Results 1 - 8 de 8
Filter
1.
BMC Cardiovasc Disord ; 21(1): 486, 2021 10 09.
Article in English | MEDLINE | ID: mdl-34627153

ABSTRACT

INTRODUCTION: Multi-parameter diagnostic devices can simplify cardiometabolic disease diagnosis. However, existing devices may not be suitable for use in low-resource settings, where the burden of non-communicable diseases is high. Here we describe the development of a target product profile (TPP) for a point-of-care multi-parameter device for detection of biomarkers for cardiovascular disease and metabolic disorders, including diabetes, in primary care settings in low- and middle-income countries (LMICs). METHODS: A draft TPP developed by an expert group was reviewed through an online survey and semi-structured expert interviews to identify device characteristics requiring refinement. The draft TPP included 41 characteristics with minimal and optimal requirements; characteristics with an agreement level for either requirement of ≤ 85% in either the survey or among interviewees were further discussed by the expert group and amended as appropriate. RESULTS: Twenty people responded to the online survey and 18 experts participated in the interviews. Twenty-two characteristics had an agreement level of ≤ 85% in either the online survey or interviews. The final TPP defines the device as intended to be used for basic diagnosis and management of cardiometabolic disorders (lipids, glucose, HbA1c, and creatinine) as minimal requirement, and offering an expanded test menu for wider cardiometabolic disease management as optimal requirement. To be suitable, the device should be intended for level 1 healthcare settings or lower, used by minimally trained healthcare workers and allow testing using self-contained cartridges or strips without the need for additional reagents. Throughput should be one sample at a time in a single or multi-analyte cartridge, or optimally enable testing of several samples and analytes in parallel with random access. CONCLUSION: This TPP will inform developers of cardiometabolic multi-parameter devices for LMIC settings, and will support decision makers in the evaluation of existing and future devices.


Subject(s)
Blood Chemical Analysis/instrumentation , Cardiovascular Diseases/diagnosis , Diabetes Mellitus/diagnosis , Metabolic Syndrome/diagnosis , Point-of-Care Systems , Point-of-Care Testing , Primary Health Care , Reagent Strips , Biomarkers/blood , Blood Glucose/analysis , Cardiovascular Diseases/blood , Consensus , Creatinine/blood , Delphi Technique , Diabetes Mellitus/blood , Equipment Design , Glycated Hemoglobin/analysis , Humans , Lipids/blood , Materials Testing , Metabolic Syndrome/blood , Predictive Value of Tests
2.
BMC Infect Dis ; 20(1): 117, 2020 Feb 10.
Article in English | MEDLINE | ID: mdl-32041536

ABSTRACT

BACKGROUND: Severe febrile illness without a known source (SFWS) is a challenge for clinicians when deciding how to manage a patient, particularly given the wide spectrum of potential aetiologies that contribute to fever. These infections are difficult to distinguish clinically, and accurate diagnosis requires a plethora of diagnostics including blood cultures, imaging techniques, molecular or serological tests, and more. When laboratory services are available, a limited test menu hinders clinical decision-making and antimicrobial stewardship, leading to empiric treatment and suboptimal patient outcomes. To specifically address SFWS, this work aimed to identify priority pathogens for a globally applicable panel for fever causing pathogens. METHOD: A pragmatic two-pronged approach combining currently available scientific data in an analytical hierarchy process and systematically gathered expert input, was designed to address the lack of comprehensive global aetiology data. The expert re-ranked list was then further adapted for a specific use case to focus on community acquired infections in whole blood specimens. The resulting list was further analysed to address different geographical regions (Asia, Africa, and Latin America), and Cohen kappa scores of agreement were calculated. RESULTS: The expert ranked prioritized pathogen list generated as part of this two-pronged approach included typhoidal Salmonella, Plasmodium species and Mycobacterium tuberculosis as the top 3 pathogens. This pathogen list was then further adapted for the SFWS use case to develop a final pathogen list to inform product development. Subsequent analysis comparing the relevance of the SFWS pathogen list to multiple populations and geographical regions showed that the SFWS prioritized list had considerable utility across Africa and Asia, but less so for Latin America. In addition, the list showed high levels of agreement across different patient sub-populations, but lower relevance for neonates and symptomatic HIV patients. CONCLUSION: This work highlighted once again the challenges of prioritising in global health, but it also shows that taking a two-pronged approach, combining available prevalence data with expert input, can result in a broadly applicable priority list. This comprehensive utility is particularly important in the context of product development, where a sufficient market size is essential to achieve a sustainable commercialized diagnostic product to address SFWS.


