Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 4 de 4
Filter
Add more filters










Database
Language
Publication year range
1.
Int J Audiol ; 57(11): 864-871, 2018 11.
Article in English | MEDLINE | ID: mdl-30261773

ABSTRACT

The condition of the auditory nerve is a factor determining hearing performance of cochlear implant (CI) recipients. Abnormal loudness adaptation is associated with poor auditory nerve survival. We examined which stimulus conditions are suitable for tone decay measurements to differentiate between CI recipients with respect to their speech perception. Tone decay was defined here as occurring when the percept disappears before the stimulus stops. We measured the duration of the percept of a 60-s pulse train. Current levels ranged from below threshold up to maximum acceptable loudness, pulse rates from 250 to 5000 pulses/s, and duty cycles (percentages of time the burst of pulses is on) from 10% to 100%. Ten adult CI recipients were included: seven with good and three with poor speech perception. Largest differences among the subjects were found at 5000 pulses/s and 100% duty cycle. The well performing subjects had a continuous percept of the 60-s stimulus within 3 dB above threshold. Two poorly performing subjects showed abnormal loudness adaptation, that is, no continuous percept even at levels greater than 6 dB above threshold. We conclude that abnormal loudness adaptation can be detected via an electric tone decay test using a high pulse rate and 100% duty cycle.


Subject(s)
Adaptation, Psychological , Cochlear Implantation/instrumentation , Cochlear Implants , Cochlear Nerve/physiopathology , Deafness/rehabilitation , Loudness Perception , Persons With Hearing Impairments/rehabilitation , Speech Perception , Acoustic Stimulation , Aged , Aged, 80 and over , Auditory Threshold , Deafness/diagnosis , Deafness/physiopathology , Deafness/psychology , Electric Stimulation , Female , Humans , Male , Middle Aged , Persons With Hearing Impairments/psychology , Psychoacoustics , Signal Detection, Psychological , Time Factors
2.
Otol Neurotol ; 39(6): 707-714, 2018 07.
Article in English | MEDLINE | ID: mdl-29889780

ABSTRACT

HYPOTHESIS: A cochlear implant (CI) restores hearing in patients with profound sensorineural hearing loss by electrical stimulation of the auditory nerve. It is unknown how this electrical stimulation sounds. BACKGROUND: Patients with single-sided deafness (SSD) and a CI form a unique population, since they can compare the sound of their CI with simulations of the CI sound played to their nonimplanted ear. METHODS: We tested six stimuli (speech and music) in 10 SSD patients implanted with a CI (Cochlear Ltd). Patients listened to the original stimulus with their CI ear while their nonimplanted ear was masked. Subsequently, patients listened to two CI simulations, created with a vocoder, with their nonimplanted ear alone. They selected the CI simulation with greatest similarity to the sound as perceived by their CI ear and they graded similarity on a 1 to 10 scale. We tested three vocoders: two known from the literature, and one supplied by Cochlear Ltd. Two carriers (noise, sine) were tested for each vocoder. RESULTS: Carrier noise and the vocoders from the literature were most often selected as best match to the sound as perceived by the CI ear. However, variability in selections was substantial both between patients and within patients between sound samples. The average grade for similarity was 6.8 for speech stimuli and 6.3 for music stimuli. CONCLUSION: We obtained a fairly good impression of what a CI can sound like for SSD patients. This may help to better inform and educate patients and family members about the sound of a CI.


Subject(s)
Auditory Perception , Cochlear Implants , Hearing Loss, Sensorineural/surgery , Adult , Cochlear Implantation , Female , Hearing Loss, Unilateral/surgery , Humans , Male , Middle Aged
3.
Laryngoscope ; 127(2): 476-487, 2017 02.
Article in English | MEDLINE | ID: mdl-27804133

ABSTRACT

OBJECTIVES/HYPOTHESIS: The variability in speech perception between cochlear implant users is thought to result from the degeneration of the auditory nerve. Degeneration of the auditory nerve, histologically assessed, correlates with electrophysiologically acquired measures, such as electrically evoked compound action potentials (eCAPs) in experimental animals. To predict degeneration of the auditory nerve in humans, where histology is impossible, this paper reviews the correlation between speech perception and eCAP recordings in cochlear implant patients. DATA SOURCES: PubMed and Embase. REVIEW METHODS: We performed a systematic search for articles containing the following major themes: cochlear implants, evoked potentials, and speech perception. Two investigators independently conducted title-abstract screening, full-text screening, and critical appraisal. Data were extracted from the remaining articles. RESULTS: Twenty-five of 1,429 identified articles described a correlation between speech perception and eCAP attributes. Due to study heterogeneity, a meta-analysis was not feasible, and studies were descriptively analyzed. Several studies investigating presence of the eCAP, recovery time constant, slope of the amplitude growth function, and spatial selectivity showed significant correlations with speech perception. In contrast, neural adaptation, eCAP threshold, and change with varying interphase gap did not significantly correlate with speech perception in any of the identified studies. CONCLUSIONS: Significant correlations between speech perception and parameters obtained through eCAP recordings have been documented in literature; however, reporting was ambiguous. There is insufficient evidence for eCAPs as a predictive factor for speech perception. More research is needed to further investigate this relation. Laryngoscope, 2016 127:476-487, 2017.


Subject(s)
Cochlear Implants , Cochlear Nerve/physiopathology , Evoked Potentials/physiology , Hearing Loss, Sensorineural/physiopathology , Hearing Loss, Sensorineural/rehabilitation , Nerve Degeneration/physiopathology , Speech Perception/physiology , Adolescent , Adult , Aged , Aged, 80 and over , Child , Child, Preschool , Electric Stimulation , Humans , Middle Aged , Statistics as Topic , Young Adult
4.
J Assoc Res Otolaryngol ; 16(5): 669-78, 2015 Oct.
Article in English | MEDLINE | ID: mdl-26162414

ABSTRACT

Neurophysiological studies in animals and humans suggest that severe hearing loss during early development impairs the maturation of the auditory brainstem. To date, studies in humans have mainly focused on the neural activation of the auditory brainstem in children treated with a cochlear implant (CI), but little is known about the pattern of activation in adult CI users with early onset of deafness (prelingual, before the age of 2 years). In this study, we compare auditory brainstem activation in prelingually deaf and late-implanted adult CI users to that in postlingually deaf CI users. Electrically evoked auditory brainstem responses (eABRs) were recorded by monopolar stimulation, separately using a middle and an apical electrode of the CI. Comparison of the eABR latencies revealed that wave V was significantly delayed in the prelingually deaf CI users on both electrode locations. Accordingly, when the apical electrode was stimulated, the III-V interwave interval was significantly longer in the prelingually deaf group. These findings suggest a slower neural conduction in the auditory brainstem, probably caused by impairment of maturation during the long duration of severe hearing loss in infancy. Shorter wave V latencies, reflecting a more mature brainstem, appeared to be a predictor for better speech perception.


Subject(s)
Cochlear Implants , Deafness/physiopathology , Evoked Potentials, Auditory, Brain Stem/physiology , Adult , Aged , Cerebral Cortex/physiology , Humans , Middle Aged , Reaction Time , Speech Perception
SELECTION OF CITATIONS
SEARCH DETAIL
...