Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 20 de 49
Filter
1.
Antibiotics (Basel) ; 12(8)2023 Jul 31.
Article in English | MEDLINE | ID: mdl-37627683

ABSTRACT

INTRODUCTION: Not enough data exist to inform the optimal duration and type of antimicrobial therapy against GN infections in critically ill patients. METHODS: Narrative review based on a literature search through PubMed and Cochrane using the following keywords: "multi-drug resistant (MDR)", "extensively drug resistant (XDR)", "pan-drug-resistant (PDR)", "difficult-to-treat (DTR) Gram-negative infection," "antibiotic duration therapy", "antibiotic combination therapy" "antibiotic monotherapy" "Gram-negative bacteremia", "Gram-negative pneumonia", and "Gram-negative intra-abdominal infection". RESULTS: Current literature data suggest adopting longer (≥10-14 days) courses of synergistic combination therapy due to the high global prevalence of ESBL-producing (45-50%), MDR (35%), XDR (15-20%), PDR (5.9-6.2%), and carbapenemases (CP)/metallo-ß-lactamases (MBL)-producing (12.5-20%) Gram-negative (GN) microorganisms (i.e., Klebsiella pneumoniae, Pseudomonas aeruginosa, and Acinetobacter baumanii). On the other hand, shorter courses (≤5-7 days) of monotherapy should be limited to treating infections caused by GN with higher (≥3 antibiotic classes) antibiotic susceptibility. A general approach should be based on (i) third or further generation cephalosporins ± quinolones/aminoglycosides in the case of MDR-GN; (ii) carbapenems ± fosfomycin/aminoglycosides for extended-spectrum ß-lactamases (ESBLs); and (iii) the association of old drugs with new expanded-spectrum ß-lactamase inhibitors for XDR, PDR, and CP microorganisms. Therapeutic drug monitoring (TDM) in combination with minimum inhibitory concentration (MIC), bactericidal vs. bacteriostatic antibiotics, and the presence of resistance risk predictors (linked to patient, antibiotic, and microorganism) should represent variables affecting the antimicrobial strategies for treating GN infections. CONCLUSIONS: Despite the strategies of therapy described in the results, clinicians must remember that all treatment decisions are dynamic, requiring frequent reassessments depending on both the clinical and microbiological responses of the patient.

2.
J Orthop Traumatol ; 24(1): 32, 2023 Jun 29.
Article in English | MEDLINE | ID: mdl-37386233

ABSTRACT

BACKGROUND: Minimally invasive spine surgery is a field of active and intense research. Image-guided percutaneous pedicle screw (PPS) placement is a valid alternative to the standard free-hand technique, thanks to technological advancements that provide potential improvement in accuracy and safety. Herein, we describe the clinical results of a surgical technique exploiting integration of neuronavigation and intraoperative neurophysiological monitoring (IONM) for minimally invasive PPS. MATERIALS AND METHODS: An intraoperative-computed tomography (CT)-based neuronavigation system was combined with IONM in a three-step technique for PPS. Clinical and radiological data were collected to evaluate the safety and efficacy of the procedure. The accuracy of PPS placement was classified according to the Gertzbein-Robbins scale. RESULTS: A total of 230 screws were placed in 49 patients. Only two screws were misplaced (0.8%); nevertheless, no clinical sign of radiculopathy was experienced by these patients. The majority of the screws (221, 96.1%) were classified as grade A according to Gertzbein-Robbins scale, seven screws were classified as grade B, one screw was classified as grade D, and one last screw was classified as grade E. CONCLUSIONS: The proposed three-step, navigated, percutaneous procedure offers a safe and accurate alternative to traditional techniques for lumbar and sacral pedicle screw placement. Level of Evidence Level 3. Trial registration Not applicable.


