden of COVID-19 was extremely severe in Northern Italy, an area characterized by high concentrations of particulate matter (PM), which is known to negatively affect human health. Consistently with evidence already available for other viruses, we initially hypothesized the possibility of SARS-CoV-2 presence on PM, and we performed a first experiment specifically aimed at confirming or excluding this research hyphotesys. METHODS: We have collected 34 PM10 samples in Bergamo area (the epicenter of the Italian COVID-19 epidemic) by using two air samplers over a continuous 3-weeks period. Filters were properly stored and underwent RNA extraction and amplification according to WHO protocols in two parallel blind analyses performed by two different authorized laboratories. Up to three highly specific molecular marker genes (E, N, and RdRP) were used to test the presence of SARS-CoV-2 RNA on particulate matter. RESULTS: The first test showed positive results for gene E in 15 out of 16 samples, simultaneously displaying positivity also for RdRP gene in 4 samples. The second blind test got 5 additional positive results for at least one of the three marker genes. Overall, we tested 34 RNA extractions for the E, N and RdRP genes, reporting 20 positive results for at least one of the three marker genes, with positivity separately confirmed for all the three markers. Control tests to exclude false positivities were successfully accomplished. CONCLUSION: This is the first evidence that SARS-CoV-2 RNA can be present on PM, thus suggesting a possible use as indicator of epidemic recurrence.


Subject(s)
Betacoronavirus , Coronavirus Infections , Pandemics , Pneumonia, Viral , Betacoronavirus/genetics , COVID-19 , Humans , Italy , Particulate Matter , RNA, Viral/genetics , SARS-CoV-2
14.
Cancers (Basel) ; 12(5)2020 May 16.
Article in English | MEDLINE | ID: mdl-32429446

ABSTRACT

Malignant pleural mesothelioma (MPM) is a rare neoplasm, mainly caused by asbestos exposure, with a high mortality rate. The management of patients with MPM is controversial due to a long latency period between exposure and diagnosis and because of non-specific symptoms generally appearing at advanced stage of the disease. Breath analysis, aimed at the identification of diagnostic Volatile Organic Compounds (VOCs) pattern in exhaled breath, is believed to improve early detection of MPM. Therefore, in this study, breath samples from 14 MPM patients and 20 healthy controls (HC) were collected and analyzed by Thermal Desorption-Gas Chromatography-Mass Spectrometry (TD-GC/MS). Nonparametric test allowed to identify the most weighting variables to discriminate between MPM and HC breath samples and multivariate statistics were applied. Considering that MPM is an aggressive neoplasm leading to a late diagnosis and thus the recruitment of patients is very difficult, a promising data mining approach was developed and validated in order to discriminate between MPM patients and healthy controls, even if no large population data are available. Three different machine learning algorithms were applied to perform the classification task with a leave-one-out cross-validation approach, leading to remarkable results (Area Under Curve AUC = 93%). Ten VOCs, such as ketones, alkanes and methylate derivates, as well as hydrocarbons, were able to discriminate between MPM patients and healthy controls and for each compound which resulted diagnostic for MPM, the metabolic pathway was studied in order to identify the link between VOC and the neoplasm. Moreover, five breath samples from asymptomatic asbestos-exposed persons (AEx) were exploratively analyzed, processed and tested by the validated statistical method as blinded samples in order to evaluate the performance for the early recognition of patients affected by MPM among asbestos-exposed persons. Good agreement was found between the information obtained by gold-standard diagnostic methods such as computed tomography CT and model output.

15.
Article in English | MEDLINE | ID: mdl-32344853

ABSTRACT

A number of nations were forced to declare a total shutdown due to COVID-19 infection, as extreme measure to cope with dramatic impact of the pandemic, with remarkable consequences both in terms of negative health outcomes and economic loses. However, in many countries a "Phase-2" is approaching and many activities will re-open soon, although with some differences depending on the severity of the outbreak experienced and SARS-COV-2 estimated diffusion in the general population. At the present, possible relapses of the epidemic cannot be excluded until effective vaccines or immunoprophylaxis with human recombinant antibodies will be properly set up and commercialized. COVD-19-related quarantines have triggered serious social challenges, so that decision makers are concerned about the risk of wasting all the sacrifices imposed to the people in these months of quarantine. The availability of possible early predictive indicators of future epidemic relapses would be very useful for public health purposes, and could potentially prevent the suspension of entire national economic systems. On 16 March, a Position Paper launched by the Italian Society of Environmental Medicine (SIMA) hypothesized for the first time a possible link between the dramatic impact of COVID-19 outbreak in Northern Italy and the high concentrations of particulate matter (PM10 and PM2.5) that characterize this area, along with its well-known specific climatic conditions. Thereafter, a survey carried out in the U.S. by the Harvard School of Public Health suggested a strong association between increases in particulate matter concentration and mortality rates due to COVID-19. The presence of SARS-COV-2 RNA on the particulate matter of Bergamo, which is not far from Milan and represents the epicenter of the Italian epidemic, seems to confirm (at least in case of atmospheric stability and high PM concentrations, as it usually occurs in Northern Italy) that the virus can create clusters with the particles and be carried and detected on PM10. Although no assumptions can be made concerning the link between this first experimental finding and COVID-19 outbreak progression or severity, the presence of SARS-COV-2 RNA on PM10 of outdoor air samples in any city of the world could represent a potential early indicator of COVID-19 diffusion. Searching for the viral genome on particulate matter could therefore be explored among the possible strategies for adopting all the necessary preventive measures before future epidemics start.


