Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 5 de 5
Filter
Add more filters










Database
Language
Publication year range
1.
Photochem Photobiol ; 84(1): 172-9, 2008.
Article in English | MEDLINE | ID: mdl-18173717

ABSTRACT

The diurnal and annual variability of solar UV radiation in Europe is described for different latitudes, seasons and different biologic weighting functions. For the description of this variability under cloudless skies the widely used one-dimensional version of the radiative transfer model UVSPEC is used. We reconfirm that the major factor influencing the diurnal and annual variability of UV irradiance is solar elevation. While ozone is a strong absorber of UV radiation its effect is relatively constant when compared with the temporal variability of clouds. We show the significant role that clouds play in modifying the UV climate by analyzing erythemal irradiance measurements from 28 stations in Europe in summer. On average, the daily erythemal dose under cloudless skies varies between 2.2 kJ m(-2) at 70 degrees N and 5.2 kJ m(-2) at 35 degrees N, whereas these values are reduced to 1.5-4.5 kJ m(-2) if clouds are included. Thus clouds significantly reduce the monthly UV irradiation, with the smallest reductions, on average, at lower latitudes, which corresponds to the fact that it is often cloudless in the Mediterranean area in summer.


Subject(s)
Ultraviolet Rays , Environmental Monitoring , Europe , Seasons , Weather
2.
Appl Opt ; 43(15): 3133-9, 2004 May 20.
Article in English | MEDLINE | ID: mdl-15176202

ABSTRACT

Direct ultraviolet spectral solar irradiance is regularly obtained by the difference between global and diffuse irradiances at the French Alpine station of Briançon; the data of years 2001 and 2002 are analyzed in this paper. Comparison with modeled values is used for cloud screening, and an average UV-A aerosol optical depth is used as an index of turbidity; it is found to be around 0.05 for the clear winter days and around 0.2 in summer. Langley plots are used to verify the instrument calibration; they confirm the expected uncertainty smaller than 5%. The ozone total column amount is estimated with an uncertainty between -3 and Dobson units; comparisons with TOMS (Total Ozone Mapping Spectrometer) overpass values shows agreement within the expected uncertainties of both instruments.

3.
Appl Opt ; 42(9): 1583-7, 2003 Mar 20.
Article in English | MEDLINE | ID: mdl-12665089

ABSTRACT

A measurement campaign was carried out in February 1998 at Briançon Station, French Alps (44.9 degrees N, 6.65 degrees E, 1,310 m above sea level) in order to determine the UV effective snow albedo that was retrieved for both erythemal and UV-A irradiances from measurements and modeling enhancement factors. The results are presented for 15 cloudless days with very variable snow cover and a small snowfall in the middle of the campaign. Erythemal irradiance enhancement due to the surface albedo was found to decrease from approximately +15% to +5% with a jump to +22% after the snowfall, whereas UV-A irradiance enhancement decreased from 7% to 5% and increased to 15% after the snowfall. Thesevalues fit to effective surface albedos of 0.4, 0.1, and 0.5 for erythemal, and to effective albedos of 0.25, 0.1, and 0.4 for UV-A irradiances, respectively. An unexpected difference between the effective albedos retrieved in the two wavelength regions can be explained by the difference of the environment contribution.

4.
Photochem Photobiol ; 76(2): 171-5, 2002 Aug.
Article in English | MEDLINE | ID: mdl-12194213

ABSTRACT

A multiple linear correlation is done between atmospheric transmissivity for four biologically active radiation daily doses (UVB, erythemal, DNA and plant damage) T, and three parameters (daily sunshine fraction sigma, cosine of the daily minimum solar zenith angle mu min and daily total ozone column omega). T is defined as the ratio of a daily dose to its extra-atmospheric value. The data used are spectral UV measurements (390-400 nm at 0.5 nm step) recorded along year 2000 and over 8 months of year 2001 at Briançon Station (Alps, 1300 m above sea level) that forms part of the French UV network. The coefficients obtained from year 2000 correlation permit to retrieve daily doses for year 2001 with an average error running from 3 to 9% for monthly mean values and from 2 to 4.5% for 3-monthly mean values, depending on daily dose type. The retrieval of yearly mean value gives an error between 4 and 7.5%. Retrieving the daily dose of a given day, where sigma > or = 0.2, introduces error running from 16 to 32% depending on daily dose. An attempt to retrieve the yearly mean UVB daily dose for a northern France site, from the previous coefficients, gives encouraging results.


Subject(s)
Photobiology , Ultraviolet Rays , DNA Damage , Erythema/etiology , France , Humans , Models, Biological , Plants/radiation effects , Radiation Dosage , Ultraviolet Rays/adverse effects
5.
Appl Opt ; 41(9): 1629-39, 2002 Mar 20.
Article in English | MEDLINE | ID: mdl-11921789

ABSTRACT

A measurement campaign was organized in March 1999 in the Bavarian Alps as part of the European project, Characteristics of the UV Radiation Field in the Alps (CUVRA), to analyze the effect of altitude, aerosols, and snow cover on ground-level UV spectral irradiance. We present the results of simultaneous measurements of aerosol optical depth (AOD) made at various sites on two cloudless days in March 1999. The two days exhibited different aerosol conditions. Results derived from spectral measurements of UV irradiance are compared with data from filter radiometer measurements made at discrete wavelengths extending from the UV to the near IR. The different methods generated values for the AOD that were in good agreement. This result confirms that one can use either method to retrieve the AOD with an uncertainty of approximately 0.03-0.05. On 18 March, high turbidity was observed at low altitude (400-nm AOD approximately 0.5 at 700 m above sea level), and the AOD decreased regularly with altitude; on 24 March, the turbidity was much less (0.11 at 700 m above sea level). On both days very low AODs (0.05-0.09) were measured at 3000 m above sea level. The spectral dependence of the AOD is often parameterized by the angstrom relationship; the alpha parameter is generally difficult or impossible to retrieve from spectral measurements because of the relatively narrow wavelength range (320-400 nm), and only one of the spectro-radiometers used during the campaign permits this retrieval. In most cases, during this field campaign, alpha was found by filter sunphotometers to be 1.1-1.5.

SELECTION OF CITATIONS
SEARCH DETAIL
...