Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 20 de 34
Filter
1.
Physiol Meas ; 45(5)2024 May 15.
Article in English | MEDLINE | ID: mdl-38653318

ABSTRACT

Objective.Sleep staging based on full polysomnography is the gold standard in the diagnosis of many sleep disorders. It is however costly, complex, and obtrusive due to the use of multiple electrodes. Automatic sleep staging based on single-channel electro-oculography (EOG) is a promising alternative, requiring fewer electrodes which could be self-applied below the hairline. EOG sleep staging algorithms are however yet to be validated in clinical populations with sleep disorders.Approach.We utilized the SOMNIA dataset, comprising 774 recordings from subjects with various sleep disorders, including insomnia, sleep-disordered breathing, hypersomnolence, circadian rhythm disorders, parasomnias, and movement disorders. The recordings were divided into train (574), validation (100), and test (100) groups. We trained a neural network that integrated transformers within a U-Net backbone. This design facilitated learning of arbitrary-distance temporal relationships within and between the EOG and hypnogram.Main results.For 5-class sleep staging, we achieved median accuracies of 85.0% and 85.2% and Cohen's kappas of 0.781 and 0.796 for left and right EOG, respectively. The performance using the right EOG was significantly better than using the left EOG, possibly because in the recommended AASM setup, this electrode is located closer to the scalp. The proposed model is robust to the presence of a variety of sleep disorders, displaying no significant difference in performance for subjects with a certain sleep disorder compared to those without.Significance.The results show that accurate sleep staging using single-channel EOG can be done reliably for subjects with a variety of sleep disorders.


Subject(s)
Electrooculography , Sleep Stages , Sleep Wake Disorders , Humans , Sleep Stages/physiology , Electrooculography/methods , Sleep Wake Disorders/diagnosis , Sleep Wake Disorders/physiopathology , Male , Female , Adult , Cohort Studies , Middle Aged , Signal Processing, Computer-Assisted , Neural Networks, Computer , Young Adult , Polysomnography
2.
Sleep Med ; 117: 152-161, 2024 May.
Article in English | MEDLINE | ID: mdl-38547592

ABSTRACT

OBJECTIVE: To explore sleep structure in participants with obstructive sleep apnea (OSA) and comorbid insomnia (COMISA) and participants with OSA without insomnia (OSA-only) using both single-night polysomnography and multi-night wrist-worn photoplethysmography/accelerometry. METHODS: Multi-night 4-class sleep-staging was performed with a validated algorithm based on actigraphy and heart rate variability, in 67 COMISA (23 women, median age: 51 years) and 50 OSA-only (15 women, median age: 51) participants. Sleep statistics were compared using linear regression models and mixed-effects models. Multi-night variability was explored using a clustering approach and between- and within-participant analysis. RESULTS: Polysomnographic parameters showed no significant group differences. Multi-night measurements, during 13.4 ± 5.2 nights per subject, demonstrated a longer sleep onset latency and lower sleep efficiency for the COMISA group. Detailed analysis of wake parameters revealed longer mean durations of awakenings in COMISA, as well as higher numbers of awakenings lasting 5 min and longer (WKN≥5min) and longer wake after sleep onset containing only awakenings of 5 min or longer. Within-participant variance was significantly larger in COMISA for sleep onset latency, sleep efficiency, mean duration of awakenings and WKN≥5min. Unsupervised clustering uncovered three clusters; participants with consistently high values for at least one of the wake parameters, participants with consistently low values, and participants displaying higher variability. CONCLUSION: Patients with COMISA more often showed extended, and more variable periods of wakefulness. These observations were not discernible using single night polysomnography, highlighting the relevance of multi-night measurements to assess characteristics indicative for insomnia.


