Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 2 de 2
Filter
Add more filters










Database
Language
Publication year range
1.
J Refract Surg ; 40(6): e407-e419, 2024 May.
Article in English | MEDLINE | ID: mdl-38848051

ABSTRACT

PURPOSE: To assess clinical outcomes after cataract surgery with bilateral implantation of a new bi-aspheric diffractive intraocular lens (IOL). METHODS: Thirty patients underwent bilateral implantation of the Asqelio Trifocal Toric IOL (AST Products, Inc) and were evaluated 3 months postoperatively. Main outcomes included refractive error, photopic monocular and binocular uncorrected and corrected distance (UDVA, CDVA), intermediate (UIVA, CDIVA) at 60 cm, and near (UNVA, CDNVA) at 40 cm visual acuities. Mesopic monocular and binocular CDNVA were also measured. Defocus curves, binocular contrast sensitivity under photopic and mesopic conditions with and without glare and rotational stability were determined. Patients completed Catquest-9SF and visual symptoms questionnaires. RESULTS: Average values of binocular photopic CDVA, CDIVA, and CDNVA, and mesopic CDNVA were -0.04 ± 0.06, 0.02 ± 0.08, 0.02 ± 0.07, and 0.22 ± 0.11 logMAR, respectively. All patients achieved cumulative CDVA ⩾ 20/25, and CDIVA and CDNVA of 20/32 or better. Binocular depth of focus was approximately 3.25 diopters (D). Mean postoperative spherical equivalent was -0.08 ± 0.26 D, with 95% of eyes within ±0.50 D. Mean postoperative refractive cylinder was -0.22 ± 0.27 D, with 91.67% of eyes within 0.50 D or less, respectively. IOL rotation averaged 0.25 ± 0.65 degrees, all eyes having rotation of less than 5 degrees. Contrast sensitivity was within or above normal levels under photopic and mesopic conditions, with or without glare, except for 12 cpd under mesopic conditions with glare. Questionnaire responses indicated 96.67% of patients were satisfied or very satisfied with postoperative vision, and 80.00% to 96.67% reported no difficulty in different daily activities. CONCLUSIONS: The Asqelio Trifocal Toric IOL demonstrated favorable outcomes, providing excellent visual performance at all distances, precise refractive results, and remarkable rotational stability. Patients reported high satisfaction levels and minimal difficulty in daily activities. [J Refract Surg. 2024;40(6):e407-e419.].


Subject(s)
Contrast Sensitivity , Lens Implantation, Intraocular , Multifocal Intraocular Lenses , Patient Satisfaction , Phacoemulsification , Prosthesis Design , Pseudophakia , Refraction, Ocular , Vision, Binocular , Visual Acuity , Humans , Visual Acuity/physiology , Vision, Binocular/physiology , Male , Female , Aged , Refraction, Ocular/physiology , Pseudophakia/physiopathology , Middle Aged , Contrast Sensitivity/physiology , Surveys and Questionnaires , Prospective Studies , Aged, 80 and over , Lenses, Intraocular , Treatment Outcome
2.
Clin Ophthalmol ; 18: 27-40, 2024.
Article in English | MEDLINE | ID: mdl-38192579

ABSTRACT

Purpose: To assess refractive and visual outcomes post-cataract surgery with bilateral implantation of a bi-aspheric diffractive trifocal intraocular lens (IOL). Methods: A total of 24 patients who underwent bilateral implantation with the Asqelio Trifocal IOL TFLIO130C were evaluated at the 6 months postoperative mark. Key outcome measures included refractive error, photopic monocular and binocular uncorrected and corrected distance visual acuity (UDVA, CDVA), uncorrected and corrected intermediate visual acuity (UIVA, CDIVA) at 60 cm, and uncorrected and corrected near visual acuity (UNVA, CDNVA) at 40 cm. Additionally, monocular and binocular CDNVA were assessed under mesopic conditions. Monocular and binocular defocus curves, and binocular contrast sensitivity under photopic and mesopic conditions, with and without glare, were measured. Catquest-9SF and visual symptoms questionnaires were also administered. Results: Postoperative average values of binocular logMAR photopic CDVA, photopic CDIVA, photopic CDNVA and mesopic CDNVA were -0.01±0.06, 0.03±0.09, 0.02±0.05 and 0.19±0.13, respectively. About 100% of patients showed cumulative CDVA and CDNVA ≥20/25, and CDIVA ≥20/32. The average absolute depth-of-focus was about 4.50D. The average postoperative spherical equivalent was 0.05±0.30D and 100% and 93.75% eyes were within ±1.00D and ±0.50D, respectively. Contrast sensitivity was either within or above normal levels under both photopic and mesopic conditions, both with and without glare, except for 12 cpd under mesopic conditions with glare where the mean falls just below the normal range. Questionnaires revealed that 87.5% of patients were either satisfied or very satisfied with their vision after the surgery, and higher percentages for no difficulty in performing different activities, ranging from 70.83% to 95.83%, were reported. Conclusion: This study demonstrates that the bi-aspheric diffractive trifocal IOL yields very good visual performance across distances, fostering high satisfaction levels and minimal difficulties in daily activities.

SELECTION OF CITATIONS
SEARCH DETAIL
...