Subject(s)
Diagnostic Tests, Routine/standards , Fever/diagnosis , Africa/epidemiology , Asia/epidemiology , Community-Acquired Infections/diagnosis , Community-Acquired Infections/microbiology , Community-Acquired Infections/parasitology , Community-Acquired Infections/virology , Developing Countries , Fever/microbiology , Fever/parasitology , Fever/virology , Global Health/standards , Humans , Latin America/epidemiology , Prevalence
3.
Malar J ; 18(1): 443, 2019 Dec 26.
Article in English | MEDLINE | ID: mdl-31878947

ABSTRACT

BACKGROUND: Rapid diagnostic tests (RDT) for malaria are common, but their performance varies. Tests using histidine-rich protein 2 (HRP2) antigen are most common, and many have high sensitivity. HRP2 tests can remain positive for weeks after treatment, limiting their specificity and usefulness in high-transmission settings. Tests using Plasmodium lactate dehydrogenase (pLDH) have been less widely used but have higher specificity, mostly due to a much shorter time to become negative. METHODS: A prospective, health centre-based, diagnostic evaluation of two malaria RDTs was performed in rural Niger during the high malaria transmission season (3-28 October, 2017) and during the low transmission season (28 January-31 March, 2018). All children under 5 years of age presenting with fever (axillary temperature > 37.5 °C) or history of fever in the previous 24 h were eligible. Capillary blood was collected by finger prick. The SD Bioline HRP2 (catalog: 05FK50) and the CareStart pLDH(pan) (catalog: RMNM-02571) were performed in parallel, and thick and thin smears were prepared. Microscopy was performed at Epicentre, Maradi, Niger, with external quality control. The target sample size was 279 children with microscopy-confirmed malaria during each transmission season. RESULTS: In the high season, the sensitivity of both tests was estimated at > 99%, but the specificity of both tests was lower: 58.0% (95% CI 52.1-63.8) for the pLDH test and 57.4% (95% CI 51.5-63.1) for the HRP2 test. The positive predictive value was 66.3% (95% CI 61.1-71.2) for both tests. In the low season, the sensitivity of both tests dropped: 91.0% (95% CI 85.3-95.0) for the pLDH test and 85.8% (95% CI 79.3-90.9) for the HRP2 test. The positive predictive value remained low for both tests in the low season: 60.5% (95% CI 53.9-66.8) for the pLDH test and 61.9% (55.0-68.4) for the HRP2 test. Performance was similar across different production lots, gender, age of the children, and, during the high season, time since the most recent distribution of seasonal malaria chemoprevention. CONCLUSIONS: The low specificity of the pLDH RDT in this setting was unexpected and is not easily explained. As the pLDH test continues to be introduced into new settings, the questions raised by this study will need to be addressed.


Subject(s)
Antigens, Protozoan/isolation & purification , Diagnostic Tests, Routine/statistics & numerical data , L-Lactate Dehydrogenase/isolation & purification , Malaria, Falciparum/diagnosis , Plasmodium falciparum/isolation & purification , Protozoan Proteins/isolation & purification , Chemoprevention/statistics & numerical data , Child, Preschool , Female , Humans , Infant , Infant, Newborn , Male , Niger , Prospective Studies , Seasons
4.
J Acquir Immune Defic Syndr ; 82(1): 96-104, 2019 09 01.
Article in English | MEDLINE | ID: mdl-31408452

ABSTRACT

BACKGROUND: To assess the performance and suitability of dried blood spot (DBS) sampling using filter paper to collect blood for viral load (VL) quantification under routine conditions. METHODS: We compared performance of DBS VL quantification using the Biocentric method with plasma VL quantification using Roche and Biocentric as reference methods. Adults (≥18 years) were enrolled at 2 health facilities in Eswatini from October 12, 2016 to March 1, 2017. DBS samples were prepared through finger-prick by a phlebotomist (DBS-1), and through the pipetting of whole venous blood by a phlebotomist (DBS-2) and by a laboratory technologist (DBS-3). We calculated the VL-testing completion rate, correlation, and agreement, as well as diagnostic accuracy estimates at the clinical threshold of 1000 copies/mL. RESULTS: Of 362 patients enrolled, 1066 DBS cards (DBS-1: 347; DBS-2: 359; DBS-3: 360) were tested. Overall, test characteristics were comparable between DBS-sampling methods, irrespective of the reference method. The Pearson correlation coefficients ranged from 0.67 to 0.82 (P < 0.001) for different types of DBS sampling using both reference methods, and the Bland-Altman difference ranged from 0.15 to 0.30 log10 copies/mL. Sensitivity estimates were from 85.3% to 89.2% and specificity estimates were from 94.5% to 98.6%. The positive predictive values were between 87.0% and 96.5% at a prevalence of 30% VL elevations, and negative predictive values were between 93.7% and 95.4%. CONCLUSIONS: DBS VL quantification using the newly configured Biocentric method can be part of contextualized VL-testing strategies, particularly for remote settings and populations with higher viral failure rates.