Subject(s)
Sleep Apnea, Obstructive , Sleep Initiation and Maintenance Disorders , Humans , Female , Middle Aged , Sleep/physiology , Polysomnography , Sleep Apnea, Obstructive/complications , Sleep Apnea, Obstructive/diagnosis , Actigraphy
3.
Sleep Breath ; 2023 Dec 07.
Article in English | MEDLINE | ID: mdl-38062226

ABSTRACT

PURPOSE: Comorbid insomnia often occurs in patients with obstructive sleep apnea (OSA), referred to as COMISA. Cortical arousals manifest as a common feature in both OSA and insomnia, often accompanied by elevated heart rate (HR). Our objective was to evaluate the heart rate response to nocturnal cortical arousals in patients with COMISA and patients with OSA alone. METHODS: We analyzed data from patients with COMISA and from patients with OSA matched for apnea-hypopnea index. Sleep staging and analysis of respiratory events and cortical arousals were performed using the Philips Somnolyzer automatic scoring system. Beat-by-beat HR was analyzed from the onset of the cortical arousal to 30 heartbeats afterwards. HR responses were divided into peak and recovery phases. Cortical arousals were separately evaluated according to subtype (related to respiratory events and spontaneous) and duration (3-6 s, 6-10 s, 10-15 s). RESULTS: A total of 72 patients with COMISA and 72 patients with OSA were included in this study. There were no overall group differences in the number of cortical arousals with and without autonomic activation. No significant differences were found for spontaneous cortical arousals. The OSA group had more cortical arousals related to respiratory events (21.0 [14.8-30.0] vs 16.0 [9.0-27.0], p = 0.016). However, the COMISA group had longer cortical arousals (7.2 [6.4-7.8] vs 6.7 [6.2-7.7] s, p = 0.024) and the HR recovery phase was prolonged (52.5 [30.8-82.5] vs 40.0 [21.8-55.5] beats/min, p = 0.017). Both the peak and the recovery phase for longer cortical arousals with a duration of 10-15 s were significantly higher in patients with COMISA compared to patients with OSA (47.0 [27.0-97.5] vs 34.0 [21.0-71.0] beats/min, p = 0.032 and 87.0 [47.0-132.0] vs 71.0 [43.0-103.5] beats/min, p = 0.049, respectively). CONCLUSIONS: The HR recovery phase after cortical arousals related to respiratory events is prolonged in patients with COMISA compared to patients with OSA alone. This response could be indicative of the insomnia component in COMISA.

4.
J Sleep Res ; : e14096, 2023 Dec 09.
Article in English | MEDLINE | ID: mdl-38069589

ABSTRACT

Non-rapid eye movement parasomnia disorders, also called disorders of arousal, are characterized by abnormal nocturnal behaviours, such as confusional arousals or sleep walking. Their pathophysiology is not yet fully understood, and objective diagnostic criteria are lacking. It is known, however, that behavioural episodes occur mostly in the beginning of the night, after an increase in slow-wave activity during slow-wave sleep. A better understanding of the prospect of such episodes may lead to new insights in the underlying mechanisms and eventually facilitate objective diagnosis. We investigated temporal dynamics of transitions from slow-wave sleep of 52 patients and 79 controls. Within the patient group, behavioural and non-behavioural N3 awakenings were distinguished. Patients showed a higher probability to wake up after an N3 bout ended than controls, and this probability increased with N3 bout duration. Bouts longer than 15 min resulted in an awakening in 73% and 34% of the time in patients and controls, respectively. Behavioural episodes reduced over sleep cycles due to a reduction in N3 sleep and a reducing ratio between behavioural and non-behavioural awakenings. In the first two cycles, N3 bouts prior to non-behavioural awakenings were significantly shorter than N3 bouts advancing behavioural awakenings in patients, and N3 awakenings in controls. Our findings provide insights in the timing and prospect of both behavioural and non-behavioural awakenings from N3, which may result in prediction and potentially prevention of behavioural episodes. This work, moreover, leads to a more complete characterization of a prototypical hypnogram of parasomnias, which could facilitate diagnosis.