Subject(s)
Coronavirus Infections/epidemiology , Coronavirus , Pandemics , Particulate Matter , Pneumonia, Viral/epidemiology , Aerosols , Betacoronavirus , COVID-19 , Disease Outbreaks , Humans , Italy/epidemiology , Public Health , Quarantine , Recurrence , SARS-CoV-2
16.
Article in English | MEDLINE | ID: mdl-32340347

ABSTRACT

The COVID-19 pandemic caused the shutdown of entire nations all over the world. In addition to mobility restrictions of people, the World Health Organization and the Governments have prescribed maintaining an inter-personal distance of 1.5 or 2 m (about 6 feet) from each other in order to minimize the risk of contagion through the droplets that we usually disseminate around us from nose and mouth. However, recently published studies support the hypothesis of virus transmission over a distance of 2 m from an infected person. Researchers have proved the higher aerosol and surface stability of SARS-COV-2 as compared with SARS-COV-1 (with the virus remaining viable and infectious in aerosol for hours) and that airborne transmission of SARS-CoV can occur besides close-distance contacts. Indeed, there is reasonable evidence about the possibility of SARS-COV-2 airborne transmission due to its persistence into aerosol droplets in a viable and infectious form. Based on the available knowledge and epidemiological observations, it is plausible that small particles containing the virus may diffuse in indoor environments covering distances up to 10 m from the emission sources, thus representing a kind of aerosol transmission. On-field studies carried out inside Wuhan Hospitals showed the presence of SARS-COV-2 RNA in air samples collected in the hospitals and also in the surroundings, leading to the conclusion that the airborne route has to be considered an important pathway for viral diffusion. Similar findings are reported in analyses concerning air samples collected at the Nebraska University Hospital. On March 16th, we have released a Position Paper emphasizing the airborne route as a possible additional factor for interpreting the anomalous COVID-19 outbreaks in northern Italy, ranked as one of the most polluted areas in Europe and characterized by high particulate matter (PM) concentrations. The available information on the SARS-COV-2 spreading supports the hypothesis of airborne diffusion of infected droplets from person to person at a distance greater than two meters (6 feet). The inter-personal distance of 2 m can be reasonably considered as an effective protection only if everybody wears face masks in daily life activities.


Subject(s)
Severe acute respiratory syndrome-related coronavirus , Aerosols , Betacoronavirus , COVID-19 , Coronavirus Infections , Europe , Italy , Nebraska , Pandemics , Pneumonia, Viral , SARS-CoV-2
17.
Sensors (Basel) ; 20(7)2020 Mar 29.
Article in English | MEDLINE | ID: mdl-32235302

ABSTRACT

Currently people are aware of the risk related to pollution exposure. Thus odor annoyances are considered a warning about the possible presence of toxic volatile compounds. Malodor often generates immediate alarm among citizens, and electronic noses are convenient instruments to detect mixture of odorant compounds with high monitoring frequency. In this paper we present a study on pattern recognition on ambient air composition in proximity of a gas and oil pretreatment plant by elaboration of data from an electronic nose implementing 10 metal-oxide-semiconductor (MOS) sensors and positioned outdoor continuously during three months. A total of 80,017 e-nose vectors have been elaborated applying the self-organizing map (SOM) algorithm and then k-means clustering on SOM outputs on the whole data set evidencing an anomalous data cluster. Retaining data characterized by dynamic responses of the multisensory system, a SOM with 264 recurrent sensor responses to air mixture sampled at the site and four main air type profiles (clusters) have been identified. One of this sensor profiles has been related to the odor fugitive emissions of the plant, by using ancillary data from a total volatile organic compound (VOC) detector and wind speed and direction data. The overall and daily cluster frequencies have been evaluated, allowing us to identify the daily duration of presence at the monitoring site of air related to industrial emissions. The refined model allowed us to confirm the anomaly detection of the sensor responses.


