ABSTRACT

A three-dimensional proton treatment planning system called PROXELPLAN has been used at the National Accelerator Centre (NAC) since October 1994. This system is entirely based on the VOXELPLAN planning system, developed at the Deutches Krebsforschungszentrum (DKFZ), Heidelberg, Germany. The VOXELPLAN system provides the treatment planning infrastructure while the proton dose distributions are calculated using a software module that was initially developed at the Royal Marsden Hospital, UK. The proton module has been extensively modified and refined. It uses a rayline-tracing algorithm which is suitable for planning current treatments but is not sufficiently dynamic to accommodate the use of compensators. A sophisticated pencil beam algorithm is currently under development.


Subject(s)
Proton Therapy , Radiotherapy Planning, Computer-Assisted , Algorithms , Humans , Phantoms, Imaging , Tomography, X-Ray Computed , Water
2.
Strahlenther Onkol ; 175 Suppl 2: 30-2, 1999 Jun.
Article in English | MEDLINE | ID: mdl-10394392

ABSTRACT

The 200 MeV cyclotron facility at the National Accelerator Centre has been operational since 1987. Between September 1988 and December 1997 a total of 973 patients (26,916 fields) had been treated on the 66 MeV p+Be isocentric neutron therapy system. Patients are currently being treated according to several protocols, including tumors of the head and neck, salivary gland and breast and soft tissue sarcomas, uterine sarcomas and paranasal sinuses. A multiblade post-collimator trimmer has recently being installed. This device provides improved neutron beam shaping capability. Between September 1993 and December 1997 a total of 243 patients (4008 fields) had been treated (mainly intracranial stereotactic irradiations) on the fixed horizontal 200 MeV proton therapy facility. The facility incorporates an innovative automatic patient positioning system. Two new fixed beam lines for proton therapy are presently being designed (horizontal and 30 degrees to the vertical) for an existing unused treatment vault. Spot scanning systems will be developed for both beam lines.


Subject(s)
Head and Neck Neoplasms/radiotherapy , Neoplasms/radiotherapy , Particle Accelerators , Radiotherapy Planning, Computer-Assisted , Humans , Neutrons/therapeutic use , Phantoms, Imaging , Proton Therapy , South Africa
SELECTION OF CITATIONS
SEARCH DETAIL
...