5.
J Appl Physiol (1985) ; 135(5): 1199-1212, 2023 11 01.
Article in English | MEDLINE | ID: mdl-37767554

ABSTRACT

Pregnancy complications are associated with abnormal maternal autonomic regulation. Subsequently, thoroughly understanding maternal autonomic regulation during healthy pregnancy may enable the earlier detection of complications, in turn allowing for the improved management thereof. Under healthy autonomic regulation, reciprocal interactions occur between the cardiac and respiratory systems, i.e., cardiorespiratory coupling (CRC). Here, we investigate, for the first time, the differences in CRC between healthy pregnant and nonpregnant women. We apply two algorithms, namely, synchrograms and bivariate phase-rectified signal averaging, to nighttime recordings of ECG and respiratory signals. We find that CRC is present in both groups. Significantly less (P < 0.01) cardiorespiratory synchronization occurs in pregnant women (11% vs. 15% in nonpregnant women). Moreover, there is a smaller response in the heart rate of pregnant women corresponding to respiratory inhalations and exhalations. In addition, we stratified these analyses by sleep stages. As each sleep stage is governed by different autonomic states, this stratification not only amplified some of the differences between groups but also brought out differences that remained hidden when analyzing the full-night recordings. Most notably, the known positive relationship between CRC and deep sleep is less prominent in pregnant women than in their nonpregnant counterparts. The decrease in CRC during healthy pregnancy may be attributable to decreased maternal parasympathetic activity, anatomical changes to the maternal respiratory system, and the increased physiological stress accompanying pregnancy. This work offers novel insight into the physiology of healthy pregnancy and forms part of the base knowledge needed to detect abnormalities in pregnancy.NEW & NOTEWORTHY We compare CRC, i.e., the reciprocal interaction between the cardiac and respiratory systems, between healthy pregnant and nonpregnant women for the first time. Although CRC is present in both groups, CRC is reduced during healthy pregnancy; there is less synchronization between maternal cardiac and respiratory activity and a smaller response in maternal heart rate to respiratory inhalations and exhalations. Stratifying this analysis by sleep stages reveals that differences are most prominent during deep sleep.


Subject(s)
Autonomic Nervous System , Pregnancy Complications , Humans , Female , Pregnancy , Autonomic Nervous System/physiology , Heart , Sleep Stages/physiology , Exhalation
6.
IEEE J Biomed Health Inform ; 27(11): 5599-5609, 2023 11.
Article in English | MEDLINE | ID: mdl-37561616

ABSTRACT

Sleep staging is the process by which an overnight polysomnographic measurement is segmented into epochs of 30 seconds, each of which is annotated as belonging to one of five discrete sleep stages. The resulting scoring is graphically depicted as a hypnogram, and several overnight sleep statistics are derived, such as total sleep time and sleep onset latency. Gold standard sleep staging as performed by human technicians is time-consuming, costly, and comes with imperfect inter-scorer agreement, which also results in inter-scorer disagreement about the overnight statistics. Deep learning algorithms have shown promise in automating sleep scoring, but struggle to model inter-scorer disagreement in sleep statistics. To that end, we introduce a novel technique using conditional generative models based on Normalizing Flows that permits the modeling of the inter-rater disagreement of overnight sleep statistics, termed U-Flow. We compare U-Flow to other automatic scoring methods on a hold-out test set of 70 subjects, each scored by six independent scorers. The proposed method achieves similar sleep staging performance in terms of accuracy and Cohen's kappa on the majority-voted hypnograms. At the same time, U-Flow outperforms the other methods in terms of modeling the inter-rater disagreement of overnight sleep statistics. The consequences of inter-rater disagreement about overnight sleep statistics may be great, and the disagreement potentially carries diagnostic and scientifically relevant information about sleep structure. U-Flow is able to model this disagreement efficiently and can support further investigations into the impact inter-rater disagreement has on sleep medicine and basic sleep research.


