ABSTRACT
In order to obtain power spectral information on the fetal heart rate in stages of pregnancy earlier than labor an algorithm has been developed to calculate the fetal heart rate on a beat-to-beat basis from Doppler ultrasound cardiotocographic signals. The algorithm was evaluated by comparing the calculated fetal heart rate with the heart rate determined from direct ECG signals measured with a scalp electrode. Heart rates were compared both in time and frequency domain. In the time domain the results achieved by both methods correlate well (correlation coefficient = 0.977 (p < 0.001)), in the frequency domain the results correlate even better (correlation coefficient = 0.991 (p < 0.001)). Based on these findings, it can be concluded that the developed algorithm provides a valuable tool for obtaining power spectral information on the fetal heart rate in stages of pregnancy earlier than labor.
Subject(s)
Cardiotocography/methods , Electrocardiography/methods , Heart Rate, Fetal/physiology , Ultrasonography, Prenatal/methods , Female , Fetal Monitoring/methods , Humans , Pregnancy , Time Factors , Ultrasonography, Doppler/methodsABSTRACT
To examine the baroreceptor reflex function, a beat-to-beat analysis between systolic blood pressure (SBP) and R-R interval fluctuations was studied in 10 stable appropriate-for-gestational age preterm infants (range, 27.2-33.7 wk) in the first postnatal week during quiet sleep. Spectral power analysis, using fast Fourier transform, and transfer functions (gain and phase difference) between SBP and R-R fluctuations were estimated in a low-frequency band (LF, 0.03-0.2 Hz) and high-frequency band (HF defined as the frequency band between the 10th and 90th centiles of the individual respiratory frequency). The LF/HF ratio reflects the sympathovagal balance. The mean frequency (+/-SD) of LF peaks was centered at 0.07 +/- 0.02 Hz. The mean frequency (+/-SD) of the individual HF band was 0.82 +/- 0.21 Hz. The LF/HF ratio in the R-R interval series [median, 29; interquartile range (IQR), 16-40] was higher than in the SBP series (median, 8; IQR, 4-14). The gain between R-R interval and SBP fluctuations (median, 4.2 ms/mm Hg; IQR, 2.4-5.0) in the LF band was higher than in the HF band (median, 1.7 ms/mm Hg; IQR, 1.4-3.0). SBP fluctuations lead R-R interval fluctuations in the LF band with a median phase difference of +96 degrees (IQR, 67-132). At LF the fluctuations in SBP precede changes in R-R interval with a time delay of 3.8 s. These observations indicate a dominant role of the sympathetic system in stable preterm infants in comparison with published adult values. Cross-spectral analysis allows a test for tracking the development of the sympathetic system in neonates.