Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 7 de 7
Filter
Add more filters










Database
Language
Publication year range
1.
Transplantation ; 2023 Dec 07.
Article in English | MEDLINE | ID: mdl-38057969

ABSTRACT

Dynamic organ preservation is a relatively old technique which has regained significant interest in the last decade. Machine perfusion (MP) techniques are applied in various fields of solid organ transplantation today. The first clinical series of ex situ MP in liver transplantation was presented in 2010. Since then, the number of research and clinical applications has substantially increased. Despite the notable beneficial effect on organ quality and recipient outcome, MP is still not routinely used in liver transplantation. Based on the enormous need to better preserve organs and the subsequent demand to continuously innovate and develop perfusion equipment further, this technology is also beneficial to test and deliver future therapeutic strategies to livers before implantation. This article summarizes the various challenges observed during the current shift from static to dynamic liver preservation in the clinical setting. The different organ perfusion strategies are discussed first, together with ongoing clinical trials and future study design. The current status of research and the impact of costs and regulations is highlighted next. Factors contributing to costs and other required resources for a worldwide successful implementation and reimbursement are presented third. The impact of research on cost-utility and effectivity to guide the tailored decision-making regarding the optimal perfusion strategy is discussed next. Finally, this article provides potential solutions to the challenging field of innovation in healthcare considering the various social and economic factors and the role of clinical, regulatory, and financial stakeholders worldwide.

2.
J Hepatol ; 78(5): 1007-1016, 2023 05.
Article in English | MEDLINE | ID: mdl-36740047

ABSTRACT

BACKGROUND & AIMS: Liver graft utilization rates are a hot topic due to the worldwide organ shortage and the increasing number of transplant candidates on waiting lists. Liver perfusion techniques have been introduced in several countries, and may help to increase the organ supply, as they potentially enable the assessment of livers before use. METHODS: Liver offers were counted from donation after circulatory death (DCD) donors (Maastricht type III) arising during the past decade in eight countries, including Belgium, France, Italy, the Netherlands, Spain, Switzerland, the UK, and the US. Initial type-III DCD liver offers were correlated with accepted, recovered and implanted livers. RESULTS: A total number of 34,269 DCD livers were offered, resulting in 9,780 liver transplants (28.5%). The discard rates were highest in the UK and US, ranging between 70 and 80%. In contrast, much lower DCD liver discard rates, e.g. between 30-40%, were found in Belgium, France, Italy, Spain and Switzerland. In addition, we observed large differences in the use of various machine perfusion techniques, as well as in graft and donor risk factors. For example, the median donor age and functional donor warm ischemia time were highest in Italy, e.g. >40 min, followed by Switzerland, France, and the Netherlands. Importantly, such varying risk profiles of accepted DCD livers between countries did not translate into large differences in 5-year graft survival rates, which ranged between 60-82% in this analysis. CONCLUSIONS: Overall, DCD liver discard rates across the eight countries were high, although this primarily reflects the situation in the Netherlands, the UK and the US. Countries where in situ and ex situ machine perfusion strategies were used routinely had better DCD utilization rates without compromised outcomes. IMPACT AND IMPLICATIONS: A significant number of Maastricht type III DCD livers are discarded across Europe and North America today. The overall utilization rate among eight Western countries is 28.5% but varies significantly between 18.9% and 74.2%. For example, the median DCD-III liver utilization in five countries, e.g. Belgium, France, Italy, Switzerland, and Spain is 65%, in contrast to 24% in the Netherlands, UK and US. Despite this, and despite different rules and strategies for organ acceptance and preservation, 1- and 5-year graft survival rates remain fairly similar among all participating countries. A highly varying experience with modern machine perfusion technology was observed. In situ and ex situ liver perfusion concepts, and application of assessment tools for type-III DCD livers before transplantation, may be a key explanation for the observed differences in DCD-III utilization.