Subject(s)
Sleep Stages , Sleep , Humans , Polysomnography/methods , Observer Variation , Reproducibility of Results , Electroencephalography/methods
7.
J Clin Sleep Med ; 19(6): 1051-1059, 2023 06 01.
Article in English | MEDLINE | ID: mdl-36740913

ABSTRACT

STUDY OBJECTIVES: Obstructive sleep apnea (OSA) and insomnia frequently co-occur, making diagnosis and treatment challenging. We investigated differences in sleep structure between patients with OSA, insomnia, and comorbid insomnia and sleep apnea (COMISA) to identify characteristics that can be used to improve the diagnosis of COMISA. METHODS: We obtained polysomnography data of 326 patients from the Sleep and OSA Monitoring with Non-Invasive Applications database. The group included patients with OSA (n = 199), insomnia (n = 47), and COMISA (n = 80). We compared statistics related to sleep structure between the 3 patient groups. RESULTS: Wake after sleep onset was significantly shorter for the OSA group (median: 60.0 minutes) compared to the COMISA (median: 83.3 minutes, P < .01) and the insomnia (median: 83.5 minutes, P = .01) groups. No significant differences were found in the total number of awakenings and the number of short (up to and including 2 minutes) and medium-length awakenings (2.5 up to and including 4.5 minutes). However, the number of long awakenings (5 minutes or longer) and wake after sleep onset containing only long awakenings was significantly lower for patients with OSA (median: 2 awakenings and 25.5 minutes) compared to patients with COMISA (median: 3 awakenings, P < .01 and 43.3 minutes, P < .001) or with insomnia (median: 3 awakenings, P < .01 and 56.0 minutes, P < .001). Total sleep time was significantly longer and sleep efficiency was significantly higher for the OSA group (median: 418.5 minutes and 84.4%) compared to both the COMISA (median: 391.5 minutes, P < .001 and 77.3%, P < .001) and the insomnia (median: 381.5 minutes, P < .001 and 78.2%, P < .001) groups. The number of sleep-stage transitions during the night for patients with COMISA (median: 194.0) was lower compared to that for patients with OSA (median: 218.0, P < .01) and higher compared to that for patients with insomnia (median: 156.0, P < .001). Other sleep architectural parameters were not discriminative between the groups. CONCLUSIONS: Patients with COMISA show specific characteristics of insomnia, including prolonged awakenings. This variable is distinctive in comparison to patients with OSA. The combination of prolonged awakenings and the presence of sleep-disordered breathing leads to increased sleep disturbance compared to patients having only 1 of the sleep disorders. CITATION: Wulterkens BM, Hermans LWA, Fonseca P, et al. Sleep structure in patients with COMISA compared to OSA and insomnia. J Clin Sleep Med. 2023;19(6):1051-1059.


Subject(s)
Sleep Apnea Syndromes , Sleep Apnea, Obstructive , Sleep Initiation and Maintenance Disorders , Sleep Wake Disorders , Humans , Sleep Initiation and Maintenance Disorders/complications , Sleep Initiation and Maintenance Disorders/epidemiology , Sleep , Sleep Apnea Syndromes/diagnosis , Sleep Apnea, Obstructive/complications , Sleep Apnea, Obstructive/epidemiology , Comorbidity , Sleep Wake Disorders/complications
8.
Bioengineering (Basel) ; 10(1)2023 Jan 12.
Article in English | MEDLINE | ID: mdl-36671681

ABSTRACT

Polysomnography (PSG) remains the gold standard for sleep monitoring but is obtrusive in nature. Advances in camera sensor technology and data analysis techniques enable contactless monitoring of heart rate variability (HRV). In turn, this may allow remote assessment of sleep stages, as different HRV metrics indirectly reflect the expression of sleep stages. We evaluated a camera-based remote photoplethysmography (PPG) setup to perform automated classification of sleep stages in near darkness. Based on the contactless measurement of pulse rate variability, we use a previously developed HRV-based algorithm for 3 and 4-class sleep stage classification. Performance was evaluated on data of 46 healthy participants obtained from simultaneous overnight recording of PSG and camera-based remote PPG. To validate the results and for benchmarking purposes, the same algorithm was used to classify sleep stages based on the corresponding ECG data. Compared to manually scored PSG, the remote PPG-based algorithm achieved moderate agreement on both 3 class (Wake-N1/N2/N3-REM) and 4 class (Wake-N1/N2-N3-REM) classification, with average κ of 0.58 and 0.49 and accuracy of 81% and 68%, respectively. This is in range with other performance metrics reported on sensing technologies for wearable sleep staging, showing the potential of video-based non-contact sleep staging.