Subject(s)
Intraoperative Neurophysiological Monitoring , Sacrum , Humans , Sacrum/diagnostic imaging , Sacrum/surgery , Neuronavigation , Tomography, X-Ray Computed
3.
Front Psychol ; 14: 1070205, 2023.
Article in English | MEDLINE | ID: mdl-37034909

ABSTRACT

Introduction: Pre-operative psychological factors may influence outcome after spine surgery. The identification of patients at risk of persisting disability may be useful for patient selection and possibly to improve treatment outcome. Methods: Patients with neurogenic claudication associated with degenerative lumbar spinal stenosis (DLSS) performed a psychological assessment before lumbar decompression and fusion (LDF) surgery. The following tests were administrated: Visual Analogic Scale; Symptom Checklist-90 (SCL-90-R), Short Form-36 and Oswestry Disability Index (ODI). The primary outcome was ODI score lower than 20. A cross correlation matrix (CCM) was carried out with significant variables after univariate analysis and a linear logistic regression model was calculated considering the most significant variable. Results: 125 patient (61 men and 64 women) were included in the study. Seven parameters of the SCL-90-R scale showed statistical significance at the univariate analysis: obsessivity (p < 0.001), Current Symptom Index (p = 0.001), Global Severity Index (p < 0.001), depression (p < 0.001), positive Symptom Total (p = 0.002), somatization (p = 0.001) and anxiety (p = 0.036). Obsessivity was correlated with other significant parameters, except GSI (Pearson's correlation coefficient = 0.11).The ROC curve for the logistic model considering obsessivity as risk factor, has an area under the curve of 0.75. Conclusion: Pre-operative psychopathological symptoms can predict persistence of disability after LDF for DLSS. Future studies will evaluate the possibility of modifying post operative outcome through targeted treatment for psychological features emerged during pre-operative assessment.

4.
Medicina (Kaunas) ; 59(2)2023 Feb 11.
Article in English | MEDLINE | ID: mdl-36837544

ABSTRACT

BACKGROUND AND OBJECTIVES: The treatment of end-stage ankle osteoarthritis (OA) and associated hindfoot deformities remains a major challenge for orthopedic surgeons. Numerous techniques and surgical approaches have been proposed for tibiotalar (TT) and tibiotalocalcaneal (TTC) arthrodesis, from arthroscopic to open, as well as numerous devices proposed for internal fixation (retrograde intramedullary nails, cannulated screws, and plating systems). The aim of this study was to retrospectively analyze the results, with at least 18 months of follow-up, with SilverbackTM TT/TTC Plating System Paragon28 in a group of 20 patients with severe OA and hindfoot deformities (mainly secondary post-traumatic OA). MATERIALS AND METHODS: The demographic characteristics and past medical history of the patients were collected and analyzed to identify the cause of the pathology. The degree of OA and deformity were quantified based on foot and ankle weight-bearing radiography and CT examination. Pre- and post-operative clinical and functional scores (ROM, VAS, AOFAS, FFI, and SF-36) and radiographic parameters (anterior distal tibial angle, tibiotalar angle, coronal tibiotalar angle, and hindfoot alignment angle) were evaluated. RESULTS: All of the patients showed clinical and radiographic fusion at an average of 14 weeks (range 12-48), with improvement in pain and functional scores, without major surgical complications and/or infections. CONCLUSIONS: Despite the limitations of our study, the results with this new plating system showed good results in terms of bone consolidation, post-operative complications, and improvement of pain and quality of life in patients with severe OA and deformities of the ankle and hindfoot.


Subject(s)
Ankle , Osteoarthritis , Humans , Retrospective Studies , Quality of Life , Ankle Joint , Arthrodesis/methods , Treatment Outcome
5.
Can J Respir Ther ; 58: 155-161, 2022.
Article in English | MEDLINE | ID: mdl-36304694

