Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 4 de 4
Filter
Add more filters










Database
Language
Publication year range
1.
Arch Orthop Trauma Surg ; 141(11): 1899-1907, 2021 Nov.
Article in English | MEDLINE | ID: mdl-33128609

ABSTRACT

INTRODUCTION: Due to the variation in shape and curvature of the clavicle, plates often have to be adjusted during surgery to acquire a good fit. Poorly fitted plates can cause discomfort, eventually requiring implant removal. 3D-printed replicas of the fractured clavicle can assist in planning of the surgical approach, plate selection and, if necessary, adjustment of the plate prior to surgery. We hypothesized this method of preoperative preparation would reduce implant-related discomfort resulting in a reduced reoperation rate MATERIALS AND METHODS: In a prospective cohort study, perioperative plate handling and clavicle fixation were timed and follow-up data were collected from participants undergoing operative treatment for a midshaft clavicle fracture. The control group (n = 7) received conventional surgery with standard precontoured plates. For the intervention group (n = 7), 3D-printed replicas of the fractured clavicle and a mirrored version of the healthy contralateral clavicle were available prior to surgery for planning of the surgical approach, and for plate selection and contouring. Primary outcome was reoperation rate due to implant-related discomfort. Secondary outcomes were complications and time differences in the different surgical phases (reduction, fixation and overall operation time) RESULTS: More participants in the control group had the plate removed due to discomfort compared to the intervention group (5/7 vs. 0/6; P = 0.012). One participant was excluded from the intervention group due to a postoperative complication; an infection occurred at the implant site. No relevant time difference in surgical plate handling was found between both groups. CONCLUSIONS: Preoperative preparation using 3D-printed replicas of the clavicle fracture may reduce implant removal caused by plated-related discomfort. No relevant effect on surgery time was found. TRIAL REGISTRATION: Registered with 'toetsingonline.nl', trial number NL51269.075/14, 17-02-2015.


Subject(s)
Clavicle , Fractures, Bone , Bone Plates , Clavicle/surgery , Follow-Up Studies , Fracture Fixation, Internal , Fractures, Bone/surgery , Humans , Printing, Three-Dimensional , Prospective Studies , Retrospective Studies , Treatment Outcome
2.
J Diabetes Sci Technol ; 14(1): 46-54, 2020 01.
Article in English | MEDLINE | ID: mdl-31200612

ABSTRACT

BACKGROUND: Thermal assessment of the plantar surface of the foot using spot thermometers and thermal imaging has been proven effective in diabetic foot ulcer prevention. However, with traditional cameras this is limited to single spots or a two-dimensional (2D) view of the plantar side of foot, where only 50% of the ulcers occur. To improve ulcer detection, the view has to be extended beyond 2D. Our aim is to explore for proof of concept the combination of three-dimensional (3D) models with thermal imaging for inflammation detection in diabetic foot disease. METHOD: From eight participants with a current diabetic foot ulcer we simultaneously acquired a 3D foot model and three thermal infrared images using a high-resolution medical 3D imaging system aligned with three smartphone-based thermal infrared cameras. Using spatial transformations, we aimed to map thermal images onto the 3D model, to create the 3D visualizations. Expert clinicians assessed these for quality and face validity as +, +/-, -. RESULTS: We could replace the texture maps (color definitions) of the 3D model with the thermal infrared images and created the first-ever 3D thermographs of the diabetic foot. We then converted these models to 3D PDF-files compatible with the hospital IT environment. Face validity was assessed as + in six and +/- in two cases. CONCLUSIONS: We have provided a proof of concept for the creation of clinically useful 3D thermal foot images to assess the diabetic foot skin temperature in 3D in a hospital IT environment. Future developments are expected to improve the image-processing techniques to result in easier, handheld applications and driving further research.


Subject(s)
Diabetic Foot/diagnosis , Foot/physiopathology , Inflammation/diagnosis , Skin Temperature/physiology , Thermography/methods , Aged , Aged, 80 and over , Cross-Sectional Studies , Diabetic Foot/physiopathology , Female , Humans , Image Processing, Computer-Assisted , Inflammation/physiopathology , Male , Middle Aged , Proof of Concept Study , Prospective Studies
4.
Plast Reconstr Surg Glob Open ; 4(12): e1146, 2016 Dec.
Article in English | MEDLINE | ID: mdl-28293505

ABSTRACT

BACKGROUND: The limited cranial skin covering auricular implants is an important yet underrated factor in auricular reconstruction for both reconstruction surgery and tissue engineering strategies. We report exact measurements on skin deficiency in microtia patients and propose an accessible preoperative method for these measurements. METHODS: Plaster ear models (n = 11; male:female = 2:1) of lobular-type microtia patients admitted to the University Medical Center Utrecht in The Netherlands were scanned using a micro-computed tomographic scanner or a cone-beam computed tomographic scanner. The resulting images were converted into mesh models from which the surface area could be calculated. RESULTS: The mean total skin area of an adult-size healthy ear was 47.3 cm2, with 49.0 cm2 in men and 44.3 cm2 in women. Microtia ears averaged 14.5 cm2, with 15.6 cm2 in men and 12.6 cm2 in women. The amount of skin deficiency was 25.4 cm2, with 26.7 cm2 in men and 23.1 cm2 in women. CONCLUSIONS: This study proposes a novel method to provide quantitative data on the skin surface area of the healthy adult auricle and the amount of skin deficiency in microtia patients. We demonstrate that the microtia ear has less than 50% of skin available compared with healthy ears. Limited skin availability in microtia patients can lead to healing problems after auricular reconstruction and poses a significant challenge in the development of tissue-engineered cartilage implants. The results of this study could be used to evaluate outcomes and investigate new techniques with regard to tissue-engineered auricular constructs.

SELECTION OF CITATIONS
SEARCH DETAIL
...