Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 2 de 2
Filter
Add more filters










Database
Language
Publication year range
1.
Int J Qual Health Care ; 33(4)2021 Nov 27.
Article in English | MEDLINE | ID: mdl-34791294

ABSTRACT

DESIGN: A two-phase prospective intervention study. OBJECTIVE: The objective of this study was to determine if feedback of adenosine triphosphate (ATP) measurements decreases environmental contamination within hospitals in the Dutch/Belgian border area. METHODS: Standardized ATP measurements were conducted in nine hospitals on pre-defined fomites. Four different fomite groups were defined: medical devices, patient-bound materials, ward-bound materials and sanitary items. ATP results were reported in relative light unit (RLU), RLU >1000 was considered as 'not clean.' Two rounds of ATP measurements were conducted. After the first round of ATP measurements, results were provided to the wards and cleaning staff. The second round of ATP measurements was performed one year later. The amount of surface contamination before and after the feedback was compared. RESULTS: In total 1923 ATP measurements were performed. Before feedback 960 ATP measurements were conducted and after feedback 963 were conducted. The overall median reduction in RLU was 381 (P < 0.001), from 568 before feedback to 187 afterward. In each hospital there was a reduction of the median RLU after feedback. CONCLUSIONS: Substantial reductions in RLU values were found after feedback of ATP measurements. Feedback of ATP measurement in itself was associated with a major reduction of surface contamination in hospitals.


Subject(s)
Adenosine Triphosphate , Infection Control , Belgium , Feedback , Hospitals , Humans , Prospective Studies
2.
Antimicrob Resist Infect Control ; 9(1): 77, 2020 05 28.
Article in English | MEDLINE | ID: mdl-32466792

ABSTRACT

BACKGROUND: The objective of this study was to determine the level of environmental contamination in hospitals in the Dutch/Belgian border area, using ATP measurements. DESIGN: A cross-sectional observational survey. METHODS: Standardized ATP measurements were conducted in 9 hospitals on 32 hospital wards. Thirty pre-defined surfaces per hospital ward were measured with the 3 M Clean Trace NG luminometer. Results are displayed in relative light units (RLU). RLU > 1000 was considered as "not clean." Differences in RLU values were compared between countries, hospitals, fomite groups and medical specialties. RESULTS: A total of 960 ATP measurements were performed, ranging from 60 up to 120 per hospital. The median RLU-value was 568 (range: 3-277,586) and 37.7% of the measurements were rated as not clean (RLU > 1000). There were significant differences between countries, hospitals and fomite groups. CONCLUSION: ATP measurements can be used as a more objective approach to determine the level of environmental contamination in hospitals. Significant differences in ATP levels were found between hospitals and between countries. Also, substantial differences were found between different fomite groups. These findings offer potential targets for improvement of cleanliness in healthcare facilities.


Subject(s)
Adenosine Triphosphate/analysis , Bacteria/isolation & purification , Fomites/microbiology , Belgium , Cross-Sectional Studies , Equipment Contamination , Hospitals , Humans , Infection Control , Luminescent Measurements , Netherlands
SELECTION OF CITATIONS
SEARCH DETAIL
...