Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 2 de 2
Filter
Add more filters










Database
Language
Publication year range
1.
J Environ Sci Health B ; 53(7): 434-440, 2018.
Article in English | MEDLINE | ID: mdl-29469607

ABSTRACT

On-line in-tube solid phase microextraction (in-tube SPME) coupled to high performance liquid chromatography and tandem mass spectrometry (HPLC-MS/MS) was successfully applied to the determination of selected triazines in water samples. The method based on the employment of a packed column containing graphene oxide (GO) supported on aminopropyl silica (Si) showed that the extraction phase has a high potential for triazines extraction aiming to its physical-chemical properties including ultrahigh specific surface area, good mechanical and thermal stability and high fracture strength. Injection volume and loading time were both investigated and optimized. The method validation using Si-GO to extract and concentrate the analytes showed satisfactory results, good sensitivity, good linearity (0.2-4.0 µg L-1) and low detection limits (1.1-2.9 ng L-1). The high extraction efficiency was determined with enrichment factors ranging from 1.2-2.9 for the lowest level, 1.3-4.9 intermediate level and 1.2-3.0 highest level (n = 3). Although the analytes were not detected in the real samples evaluated, the method has demonstrated to be efficient through its application in the analysis of spiked triazines in ground and mineral water samples.


Subject(s)
Solid Phase Microextraction/instrumentation , Tandem Mass Spectrometry/methods , Triazines/analysis , Water Pollutants, Chemical/analysis , Brazil , Chromatography, High Pressure Liquid/methods , Equipment Design , Graphite/chemistry , Limit of Detection , Oxides/chemistry , Reproducibility of Results , Silicon Dioxide/chemistry , Solid Phase Microextraction/methods
2.
J Environ Sci Health B ; 50(11): 753-9, 2015.
Article in English | MEDLINE | ID: mdl-26357886

ABSTRACT

A method for the identification and quantification of pesticide residues in water, soil, and sediment samples has been developed, validated, and applied for the analysis of real samples. The specificity was determined by the retention time and the confirmation and quantification of analyte ions. Linearity was demonstrated over the concentration range of 20 to 120 µg L(-1), and the correlation coefficients varied between 0.979 and 0.996, depending on the analytes. The recovery rates for all analytes in the studied matrix were between 86% and 112%. The intermediate precision and repeatability were determined at three concentration levels (40, 80, and 120 µg L(-1)), with the relative standard deviation for the intermediate precision between 1% and 5.3% and the repeatability varying between 2% and 13.4% for individual analytes. The limits of detection and quantification for fipronil, fipronil sulfide, fipronil-sulfone, and fipronil-desulfinyl were 6.2, 3.0, 6.6, and 4.0 ng L(-1) and 20.4, 9.0, 21.6, and 13.0 ng L(-1), respectively. The method developed was used in water, soil, and sediment samples containing 2.1 mg L(-1) and 1.2% and 5.3% of carbon, respectively. The recovery of pesticides in the environmental matrices varied from 88.26 to 109.63% for the lowest fortification level (40 and 100 µg kg(-1)), from 91.17 to 110.18% for the intermediate level (80 and 200 µg kg(-1)), and from 89.09 to 109.82% for the highest fortification level (120 and 300 µg kg(-1)). The relative standard deviation for the recovery of pesticides was under 15%.


Subject(s)
Gas Chromatography-Mass Spectrometry/methods , Pyrazoles/analysis , Soil Pollutants/analysis , Water Pollutants, Chemical/analysis , Brazil , Geologic Sediments/analysis , Limit of Detection , Pesticide Residues/analysis , Sensitivity and Specificity , Soil/chemistry , Water/analysis
SELECTION OF CITATIONS
SEARCH DETAIL
...