Subject(s)
HIV Infections/blood , HIV Infections/diagnosis , Plasma/virology , Real-Time Polymerase Chain Reaction/methods , Viral Load/methods , Adult , Blood Specimen Collection , Dried Blood Spot Testing/methods , Eswatini , Female , HIV-1/genetics , Humans , Male , RNA, Viral/blood , Sensitivity and Specificity , Serologic Tests
5.
BMC Infect Dis ; 18(1): 570, 2018 Nov 14.
Article in English | MEDLINE | ID: mdl-30428850

ABSTRACT

BACKGROUND: Viral load (VL) testing is being scaled up in resource-limited settings. However, not all commercially available VL testing methods have been evaluated under field conditions. This study is one of a few to evaluate the Biocentric platform for VL quantification in routine practice in Sub-Saharan Africa. METHODS: Venous blood specimens were obtained from patients eligible for VL testing at two health facilities in Swaziland from October 2016 to March 2017. Samples were centrifuged at two laboratories (LAB-1, LAB-2) to obtain paired plasma specimens for VL quantification with the national reference method and on the Biocentric platform. Agreement (correlation, Bland-Altman) and accuracy (sensitivity, specificity) indicators were calculated at the VL thresholds of 416 (2.62 log10) and 1000 (3.0 log10) copies/mL. Leftover samples from patients with discordant VL results were re-quantified and accuracy indicators recalculated. Logistic regression was used to compare laboratory performance. RESULTS: A total of 364 paired plasma samples (LAB-1: n = 198; LAB-2: n = 166) were successfully tested using both methods. The correlation was high (R = 0.82, p < 0.01), and the Bland-Altman analysis showed a minimal mean difference (- 0.03 log10 copies/mL; 95% CI: -1.15 to 1.08). At the clinical threshold level of 3.0 log10 copies/mL, the sensitivity was 88.6% (95% CI: 78.7 to 94.9) and the specificity was 98.3% (95% CI: 96.1 to 99.4). Sensitivity was higher in LAB-1 (100%; 95% CI: 71.5 to 100) than in LAB-2 (86.4%; 95% CI: 75.0 to 94.0). Most upward (n = 8, 2.2%) and downward (n = 11, 3.0%) misclassifications occurred at the 2.62 log threshold, with LAB-2 having a 16 (95% CI: 2.26 to 113.27; p = 0.006) times higher odds of downward misclassification. After retesting of discordant leftover samples (n = 17), overall sensitivity increased to 93.5% (95% CI: 85.5 to 97.9) and 97.1% (95% CI: 90.1 to 99.7) at the 2.62 and 3.0 thresholds, and specificity increased to 98.6% (95% CI: 96.5 to 99.6) and 99.0% (95% CI: 97.0 to 99.8) respectively. CONCLUSIONS: The test characteristics of the Biocentric platform were overall comparable to the national reference method for VL quantification. One laboratory tended to misclassify VL results downwards, likely owing to unmet training needs and lack of previous hands-on practice.


Subject(s)
HIV Infections/diagnosis , HIV-1/genetics , RNA, Viral/blood , Real-Time Polymerase Chain Reaction/methods , Viral Load/methods , Adolescent , Adult , Diagnostic Tests, Routine/economics , Diagnostic Tests, Routine/methods , Diagnostic Tests, Routine/standards , Eswatini , Female , HIV Infections/blood , HIV Infections/virology , HIV-1/isolation & purification , Humans , Male , Middle Aged , Point-of-Care Systems/economics , Point-of-Care Systems/standards , Predictive Value of Tests , RNA, Viral/analysis , Reproducibility of Results , Sensitivity and Specificity , Serologic Tests , Specimen Handling/methods , Viral Load/genetics , Young Adult
6.
PLoS Negl Trop Dis ; 7(9): e2441, 2013.
Article in English | MEDLINE | ID: mdl-24086782