ABSTRACT

Background: We report the characteristics, timing, and factors related to the decision to perform a tracheostomy in patients with confirmed COVID-19 infection admitted to eight Italian intensive care units (ICUs). Materials and methods: Prospective observational cohort study of patients with COVID-19 disease on mechanical ventilation. Long-term functional impairment (up to 180 days' post-hospital discharge) was assessed using the Karnofsky scale. Kaplan-Meier analysis assessed differences in survival and freedom from tracheostomy in relation to ICU stay. Cox regression model was used to assess which variables impacted on tracheostomy as a categorical outcome. Results: A total of 248 patients were recruited in the eight participating ICUs. Patients undergoing tracheostomy (n = 128) had longer ICU (25 (18-36) vs. 10 (7-16), P = 0.001) and hospital (37 (26.5-50) vs. 19 (8.5-34.5) P = 0.02) stays. ICU and hospital mortality of patients tracheostomized was 34% and 37%, respectively. Cumulative survival Kaplan-Meier analysis documented improved survival rates in patients undergoing tracheostomy (Log-Rank, Mantel-Cox = 4.8, P = 0.028). Median Karnofsky scale values improved over time but were similar between survivors receiving or not receiving tracheostomy. No healthcare worker involved in the tracheostomy procedure developed COVID-19 infection during the study period. Conclusions: Patients with COVID-19 infection who underwent tracheostomy had a better cumulative survival but similar long-term functional outcomes at 30, 60, and 180 days after hospital discharge.

6.
J Orthop Traumatol ; 23(1): 44, 2022 Sep 01.
Article in English | MEDLINE | ID: mdl-36048284

ABSTRACT

BACKGROUND: Percutaneous pedicle screw (PPS) placement is a key step in several minimally invasive spinal surgery (MISS) procedures. Traditional technique for PPS makes use of C-arm fluoroscopy assistance (FA). More recently, newer intraoperative imaging techniques have been developed for PPS, including CT-guided navigation (CTNav). The aim of this study was to compare FA and CTNav techniques for PPS with regard to accuracy, complications, and radiation dosage. MATERIALS AND METHODS: A total of 192 patients with degenerative lumbar spondylolisthesis and canal stenosis who underwent MISS posterior fusion ± interbody fusion through transforaminal approach (TLIF) were retrospectively reviewed. Pedicle screws were placed percutaneously using either standard C-arm fluoroscopy guidance (FA group) or CT navigation (CTNav group). Intraoperative effective dose (ED, mSv) was measured. Screw placement accuracy was assessed postoperatively on a CT scan using Gertzbein and Robbins classification (grades A-E). Oswestry disability index (ODI) and visual analog scale (VAS) scores were compared in both groups before and after surgery. RESULTS: A total of 101 and 91 procedures were performed with FA (FA group) and CTNav approach (CTNav group), respectively. Median age was 61 years in both groups, and the most commonly treated level was L4-L5. Median ED received from patients was 1.504 mSv (0.494-4.406) in FA technique and 21.130 mSv (10.840-30.390) in CTNav approach (p < 0.001). Percentage of grade A and B screws was significantly higher for the CTNav group (96.4% versus 92%, p < 0.001), whereas there were 16 grade E screws in the FA group and 0 grade E screws in the CTNav group (p < 0.001). A total of seven and five complications were reported in the FA and CTNav group, respectively (p = 0.771). CONCLUSIONS: CTNav technique increases accuracy of pedicle screw placement compared with FA technique without affecting operative time. Nevertheless, no significant difference was noted in terms of reoperation rate due to screw malpositioning between CTNav and FA techniques. Radiation exposure of patients was significantly higher with CTNav technique. LEVEL OF EVIDENCE: Level 3.


Subject(s)
Pedicle Screws , Spinal Fusion , Surgery, Computer-Assisted , Fluoroscopy/methods , Humans , Lumbar Vertebrae/diagnostic imaging , Lumbar Vertebrae/surgery , Middle Aged , Retrospective Studies , Spinal Fusion/adverse effects , Surgery, Computer-Assisted/methods , Tomography, X-Ray Computed
7.
Orthop Rev (Pavia) ; 14(2): 33768, 2022.
Article in English | MEDLINE | ID: mdl-35774931

