Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 1 de 1
Filter
Add more filters










Database
Language
Publication year range
1.
EuroIntervention ; 5(3): 355-62, 2009 Aug.
Article in English | MEDLINE | ID: mdl-19736161

ABSTRACT

AIMS: The aim of this study was to investigate the angiographic and intravascular ultrasound (IVUS) findings of the Endeavor zotarolimus-eluting stent (ZES) in patients from a "real-world" clinical practice. METHODS AND RESULTS: From January to March 2006, 100 patients undergoing routine or emergency percutaneous intervention were prospectively enrolled at one institution. Overall, 39% of the patients were diabetics and 80.8% of lesions were type B2/C. A total of 140 lesions were successfully treated with 174 ZES, and procedural success was 98%. Mean vessel diameter was 2.69 mm and mean lesion length was 16.0 mm; at 6-month angiographic follow-up (completed in 96%), in-stent late lumen loss was 0.66 mm, and in-segment restenosis was 8.2%. Angiographic restenosis was increased among diabetics (15.5 vs. 2.6%, p=0.009), and diabetes was the only significant predictor of angiographic restenosis (OR=15.27 [95%CI 2.45-95.04], p=0.003). By IVUS (performed in 88% at 6-month), % volume obstruction was 14.4+/-13.4%, and there was no late acquired incomplete stent apposition (ISA). At 1-year, overall MACE rate was 6%, including 5 TLRs (4% of patients), with no occurrence of stent thrombosis. CONCLUSIONS: In this prospective "real-world" experience, the ZES demonstrated favourable angiographic and IVUS results in complex patients, with overall in-stent late lumen loss of 0.66 mm, and absence of late acquired ISA. At 1-year, there were no safety concerns including absence of death and stent thrombosis.


Subject(s)
Angioplasty, Balloon, Coronary/instrumentation , Cardiovascular Agents/administration & dosage , Coronary Angiography , Coronary Artery Disease/therapy , Coronary Restenosis/diagnosis , Drug-Eluting Stents , Sirolimus/analogs & derivatives , Ultrasonography, Interventional , Aged , Angioplasty, Balloon, Coronary/adverse effects , Angioplasty, Balloon, Coronary/mortality , Coronary Artery Disease/diagnosis , Coronary Artery Disease/mortality , Coronary Restenosis/etiology , Coronary Restenosis/mortality , Coronary Restenosis/prevention & control , Female , Humans , Kaplan-Meier Estimate , Male , Middle Aged , Prospective Studies , Prosthesis Design , Registries , Risk Assessment , Risk Factors , Sirolimus/administration & dosage , Thrombosis/etiology , Thrombosis/prevention & control , Time Factors , Treatment Outcome
SELECTION OF CITATIONS
SEARCH DETAIL
...