9.
Physiol Meas ; 44(1)2023 01 17.
Article in English | MEDLINE | ID: mdl-36595329

ABSTRACT

Objective.The recently-introduced hypnodensity graph provides a probability distribution over sleep stages per data window (i.e. an epoch). This work explored whether this representation reveals continuities that can only be attributed to intra- and inter-rater disagreement of expert scorings, or also to co-occurrence of sleep stage-dependent features within one epoch.Approach.We proposed a simplified model for time series like the ones measured during sleep, and a second model to describe the annotation process by an expert. Generating data according to these models, enabled controlled experiments to investigate the interpretation of the hypnodensity graph. Moreover, the influence of both the supervised training strategy, and the used softmax non-linearity were investigated. Polysomnography recordings of 96 healthy sleepers (of which 11 were used as independent test set), were subsequently used to transfer conclusions to real data.Main results.A hypnodensity graph, predicted by a supervised neural classifier, represents the probability with which the sleep expert(s) assigned a label to an epoch. It thus reflects annotator behavior, and is thereby only indirectly linked to the ratio of sleep stage-dependent features in the epoch. Unsupervised training was shown to result in hypnodensity graph that were slightly less dependent on this annotation process, resulting in, on average, higher-entropy distributions over sleep stages (Hunsupervised= 0.41 versusHsupervised= 0.29). Moreover, pre-softmax predictions were, for both training strategies, found to better reflect the ratio of sleep stage-dependent characteristics in an epoch, as compared to the post-softmax counterparts (i.e. the hypnodensity graph). In real data, this was observed from the linear relation between pre-softmax N3 predictions and the amount of delta power.Significance.This study provides insights in, and proposes new, representations of sleep that may enhance our comprehension about sleep and sleep disorders.


Subject(s)
Sleep Wake Disorders , Sleep , Humans , Polysomnography/methods , Sleep Stages , Time Factors , Electroencephalography
10.
Front Physiol ; 14: 1287342, 2023.
Article in English | MEDLINE | ID: mdl-38250654

ABSTRACT

Introduction: Automated sleep staging using deep learning models typically requires training on hundreds of sleep recordings, and pre-training on public databases is therefore common practice. However, suboptimal sleep stage performance may occur from mismatches between source and target datasets, such as differences in population characteristics (e.g., an unrepresented sleep disorder) or sensors (e.g., alternative channel locations for wearable EEG). Methods: We investigated three strategies for training an automated single-channel EEG sleep stager: pre-training (i.e., training on the original source dataset), training-from-scratch (i.e., training on the new target dataset), and fine-tuning (i.e., training on the original source dataset, fine-tuning on the new target dataset). As source dataset, we used the F3-M2 channel of healthy subjects (N = 94). Performance of the different training strategies was evaluated using Cohen's Kappa (κ) in eight smaller target datasets consisting of healthy subjects (N = 60), patients with obstructive sleep apnea (OSA, N = 60), insomnia (N = 60), and REM sleep behavioral disorder (RBD, N = 22), combined with two EEG channels, F3-M2 and F3-F4. Results: No differences in performance between the training strategies was observed in the age-matched F3-M2 datasets, with an average performance across strategies of κ = .83 in healthy, κ = .77 in insomnia, and κ = .74 in OSA subjects. However, in the RBD set, where data availability was limited, fine-tuning was the preferred method (κ = .67), with an average increase in κ of .15 to pre-training and training-from-scratch. In the presence of channel mismatches, targeted training is required, either through training-from-scratch or fine-tuning, increasing performance with κ = .17 on average. Discussion: We found that, when channel and/or population mismatches cause suboptimal sleep staging performance, a fine-tuning approach can yield similar to superior performance compared to building a model from scratch, while requiring a smaller sample size. In contrast to insomnia and OSA, RBD data contains characteristics, either inherent to the pathology or age-related, which apparently demand targeted training.