ABSTRACT

Background: Starting in January 2020, the SARS-CoV-2 pandemic caused changes in the nation's health systems. The hospital's reorganization led to a near-total stop of non-urgent, elective surgeries across all specialties, including hip and knee arthroplasty. However, in May 2020, a gradual elective surgery restarting was possible. Considering the risk of COVID-19 infections, the European Knee Associates suggest the need to implement specific protocols for a safe return to orthopaedic elective surgery. Methods: A retrospective analysis regarding all patients who underwent primary knee arthroplasty (TKA) between March 1st and October 1st, 2020 using an institutional database was performed. The study time was divided into 2 periods: Pandemic (from March 2020 to May 2020), Post Pandemic (from June 2020 to October 2020). A specific protocol was designed to safeguard the health of patients and healthcare workers during the SARS-CoV-2 pandemic. Results: A total of 147 patients underwent total knee replacement surgery in the analyzed period. The mean surgical time was 77.6 (+/-18.9). The intraoperative mean blood loss was 54 (+/-28) ml. The mean hospital stay was 3-4 days. Among the treated patients no case of COVID-19 infection was observed. Conclusion: The use of our protocol, developed ad hoc for the management of elective orthopedic patients, allowed the restart of elective orthopedic surgery in a safe and reproducible way with an average increase of 374% on surgical activity between the pandemic and post-pandemic periods without record cases of contagion among the treated patients.

8.
J Pers Med ; 12(6)2022 Jun 17.
Article in English | MEDLINE | ID: mdl-35743770

ABSTRACT

Background: Anterior cervical discectomy and interbody fusion (ACDF) may be performed with different kinds of stand-alone cages. Tantalum and polyetheretherketone (PEEK) are two of the most commonly used materials in this procedure. Few comparisons between different stand-alone implants for ACDF have been reported in the literature. Methods: We performed a comparison between patients who underwent ACDF with either a porous tantalum or a PEEK stand-alone cage, in two spine surgery units for single-level disc herniation. Clinical outcome [Neck Disability Index (NDI), Visual Analog Scale (VAS) for pain, Short Form-36 (SF-36)] and radiological outcome (lordosis, fusion and subsidence) were measured before surgery and at least one year after surgery in both groups. Results: Thirty-eight patients underwent ACDF with a porous tantalum cage, and thirty-one with a PEEK cage. The improvement of NDI and SF-36 was significantly superior in the PEEK group (p = 0.002 and p = 0.049 respectively). Moreover, the variation of the Cobb angle for the cervical spine was significantly higher in the PEEK group (p < 0.001). Conclusions: In a retrospective analysis of two groups of patients with at least one year of follow-up, a stand-alone PEEK cage showed superior clinical results, with improved cervical lordosis, compared to a stand-alone porous tantalum cage. Further studies are needed to confirm these data.

9.
BMC Musculoskelet Disord ; 22(Suppl 2): 1061, 2022 Jan 10.
Article in English | MEDLINE | ID: mdl-35012499

ABSTRACT

BACKGROUND: Short-stem Hip Arthroplasty (SHA) are increasingly implanted in recent years thanks to their potential advantage in preserving metaphyseal bone-stock. Among them, the NANOS® short-stem implant demonstrated satisfactory results to short and mid-term. The purpose of this retrospective study was to evaluate the clinical and radiographic outcome of the Nanos® short stem at a minimum follow-up of 10 years. METHODS: Sixty-seven patients aged 53 ± 20 years were enlisted in the study, for a total of 72 hips. Primary outcomes were survivorship of the implant and clinical outcome measured using the Hip disability and Osteoarthritis Outcome scores (HOOS) and the Short Form Survey (SF12) questionnaire. The secondary outcome was a radiological evaluation calculating the inclination and the anteversion angle of the acetabular cup for each implant and investigating osteolysis, heterotopic ossifications and stem position. RESULTS: We observed a 95.5% stem survivorship. The complication rate was 7.6% and three implants underwent revision because of an aseptic loosening, an infection and a periprosthetic fracture due to trauma. Among 58 patients (63 hips) evaluated in an outpatient visit 10-16 years after surgery, improvement in clinically relevant scores comparing with baseline was observed: HOOS score increased after surgery in all its subcategories (from 32.25 ± 14.07% up to 91.91 ± 9.13%) as well as SF12 which increased by more than 18 percentage points. On clinical assessment, the range of motion (ROM) was restored at follow-up, 1 patient (1.7%) showed a squeaking hip and 2 (3.4%) reported leg-length discrepancy. Neutral stem positioning was achieved in 58 hips and heterotopic ossifications occurred in 10 hips (16%). CONCLUSIONS: The current study reports good clinical and radiological outcomes following NANOS® short-stem hip implant at minimum 10 years-follow-up. Since the high rate of stem survivorship, the low complication rate demonstrated and the overall patient satisfaction, our results suggest NANOS® neck-preserving prostheses should be considered as a valid alternative to standard implants.


