Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 3 de 3
Filter
Add more filters










Database
Language
Publication year range
1.
Eur Radiol ; 2024 Jan 29.
Article in English | MEDLINE | ID: mdl-38285103

ABSTRACT

BACKGROUND: Intravenous thrombolysis (IVT) before endovascular treatment (EVT) for acute ischemic stroke might induce intracerebral hemorrhages which could negatively affect patient outcomes. Measuring white matter lesions size using deep learning (DL-WML) might help safely guide IVT administration. We aimed to develop, validate, and evaluate a DL-WML volume on CT compared to the Fazekas scale (WML-Faz) as a risk factor and IVT effect modifier in patients receiving EVT directly after IVT. METHODS: We developed a deep-learning model for WML segmentation on CT and validated with internal and external test sets. In a post hoc analysis of the MR CLEAN No-IV trial, we associated DL-WML volume and WML-Faz with symptomatic-intracerebral hemorrhage (sICH) and 90-day functional outcome according to the modified Rankin Scale (mRS). We used multiplicative interaction terms between WML measures and IVT administration to evaluate IVT treatment effect modification. Regression models were used to report unadjusted and adjusted common odds ratios (cOR/acOR). RESULTS: In total, 516 patients from the MR CLEAN No-IV trial (male/female, 291/225; age median, 71 [IQR, 62-79]) were analyzed. Both DL-WML volume and WML-Faz are associated with sICH (DL-WML volume acOR, 1.78 [95%CI, 1.17; 2.70]; WML-Faz acOR, 1.53 95%CI [1.02; 2.31]) and mRS (DL-WML volume acOR, 0.70 [95%CI, 0.55; 0.87], WML-Faz acOR, 0.73 [95%CI 0.60; 0.88]). Only in the unadjusted IVT effect modification analysis WML-Faz was associated with more sICH if IVT was given (p = 0.046). Neither WML measure was associated with worse mRS if IVT was given. CONCLUSION: DL-WML volume and WML-Faz had a similar relationship with functional outcome and sICH. Although more sICH might occur in patients with more severe WML-Faz receiving IVT, no worse functional outcome was observed. CLINICAL RELEVANCE STATEMENT: White matter lesion severity on baseline CT in acute ischemic stroke patients has a similar predictive value if measured with deep learning or the Fazekas scale. Safe administration of intravenous thrombolysis using white matter lesion severity should be further studied. KEY POINTS: White matter damage is a predisposing risk factor for intracranial hemorrhage in patients with acute ischemic stroke but remains difficult to measure on CT. White matter lesion volume on CT measured with deep learning had a similar association with symptomatic intracerebral hemorrhages and worse functional outcome as the Fazekas scale. A patient-level meta-analysis is required to study the benefit of white matter lesion severity-based selection for intravenous thrombolysis before endovascular treatment.

2.
Med Image Anal ; 90: 102971, 2023 Dec.
Article in English | MEDLINE | ID: mdl-37778103

ABSTRACT

CT perfusion imaging is important in the imaging workup of acute ischemic stroke for evaluating affected cerebral tissue. CT perfusion analysis software produces cerebral perfusion maps from commonly noisy spatio-temporal CT perfusion data. High levels of noise can influence the results of CT perfusion analysis, necessitating software tuning. This work proposes a novel approach for CT perfusion analysis that uses physics-informed learning, an optimization framework that is robust to noise. In particular, we propose SPPINN: Spatio-temporal Perfusion Physics-Informed Neural Network and research spatio-temporal physics-informed learning. SPPINN learns implicit neural representations of contrast attenuation in CT perfusion scans using the spatio-temporal coordinates of the data and employs these representations to estimate a continuous representation of the cerebral perfusion parameters. We validate the approach on simulated data to quantify perfusion parameter estimation performance. Furthermore, we apply the method to in-house patient data and the public Ischemic Stroke Lesion Segmentation 2018 benchmark data to assess the correspondence between the perfusion maps and reference standard infarct core segmentations. Our method achieves accurate perfusion parameter estimates even with high noise levels and differentiates healthy tissue from infarcted tissue. Moreover, SPPINN perfusion maps accurately correspond with reference standard infarct core segmentations. Hence, we show that using spatio-temporal physics-informed learning for cerebral perfusion estimation is accurate, even in noisy CT perfusion data. The code for this work is available at https://github.com/lucasdevries/SPPINN.


Subject(s)
Brain Ischemia , Ischemic Stroke , Stroke , Humans , Tomography, X-Ray Computed/methods , Perfusion , Infarction , Stroke/diagnostic imaging , Brain Ischemia/diagnostic imaging , Cerebrovascular Circulation , Perfusion Imaging/methods
3.
Med Image Anal ; 85: 102749, 2023 Apr.
Article in English | MEDLINE | ID: mdl-36731276

ABSTRACT

CT perfusion imaging is commonly used for infarct core quantification in acute ischemic stroke patients. The outcomes and perfusion maps of CT perfusion software, however, show many discrepancies between vendors. We aim to perform infarct core segmentation directly from CT perfusion source data using machine learning, excluding the need to use the perfusion maps from standard CT perfusion software. To this end, we present a symmetry-aware spatio-temporal segmentation model that encodes the micro-perfusion dynamics in the brain, while decoding a static segmentation map for infarct core assessment. Our proposed spatio-temporal PerfU-Net employs an attention module on the skip-connections to match the dimensions of the encoder and decoder. We train and evaluate the method on 94 and 62 scans, respectively, using the Ischemic Stroke Lesion Segmentation (ISLES) 2018 challenge data. We achieve state-of-the-art results compared to methods that only use CT perfusion source imaging with a Dice score of 0.46. We are almost on par with methods that use perfusion maps from third party software, whilst it is known that there is a large variation in these perfusion maps from various vendors. Moreover, we achieve improved performance compared to simple perfusion map analysis, which is used in clinical practice.


Subject(s)
Brain Ischemia , Ischemic Stroke , Stroke , Humans , Stroke/pathology , Brain Ischemia/pathology , Cerebral Infarction , Tomography, X-Ray Computed/methods , Perfusion , Perfusion Imaging