Subject(s)
Electronic Nose , Environmental Monitoring , Odorants/analysis , Volatile Organic Compounds/isolation & purification , Air Pollutants/isolation & purification , Air Pollutants/toxicity , Algorithms , Environmental Exposure , Humans , Particulate Matter/isolation & purification , Particulate Matter/toxicity , Principal Component Analysis , Volatile Organic Compounds/toxicity
18.
Toxics ; 7(4)2019 Nov 25.
Article in English | MEDLINE | ID: mdl-31775282

ABSTRACT

The present study aims to evaluate the impact of e-cig second-hand aerosol on indoor air quality in terms of ultrafine particles (UFPs) and potential inhalation exposure levels of passive bystanders. E-cig second-hand aerosol characteristics in terms of UFPs number concentration and size distribution exhaled by two volunteers vaping 15 different e-liquids inside a 49 m3 room and comparison with tobacco smoke are discussed. High temporal resolution measurements were performed under natural ventilation conditions to simulate a realistic exposure scenario. Results showed a systematic increase in UFPs number concentration (part cm-3) related to a 20-min vaping session (from 6.56 × 103 to 4.01 × 104 part cm-3), although this was one up to two order of magnitude lower than that produced by one tobacco cigarette consumption (from 1.12 × 105 to 1.46 × 105 part cm-3). E-cig second-hand aerosol size distribution exhibits a bimodal behavior with modes at 10.8 and 29.4 nm in contrast with the unimodal typical size distribution of tobacco smoke with peak mode at 100 nm. In the size range 6-26 nm, particles concentration in e-cig second-hand aerosol were from 2- (Dp = 25.5 nm) to 3800-fold (Dp = 9.31 nm) higher than in tobacco smoke highlighting that particles exhaled by users and potentially inhaled by bystanders are nano-sized with high penetration capacity into human airways.

19.
Cancers (Basel) ; 11(6)2019 Jun 14.
Article in English | MEDLINE | ID: mdl-31207975

ABSTRACT

Malignant pleural mesothelioma (MPM) is a rare neoplasm related to asbestos exposure and with high mortality rate. The management of patients with MPM is complex and controversial, particularly with regard to early diagnosis. In the last few years, breath analysis has been greatly implemented with this aim. In this review the strengths of breath analysis and preliminary results in searching breath biomarkers of MPM are highlighted and discussed, respectively. Through a systematic electronic literature search, collecting papers published from 2000 until December 2018, fifteen relevant scientific papers were selected. All papers considered were prospective, comparative, observational case-control studies although every single one pilot and based on a relatively small number of samples. The identification of diagnostic VOCs pattern, through breath sample characterization and the statistical data treatment, allows to obtain a strategic information for clinical diagnostics. To date the collected data provide just preliminary information and, despite the promising results and diagnostic accuracy, conclusions cannot be generalized due to the limited number of individuals included in each cohort study. Furthermore none of studies was externally validated, although validation process is a necessary step towards clinical implementation. Breathomics-based biomarker approach should be further explored to confirm and validate preliminary findings and to evaluate its potential role in monitoring the therapeutic response.

20.
Epidemiol Prev ; 42(1): 15-19, 2018.
Article in Italian | MEDLINE | ID: mdl-29506357

ABSTRACT

In Europe, Health Impact Assessment (HIA) is a consolidated practice aimed at predicting health impacts supporting the predisposition of plans and projects subjected to authorization procedures. In Italy, further developments are needed to harmonize the practice and consolidate methodologies in order to extend the HIA application in different fields. The recent HIA conducted in Val d'Agri (Basilicata) on the impacts of a first crude oil treatment plant represents an opportunity to illustrate its tools, methods and fields of application. In this experience, participation methods in impact assessment have been adapted to the context, emphasizing aspects of ethics, equity and democracy. Environmental and epidemiological studies were included in the HIA Val d'Agri in order to characterize the environment and assess the health status of the resident population. On the basis of the results public health recommendations have been elaborated, shared with the stakeholders and shared with local and regional administrators. The experience in Val d'Agri introduces elements of reflection on the potential of HIA at local level in order to support the public health and the environmental control systems in the area, as well as planning based on preventive environment and HIA.


Subject(s)
Health Impact Assessment , Oil and Gas Industry , Petroleum/toxicity , Community Participation , Data Collection/methods , Environmental Monitoring/methods , Environmental Pollutants/toxicity , Epidemiologic Methods , Guidelines as Topic , Humans , Italy , Mass Screening/methods , Public Health , Stakeholder Participation
SELECTION OF CITATIONS
SEARCH DETAIL
...