11.
Annu Int Conf IEEE Eng Med Biol Soc ; 2022: 2945-2948, 2022 07.
Article in English | MEDLINE | ID: mdl-36086087

ABSTRACT

Nowadays, high amounts of data can be acquired in various applications, spurring the need for interpretable data representations that provide actionable insights. Algorithms that yield such representations ideally require as little a priori knowledge about the data or corresponding annotations as possible. To this end, we here investigate the use of Kohonen's Self-Organizing Map (SOM) in combination with data-driven low-dimensional embeddings obtained through self-supervised Contrastive Predictive Coding. We compare our approach to embeddings found with an auto-encoder and, moreover, investigate three ways to deal with node selection during SOM optimization. As a challenging experiment we analyze nocturnal sleep recordings of healthy subjects, and conclude that - for this noisy real-life data - contrastive learning yields a better low-dimensional embedding for the purpose of SOM training, compared to an auto-encoder. In addition, we show that a stochastic temperature-annealed SOM-training outperforms both a deterministic and a non-temperature-annealed stochastic approach. Clinical relevance - The hypnogram has for decades been the clinical standard in sleep medicine despite the fact that it is a highly simplified representation of a polysomnography recording. We propose a sensor-agnostic algorithm that is able to reveal more intricate patterns in sleep recordings which might teach us about sleep structure and sleep disorders.


Subject(s)
Neural Networks, Computer , Sleep Wake Disorders , Algorithms , Humans , Learning , Sleep
12.
Sleep ; 45(8)2022 08 11.
Article in English | MEDLINE | ID: mdl-35675746

ABSTRACT

Sleep stage classification is an important tool for the diagnosis of sleep disorders. Because sleep staging has such a high impact on clinical outcome, it is important that it is done reliably. However, it is known that uncertainty exists in both expert scorers and automated models. On average, the agreement between human scorers is only 82.6%. In this study, we provide a theoretical framework to facilitate discussion and further analyses of uncertainty in sleep staging. To this end, we introduce two variants of uncertainty, known from statistics and the machine learning community: aleatoric and epistemic uncertainty. We discuss what these types of uncertainties are, why the distinction is useful, where they arise from in sleep staging, and provide recommendations on how this framework can improve sleep staging in the future.


Subject(s)
Sleep Stages , Uncertainty , Humans , Models, Theoretical , Observer Variation
13.
Sleep Med Rev ; 63: 101611, 2022 06.
Article in English | MEDLINE | ID: mdl-35278893

ABSTRACT

Sleep is characterized by an intricate variation of brain activity over time. Measuring these temporal sleep dynamics is relevant for elucidating healthy and pathological sleep mechanisms. The rapidly increasing possibilities for obtaining and processing sleep registrations have led to an abundance of data, which can be challenging to analyze and interpret. This review provides a structured overview of approaches to represent temporal sleep dynamics, categorized based on the way the source data is compressed. For each category of representations, we describe advantages and disadvantages. Standard human-defined 30-s sleep stages have the advantages of standardization and interpretability. Alternative human-defined representations are less standardized but offer a higher temporal resolution (in case of microstructural events such as sleep spindles), or reflect non-categorical information (for example spectral power analysis). Machine-learned representations offer additional possibilities: automated sleep stages are useful for handling large quantities of data, while alternative sleep stages obtained from clustering data-driven features could aid finding new patterns and new possible clinical interpretations. While newly developed sleep representations may offer relevant insights, they can be difficult to interpret in for example a clinical context. Therefore, there should always be a balance between developing these sophisticated sleep analysis techniques and maintaining clinical explainability.