Subject(s)
Arthroplasty, Replacement, Hip , Hip Prosthesis , Follow-Up Studies , Humans , Prosthesis Design , Prosthesis Failure , Reoperation , Retrospective Studies , Treatment Outcome
10.
Infection ; 50(1): 139-148, 2022 Feb.
Article in English | MEDLINE | ID: mdl-34260055

ABSTRACT

PURPOSE: To investigate the prevalence, incidence and characteristics of bacterial infections and their impact on outcome in critically ill patients infected with COVID-19. METHODS: We conducted a prospective observational study in eight Italian ICUs from February to May 2020; data were collected through an interactive electronic database. Kaplan-Meier analysis (limit product method) was used to identify the occurrence of infections and risk of acquisition. RESULTS: During the study period 248 patients were recruited in the eight participating ICUs. Ninety (36.3%) patients developed at least one episode of secondary infection. An ICU length of stay between 7 and 14 days was characterized by a higher occurrence of infectious complications, with ventilator-associated pneumonia being the most frequent. At least one course of antibiotic therapy was given to 161 (64.9%) patients. Overall ICU and hospital mortality were 33.9% and 42.9%, respectively. Patients developing bacteremia had a higher risk of ICU mortality [45.9% vs. 31.6%, odds ratio 1.8 (95% CI 0.9-3.7), p = 0.069] and hospital mortality [56.8% vs. 40.3%, odds ratio 1.9 (95% CI 1.1-3.9), p = 0.04]. CONCLUSION: In critically ill patients infected with COVID-19 the incidence of bacterial infections is high and associated with worse outcomes. Regular microbiological surveillance and strict infection control measures are mandated.


Subject(s)
Bacterial Infections , COVID-19 , Bacterial Infections/epidemiology , Critical Illness , Humans , Intensive Care Units , Prospective Studies , SARS-CoV-2
12.
J Orthop Traumatol ; 21(1): 22, 2020 Dec 02.
Article in English | MEDLINE | ID: mdl-33263831

ABSTRACT

BACKGROUND: The purpose of this study was to evaluate (1) the reoperation rates and survivorship for septic and aseptic causes, (2) radiographic outcomes, and (3) clinical outcomes of condylar-constrained knee (CCK) implants used in primary total knee arthroplasty (TKA) with severe coronal deformity and/or intraoperative instability. MATERIALS AND METHODS: A consecutive series of CCK implants in primary TKA was retrospectively evaluated in patients with severe coronal deformities. Forty-nine patients (54 knees) were included with a mean follow-up of 9 years (range 6-12). All patients were treated with a single-design, second-generation CCK implant. The primary diagnosis was osteoarthritis in 36 knees, post-traumatic arthritis in 7 knees, and rheumatoid arthritis in 4 knees. Preoperatively, standing femorotibial alignment was varus in 22 knees and valgus in 20 knees. RESULTS: At a mean follow-up of 9 years, overall survivorship was 93.6%. Two knees (4.3%) required revision for periprosthetic joint infection. One knee (2.1%) required subsequent arthroscopy due to patellar clunk syndrome. At final follow-up, no evidence of loosening or migration of any implant was reported, and the mean Knee Society knee scores improved from 43 to 86 points (p < 0.001). The mean Knee Society function scores improved to 59 points (p < 0.001). The average flexion contracture improved from 7° preoperatively to 2° postoperatively and the average flexion from 98° to 110°. No knees reported varus-valgus instability in flexion or extension. CONCLUSION: CCK implants in primary TKA with major coronal deformities and/or intraoperative instability provide good midterm survivorship, comparable with less constrained implants. In specific cases, CCK implants can be considered a viable option with good clinical and radiographic outcomes. However, a higher degree of constraint should be used cautiously, leaving the first choice to less constrained implants. Level of evidence Therapeutic study, level IV.