ABSTRACT

BACKGROUND: Visceral leishmaniasis (VL) is a systemic parasitic disease that is fatal unless treated. In Kenya, national VL guidelines rely on microscopic examination of spleen aspirate to confirm diagnosis. As this procedure is invasive, it cannot be safely implemented in peripheral health structures, where non-invasive, accurate, easy to use diagnostic tests are needed. METHODOLOGY: We evaluated the sensitivity, specificity and predictive values of two rapid diagnostic tests (RDT), DiaMed IT LEISH and Signal-KA, among consecutive patients with clinical suspicion of VL in two treatment centres located in Baringo and North Pokot District, Rift Valley province, Kenya. Microscopic examination of spleen aspirate was the reference diagnostic standard. Patients were prospectively recruited between May 2010 and July 2011. PRINCIPAL FINDINGS: Of 251 eligible patients, 219 patients were analyzed, including 131 VL and 88 non-VL patients. The median age of VL patients was 16 years with predominance of males (66%). None of the tested VL patients were co-infected with HIV. Sensitivity and specificity of the DiaMed IT LEISH were 89.3% (95%CI: 82.7-94%) and 89.8% (95%CI: 81.5-95.2%), respectively. The Signal KA showed trends towards lower sensitivity (77.1%; 95%CI: 68.9-84%) and higher specificity (95.5%; 95%CI: 88.7-98.7%). Combining the tests did not improve the overall diagnostic performance, as all patients with a positive Signal KA were also positive with the DiaMed IT LEISH. CONCLUSION/SIGNIFICANCE: The DiaMed IT LEISH can be used to diagnose VL in Kenyan peripheral health facilities where microscopic examination of spleen aspirate or sophisticated serological techniques are not feasible. There is a crucial need for an improved RDT for VL diagnosis in East Africa.


Subject(s)
Diagnostic Tests, Routine/methods , Leishmaniasis, Visceral/diagnosis , Adolescent , Adult , Aged , Child , Child, Preschool , Female , Humans , Kenya , Male , Middle Aged , Predictive Value of Tests , Prospective Studies , Sensitivity and Specificity , Young Adult
7.
Trop Med Int Health ; 17(12): 1457-64, 2012 Dec.
Article in English | MEDLINE | ID: mdl-23051824

ABSTRACT

OBJECTIVE: To assess the effectiveness of blood transfusions in a hospital of north-eastern Democratic Republic of the Congo. METHODS: Prospective study of children admitted for severe anaemia. During admission, data were collected on clinical condition and haemoglobin levels, before and after blood transfusion. A linear regression model was built to explore factors associated with haemoglobin level after transfusion. Risk factors for mortality were explored through multivariate logistic regression. RESULTS: Haemoglobin level (Hb) was below 4 g/dl in 35% (230/657), between 4 and 6 g/dl in 58% (348/657) and at least 6 g/dl in another 6% (43/657) of the transfused children. A transfusion of 15 ml/kg of whole blood increased the Hb from 4.4 to 7.8 g/dl. Haemoglobin level after transfusion was associated with baseline Hb, quantity of delivered blood and history of previous transfusions. Overall case-fatality rate was 5.6% (37/657). Risk factors for deaths were co-morbidities such as chest infection, meningitis or malnutrition, Hb ≥ 6 g/dl, impaired consciousness or jugular venous distention on admission, and provenance. CONCLUSION: Transfusion was a frequent practice, the use of which could clearly have been rationalised. While indications should be restricted, quantities of transfused blood should be adapted to needs.


Subject(s)
Anemia/mortality , Anemia/therapy , Blood Transfusion , Child, Preschool , Comorbidity , Democratic Republic of the Congo/epidemiology , Female , Hemoglobins/metabolism , Hospital Mortality , Humans , Infant , Linear Models , Logistic Models , Male , Multivariate Analysis , Prospective Studies , Risk Factors , Transfusion Reaction
8.
Emerg Infect Dis ; 18(1): 29-37, 2012 Jan.
Article in English | MEDLINE | ID: mdl-22260950

ABSTRACT

In Africa, although emergence of multidrug-resistant (MDR) tuberculosis (TB) represents a serious threat in countries severely affected by the HIV epidemic, most countries lack drug-resistant TB data. This finding was particularly true in the Kingdom of Swaziland, which has the world's highest HIV and TB prevalences. Therefore, we conducted a national survey in 2009-2010 to measure prevalence of drug-resistant TB. Of 988 patients screened, 420 new case-patients and 420 previously treated case-patients met the study criteria. Among culture-positive patients, 15.3% new case-patients and 49.5% previously treated case-patients harbored drug-resistant strains. MDR TB prevalence was 7.7% and 33.8% among new case-patients and previously treated case-patients, respectively. HIV infection and past TB treatment were independently associated with MDR TB. The findings assert the need for wide-scale intervention in resource-limited contexts such as Swaziland, where diagnostic and treatment facilities and health personnel are lacking.


Subject(s)
Antimalarials/pharmacology , Tuberculosis, Multidrug-Resistant/epidemiology , Adolescent , Adult , Cross-Sectional Studies , Drug Resistance, Multiple, Bacterial , Eswatini/epidemiology , Female , Humans , Male , Population Surveillance , Prevalence , Tuberculosis, Pulmonary/epidemiology , Tuberculosis, Pulmonary/microbiology , Young Adult