Subject(s)
Cardiovascular System , Liver Transplantation , Tissue and Organ Procurement , Humans , Liver , Tissue Donors , Liver Transplantation/methods , Graft Survival , Organ Preservation/methods , Perfusion/methods
3.
Ann Surg ; 276(4): e223-e230, 2022 10 01.
Article in English | MEDLINE | ID: mdl-35861530

ABSTRACT

OBJECTIVE: This study investigates whether liver grafts donated after circulatory death (DCD) that are declined by the entire Eurotransplant region can be salvaged with abdominal normothermic regional perfusion (aNRP). BACKGROUND: aNRP is increasingly used for DCD liver grafts because it prevents typical complications. However, it is unclear whether aNRP is capable to rescue pretransplant declined liver grafts by providing the opportunity to test function during donation. METHODS: Donor livers from DCD donors, declined by all centers in the Eurotransplant region, were included for this study. The comparator cohort included standard DCD livers and livers donated after brain death, transplanted in the same time period. RESULTS: After the withdrawal of life-sustaining treatment, 28 from the 43 donors had a circulatory death within 2 hours, in which case aNRP was initiated. Of these 28 cases, in 3 cases perfusion problems occurred, 5 grafts were declined based on liver assessment, and 20 liver grafts were transplanted. The main differences during aNRP between the transplanted grafts and the assessed nontransplanted grafts were alanine transaminase levels of 53 U/L (34-68 U/L) versus 367 U/L (318-488 U/L) ( P =0.001) and bile production in 100% versus 50% of the grafts ( P =0.024). The 12-month graft and patient survival were both 95%, similar to the comparator cohort. The incidence of ischemic cholangiopathy was 11%, which was lower than in the standard DCD cohort (18%). CONCLUSION: aNRP can safely select and thus is able to rescue DCD liver grafts that were deemed unsuitable for transplantation, while preventing primary nonfunction and minimizing ischemic cholangiopathy.


Subject(s)
Liver Transplantation , Tissue and Organ Procurement , Graft Survival , Humans , Liver/surgery , Organ Preservation , Perfusion , Tissue Donors
4.
Hepatology ; 75(2): 497-498, 2022 02.
Article in English | MEDLINE | ID: mdl-34624135
6.
Sci Rep ; 11(1): 23444, 2021 12 06.
Article in English | MEDLINE | ID: mdl-34873187

ABSTRACT

No single reliable parameter exists to assess liver graft function of extended criteria donors during ex-vivo normothermic machine perfusion (NMP). The liver maximum capacity (LiMAx) test is a clinically validated cytochromal breath test, measuring liver function based on 13CO2 production. As an innovative concept, we aimed to integrate the LiMAx breath test with NMP to assess organ function. Eleven human livers were perfused using NMP. After one hour of stabilization, LiMAx testing was performed. Injury markers (ALT, AST, miR-122, FMN, and Suzuki-score) and lactate clearance were measured and related to LiMAx values. LiMAx values ranged between 111 and 1838 µg/kg/h, and performing consecutive LiMAx tests during longer NMP was feasible. No correlation was found between LiMAx value and miR-122 and FMN levels in the perfusate. However, a significant inverse correlation was found between LiMAx value and histological injury (Suzuki-score, R = - 0.874, P < 0.001), AST (R = - 0.812, P = 0.004) and ALT (R = - 0.687, P = 0.028). Furthermore, a significant correlation was found with lactate clearance (R = 0.683, P = 0.043). We demonstrate, as proof of principle, that liver function during NMP can be quantified using the LiMAx test, illustrating a positive correlation with traditional injury markers. This new breath-test application separates livers with adequate cytochromal liver function from inadequate ones and may support decision-making in the safe utilization of extended criteria donor grafts.


Subject(s)
Cytochrome P-450 CYP1A2/genetics , Liver Transplantation/methods , Liver/physiology , Organ Preservation/instrumentation , Perfusion/instrumentation , Adult , Aged , Cold Ischemia , Graft Survival , Humans , Lactic Acid/metabolism , Liver/surgery , Liver Diseases/pathology , Living Donors , Middle Aged , Probability , Proof of Concept Study , Reperfusion Injury
SELECTION OF CITATIONS
SEARCH DETAIL
...