Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 5 de 5
Filter
Add more filters










Database
Language
Publication year range
1.
Ophthalmic Surg Lasers Imaging Retina ; 48(4): 358-363, 2017 Apr 01.
Article in English | MEDLINE | ID: mdl-28419404

ABSTRACT

Optic disc pit is a rare congenital anomaly of the optic nerve. Retinal detachment is a common complication with poor outcomes. Many surgical alternatives have been described for the treatment of this condition, producing variable results. Herein, the authors describe four cases of optic disc pit-associated macular detachment managed with pars plana vitrectomy, fluid-air exchange, drainage of subretinal fluid through the optic disc pit, temporal peripapillary laser, and application of Evicel fibrin sealant (human) (Ethicon, Bridgewater, NJ) over the optic disc head. Case 1 showed stable visual acuity and improvement of subretinal fluid. Cases 2 and 3 showed visual acuity and subretinal fluid improvements. At the 1-week follow-up visit, Case 4 showed almost total subretinal fluid absorption. The sealant invariably disappeared between 1 and 2 weeks and was tolerated by all patients. This case series suggests that Evicel fibrin sealant may be considered as an adjunctive option in the surgical treatment of optic disc pit-associated maculopathy. [Ophthalmic Surg Lasers Imaging Retina. 2017;48:358-363.].


Subject(s)
Eye Abnormalities/complications , Fibrin Tissue Adhesive/therapeutic use , Laser Coagulation/methods , Optic Disk/abnormalities , Retinal Detachment/surgery , Visual Acuity , Adult , Eye Abnormalities/diagnosis , Female , Humans , Male , Retinal Detachment/diagnosis , Retinal Detachment/etiology , Tomography, Optical Coherence , Vitrectomy/methods , Young Adult
2.
Can J Ophthalmol ; 52(1): 125-136, 2017 Feb.
Article in English | MEDLINE | ID: mdl-28237138

ABSTRACT

Optical coherence tomography angiography (OCTA) is a novel imaging modality that incorporates blood motion contrast to create angiograms of the retinal vasculature in a noninvasive manner, without the use of dye. It is a safe procedure and can be repeated as frequently as desired. The use of OCTA for delineation of choroidal neovascular membranes, for the study of microvascular abnormalities in diabetic patients, to assess nonperfused areas in retinal occlusions and vascular changes in macular telangiectasia are some of the potential OCTA applications. However, it is not free of drawbacks. Major limitations include the small field of view and its great sensitivity to movement. As a result, it is prone to motion artifacts, leading to poor-quality images. The scope of the body literature regarding this new modality rapidly increases as we learn how to better use this technology. Our objective is to point overall aspects of OCTA, including its limitations and review some of its initial reports on chorioretinal diseases.


Subject(s)
Artifacts , Choroid Diseases/diagnosis , Choroid/diagnostic imaging , Fluorescein Angiography/methods , Retinal Diseases/diagnosis , Retinal Vessels/diagnostic imaging , Tomography, Optical Coherence/methods , Fundus Oculi , Humans
3.
Article in English | MEDLINE | ID: mdl-27980854

ABSTRACT

There have been many advances in vitreoretinal surgery since Machemer introduced the concept of pars plana vitrectomy, in 1971. Of particular interest are the changes in the vitrectomy cutters, their fluidics interaction, the wide-angle viewing systems and the evolution of endoillumination through the past decade and notably in the last few years. The indications of 27-gauge surgery have expanded, including more complex cases. Cut rates of up to 16,000 cuts per minute are already available. New probe designs and pump technology have allowed duty cycle performances of near 100% and improved flow control. The smaller vitrectomy diameter can be positioned between narrow spaces, allowing membrane dissection and serving as a multifunctional instrument. Enhanced endoillumination safety can be achieved by changing the light source, adding light filters, increasing the working distance and understanding the potential interactions between light and vital dyes commonly used to stain the retina. Wide-angle viewing systems (contact, non-contact or a combination of both) provide a panoramic view of the retina. Non-contact systems are assistant-independent, while contact systems may be associated with better image resolution. This review will cover some current aspects on vitrectomy procedures, mainly assessing vitrectomy cutters, as well as the importance of endoillumination and the use of wide-angle viewing systems.

4.
Ophthalmic Surg Lasers Imaging Retina ; 47(9): 848-61, 2016 09 01.
Article in English | MEDLINE | ID: mdl-27631482

ABSTRACT

Fluorescein angiography (FA) and indocyanine green angiography (ICGA) have been the gold standard for the evaluation of retinal and choroidal vasculature in the last three decades and have revolutionized the diagnosis of retinal and choroidal vascular diseases. The advantage of these imaging modalities lies in their ability to document retinal and choroidal vasculature through the dynamic assessment of contrast transit over time in the intravascular and extravascular spaces. However, disadvantages include the absence of depth resolution, blurring of details by contrast leakage, and the inability to selectively evaluate different levels of the retinal and choroidal microvasculature. In addition, these angiographic methods require intravenous dye, which may cause adverse reactions such as nausea, vomiting, and rarely, anaphylaxis. Optical coherence tomography angiography (OCTA) is a noninvasive imaging technique that, in contrast to dye-based angiography, is faster and depth-resolved, allowing in some cases for more precise evaluation of the vascular plexuses of the retina and choroid. The method has been demonstrated in the assessment of various vascular diseases such as venous occlusions, diabetic retinopathy, macular neovascularization, and others. Limitations of this imaging modality include a small registered field of view and the inability to visualize leakage and dye transit over time. It is also subject to a variety of artifacts, including those generated by blinking and eye movement during image acquisition. However, more than an alternative for FA and ICGA, OCTA is bringing new insights to our understanding of retinal and choroidal vascular structure and is changing fundamental paradigms in the clinical management of pathologic conditions. [Ophthalmic Surg Lasers Imaging Retina. 2016;47:848-861.].


Subject(s)
Choroid Diseases/diagnosis , Choroid/pathology , Fluorescein Angiography/methods , Retina/pathology , Retinal Diseases/diagnosis , Retinal Vessels/pathology , Tomography, Optical Coherence/methods , Artifacts , Fundus Oculi , Humans , Reproducibility of Results
5.
Case Rep Ophthalmol Med ; 2016: 5756970, 2016.
Article in English | MEDLINE | ID: mdl-27418990

ABSTRACT

Central retinal vein occlusion (CRVO) is one of the most common retinal vascular disorders. Intense exercise associated CRVO have been described in otherwise healthy young patients. We describe a case of a young male ultramarathoner who presented with a CRVO, presumably associated with dehydration, making part of a marathon runner's retinopathy. Resolution of macular edema and subretinal fluid, with visual acuity improvement, was observed after 3 monthly injections of ranibizumab. Our case suggests that dehydration could be involved in the mechanism of CRVO in healthy young patients and ranibizumab may be an effective treatment option for marathon runner's retinopathy.

SELECTION OF CITATIONS
SEARCH DETAIL
...