Subject(s)
Arthritis/surgery , Arthroplasty, Replacement, Knee , Knee Joint/surgery , Knee Prosthesis , Prosthesis Failure , Reoperation , Adult , Aged , Aged, 80 and over , Arthritis/diagnostic imaging , Arthroplasty, Replacement, Knee/adverse effects , Arthroplasty, Replacement, Knee/methods , Female , Follow-Up Studies , Humans , Joint Instability/diagnostic imaging , Joint Instability/surgery , Knee Joint/diagnostic imaging , Knee Prosthesis/adverse effects , Male , Middle Aged , Prosthesis Design , Range of Motion, Articular , Retrospective Studies , Treatment Outcome
13.
Orthop Rev (Pavia) ; 12(Suppl 1): 8666, 2020 Jun 29.
Article in English | MEDLINE | ID: mdl-32913600

ABSTRACT

Rhizarthrosis is a progressive and disabling pathology affecting the carpometacarpal joint. It's very common in elderly patients and typically affects postmenopausal women. The diagnosis of rhizarthrosis is mainly made by using different physical examination tests and by evaluating the type of pain and it's then confirmed by imaging. Over the last few years increasing attention has been devoted to the assessment of new treatment techniques for rhizarthrosis. In this context intra-articular injection of autologous fat grafting for cartilage regeneration has demonstrated promising results in experimental settings as an alternative to open surgery procedures. The aim of this study was therefore to sum up the evidences available so far on autologous fat grafting as an emerging treatment for patients affected by carpometacarpal rizarthrosis. An electronic literature research was carried out on Pubmed, Google Scholars and Cochrane Library using "fat grafting", "fat graft", "adipose", "fat transfer" and "lipoaspirate" as search terms. Authors believe autologous fat grafting is an interesting technique, that hand surgeon should keep in mind especially in early stages of rhizarthrosis were pain has not been solved with non-surgical treatment.

15.
Acta Biomed ; 90(1-S): 110-115, 2019 01 14.
Article in English | MEDLINE | ID: mdl-30715008

ABSTRACT

BACKGROUND AND AIM: Femoral shaft fracture is a common traumatic musculoskeletal injures in pediatric population. The treatment of diaphyseal femoral fractures depends on age patient and pattern fracture. We present our record about the use of locking plate fixation and their outcomes. METHOD: We conduct a retrospective analysis in 22 patients, surgically treated for 26 diaphyseal femur fracture between 2008 and 2013. The mean age was 13 years. All the patients underwent a clinical and radiological follow-up for two years. We recorded time to weight bearing, time to union, complication (malalignment, dysmetria, infection), time to resumption to sport, plate removal, parents' satisfaction. RESULTS: All the patients had a minimal clinical e radiological follow-up of 24 months. The average fracture healing time was of 7.4 weeks. All the patients had a full hip and knee range of movements. Fifteen patients developed minor malalignment (varovalgus or procurvatum femur) without clinical effects. No cases of infections. The mean time to a full weight bearing was 12 weeks and the return to sportive activity was 24 weeks. Four patients required a plate and screws removal. The average result of parents' satisfaction was 8/10. CONCLUSIONS: Locking plate fixation is to be considered a successful way of treatment for pediatric femur fractures, especially in patients older than 6 years, head-injured or in the treatment of polytrauma. The anatomic and functional outcomes are comparable to those of other fixation techniques for this kind of fracture.


Subject(s)
Bone Plates , Femoral Fractures/surgery , Fracture Fixation, Internal/instrumentation , Adolescent , Child , Female , Fracture Healing , Humans , Male , Recovery of Function , Retrospective Studies , Treatment Outcome , Weight-Bearing
16.
Radiol Med ; 123(8): 593-600, 2018 Aug.
Article in English | MEDLINE | ID: mdl-29637389

ABSTRACT

OBJECTIVE: The study aimed to assess image quality when using dual-energy CT (DECT) to reduce metal artifacts in subjects with knee and hip prostheses. METHODS: Twenty-two knee and 10 hip prostheses were examined in 31 patients using a DECT protocol (tube voltages 100 and 140 kVp). Monoenergetic reconstructions were extrapolated at 64, 69, 88, 105, 110, 120, 140, 170, and 190 kilo-electron volts (keV) and the optimal energy was manually selected. The B60-140 and Fast DE reconstructions were made by CT. The image quality and diagnostic value were subjectively and objectively determined. Double-blind qualitative assessment was performed by two radiologists using a Likert scale. For quantitative analysis, a circular region of interest (ROI) was placed by a third radiologist within the most evident streak artifacts on every image. Another ROI was placed in surrounding tissues without artifacts as a reference. RESULTS: The inter-reader agreement for the qualitative assessment was nearly 100%. The best overall image quality (37.8% rated "excellent") was the Fast DE Siemens reconstruction, followed by B60-140 and Opt KeV (20.5 and 10.2% rated excellent). On the other hand, DECT images at 64, 69 and 88 keV had the worse scores. The number of artifacts was significantly different between monoenergetic images. Nevertheless, because of the high number of pairwise comparisons, no differences were found in the post hoc analysis except for a trend toward statistical significance when comparing the 170 and 64 keV doses. CONCLUSIONS: DECT with specific post-processing may reduce metal artifacts and significantly enhance the image quality and diagnostic value when evaluating metallic implants.


Subject(s)
Artifacts , Hip Prosthesis , Knee Prosthesis , Metals , Radiographic Image Interpretation, Computer-Assisted/methods , Tomography, X-Ray Computed/methods , Aged , Aged, 80 and over , Female , Humans , Male , Middle Aged , Prospective Studies
17.
Acta Biomed ; 90(1-S): 130-135, 2018 12 20.
Article in English | MEDLINE | ID: mdl-30715011

ABSTRACT

BACKGROUND AND AIM OF THE WORK: Since 2006, It has been developed the possibility to introduce a tibia nail through a suprapatellar access. However, the removal of device must be carried out using the classic infrapatellar approach. The aim of this study is to evaluate the clinical scores of a group of patients that removed a tibial nail by infrapatellar approach, previously introduced through a suprapatellar access. METHODS: Seven patients received removal, through infrapatellar access, of tibial nail previously introduced by suprapatellar approach. Despite being VAS <5, patients requested the device to be removed. The variables studied were the distance between the apex of the nail and the tibial plateau (TPD) and between the apex of the nail and the anterior tibia (ATD), oxford knee score (OKS), Kujala score (KJS), Visual Analog Scale (VAS) and SF 36 before surgery and 1 year. A1 year of follow up the Sidky-Buckley questionnaire was administered. The follow-up was 1 year. RESULTS: The mean VAS was 2.8 before surgery and 0.5 at 1 year after surgery, OKS average pre-surgery is 38 (good), while at 1 year it becomes 44 (excellent). The Sidky-Buckley questionnaire showed that all patients would have the intramedullary nail removed again. The widest improvement in all parameters is seen in the two patients with less distance from the tibial plateau. CONCLUSIONS: Although the patients had received initial suprapatellar access and a second infrapatellar for the removal of the device, no complications were reported regarding the use of the two accesses.


Subject(s)
Bone Nails , Device Removal/methods , Fracture Fixation, Intramedullary/methods , Tibial Fractures/surgery , Adult , Female , Fibula/injuries , Fibula/surgery , Fracture Fixation, Intramedullary/instrumentation , Fracture Healing , Fractures, Bone/surgery , Humans , Male , Middle Aged , Patella , Patient Satisfaction , Recovery of Function , Surveys and Questionnaires , Visual Analog Scale
18.
J Appl Biomater Funct Mater ; 15(1): e1-e9, 2017 Jan 26.
Article in English | MEDLINE | ID: mdl-28009420

ABSTRACT

BACKGROUND: Metallic ball heads for total hip replacement (THR) bearings with ceramicized surfaces were introduced in orthopedics during the second half of the 1980s, with the aim of decreasing the wear of polyethylene cups. METHODS: An analysis was made of the literature regarding outcomes for metallic ball heads with ceramicized surfaces now in clinical use (TiN, TiNbN, ZrN, monoclinic ZrO2), as well as carbon coatings (pyrolytic carbon, diamond-like carbon) and silicon nitride as coatings in ball heads for THR bearings. RESULTS: Notwithstanding the diffusion of ceramicized ball heads in THRs, there are few reports about their clinical outcomes in hip arthroplasty. In addition, several clinical studies and some registry data are putting under scrutiny the clinical advantages of ceramicized ball heads over cobalt chrome (CoCr) alloy and ceramic ball heads. CONCLUSIONS: The wear of THR bearings with ceramicized ball heads looks like it depends more on the behavior of the polyethylene cups than on the treatment of the ball head surface. The risk of coating damage and of its consequences has to be taken into account in selecting this type of bearing.


Subject(s)
Arthroplasty, Replacement, Hip/methods , Ceramics , Hip Prosthesis , Arthroplasty, Replacement, Hip/adverse effects
20.
J Arthroplasty ; 31(9 Suppl): 110-4, 2016 09.
Article in English | MEDLINE | ID: mdl-26781387

ABSTRACT

BACKGROUND: The porous tantalum monoblock cup has demonstrated excellent short-term and midterm clinical and radiographic outcomes in primary THA, but longer follow-up is necessary to confirm the durability of these results into the second decade. The purpose of this study is to report the clinical and radiographic outcomes for this monoblock cup with a minimum 15-year follow-up. METHODS: From June 1998 to December 1999, 61 consecutive patients (63 hips) underwent primary THA with a tantalum monoblock acetabular component. All patients were followed clinically and radiographically for a minimum of 15 years. At a mean of 15.6 years (range, 15-16 years) of follow-up, 5 patients had died, and 4 had been lost to follow-up, leaving 52 patients (54 hips) for analysis. The underlying diagnosis that led to the primary THA was primary osteoarthritis in 43 hips, avascular necrosis in 4, developmental hip dysplasia in 3, rheumatoid arthritis in 3 and post-traumatic osteoarthritis in 1. RESULTS: One cup was revised for deep infection; at surgery, the cup showed osseointegration. At a mean follow-up of 15.6 years (range, 15-16 years), the survivorship with cup revision for aseptic loosening as end point was 100%. There was no radiographic evidence of loosening, migration, or gross polyethylene wear at last follow-up. The mean Harris Hip Scores improved from 47 points preoperatively to 94 points. CONCLUSION: The porous tantalum monoblock cup in primary THA demonstrated excellent clinical and radiographic outcomes with no failures because of osteolysis or loosening at a minimum follow-up of 15 years.


Subject(s)
Arthroplasty, Replacement, Hip/instrumentation , Hip Prosthesis/statistics & numerical data , Tantalum , Acetabulum , Aged , Aged, 80 and over , Female , Follow-Up Studies , Hip Dislocation, Congenital/surgery , Humans , Male , Middle Aged , Osteoarthritis, Hip/surgery , Polyethylene , Porosity , Prosthesis Failure , Retrospective Studies
SELECTION OF CITATIONS
SEARCH DETAIL
...