Subject(s)
Electroencephalography , Sleep , Electroencephalography/methods , Humans , Learning , Polysomnography/methods , Sleep Stages
14.
J Clin Sleep Med ; 18(4): 1135-1143, 2022 04 01.
Article in English | MEDLINE | ID: mdl-34913868

ABSTRACT

STUDY OBJECTIVES: We created a Dutch version of the Paris Arousal Disorders Severity Scale (PADSS), which assesses non-rapid eye movement (NREM) parasomnia symptoms over the past year (PADSS-year). This questionnaire was previously validated in patients with sleep walking and/or sleep terrors (SW/ST). We validated the questionnaire in SW/ST patients, and in a broader population, including patients with confusional arousals, comorbidities, and medication users ("other NREM parasomnias"). Furthermore, we introduced a version covering the past month (PADSS-month), with the potential purpose of evaluating symptom evolution and treatment response. METHODS: We compared PADSS scores among 54 SW/ST patients, 34 age-matched controls, and 23 patients with other NREM parasomnias. We evaluated discriminative capacity, internal consistency, and construct validity. Furthermore, we assessed the test-retest reliability and treatment response of PADSS-month. RESULTS: Healthy controls scored significantly lower than both patient groups. We found an excellent diagnostic accuracy (area under the curve PADSS-year 0.990, PADSS-month 0.987) and an acceptable internal consistency. Exploratory factor analysis identified 3 components: "behaviors outside the bed," "behaviors in/around the bed," and "violent behaviors," with the former 2 factors reflecting the distinction between SW and ST. PADSS-month showed an acceptable test-retest reliability (0.75). Additionally, PADSS-month significantly decreased after pharmaceutical and/or behavioral treatment. This change was correlated with the clinical impression of the caregiver, implying that PADSS-month is sensitive to treatment effects. CONCLUSIONS: The Dutch PADSS questionnaire can be used as a screening tool in a broad population of patients with NREM parasomnia, not only SW/ST. Furthermore, we validated a PADSS-month version to assess the evolution of symptoms and treatment effect. CITATION: van Mierlo P, Hermans L, Arnulf I, Pijpers A, Overeem S, van Gilst M. Validation of the Dutch translation of the Paris Arousal Disorders Severity Scale for non-REM parasomnias in a 1-year and 1-month version. J Clin Sleep Med. 2022;18(4):1135-1143.


Subject(s)
Night Terrors , Parasomnias , Surveys and Questionnaires , Arousal , Humans , Netherlands , Night Terrors/diagnosis , Parasomnias/diagnosis , Reproducibility of Results , Translations
15.
BMC Res Notes ; 14(1): 329, 2021 Aug 26.
Article in English | MEDLINE | ID: mdl-34446098

ABSTRACT

OBJECTIVE: Parkinson's disease is a common, age-related, neurodegenerative disease, affecting gait and other motor functions. Technological developments in consumer imaging are starting to provide high-quality, affordable tools for home-based diagnosis and monitoring. This pilot study aims to investigate whether a consumer depth camera can capture changes in gait features of Parkinson's patients. The dataset consisted of 19 patients (tested in both a practically defined OFF phase and ON phase) and 8 controls, who performed the "Timed-Up-and-Go" test multiple times while being recorded with the Microsoft Kinect V2 sensor. Camera-derived features were step length, average walking speed and mediolateral sway. Motor signs were assessed clinically using the Movement Disorder Society Unified Parkinson's Disease Rating Scale. RESULTS: We found significant group differences between patients and controls for step length and average walking speed, showing the ability to detect Parkinson's features. However, there were no differences between the ON and OFF medication state, so further developments are needed to allow for detection of small intra-individual changes in symptom severity.


Subject(s)
Gait Disorders, Neurologic , Neurodegenerative Diseases , Parkinson Disease , Gait , Humans , Parkinson Disease/diagnosis , Pilot Projects , Walking Speed
16.
Nat Sci Sleep ; 13: 885-897, 2021.
Article in English | MEDLINE | ID: mdl-34234595

ABSTRACT

PURPOSE: There is great interest in unobtrusive long-term sleep measurements using wearable devices based on reflective photoplethysmography (PPG). Unfortunately, consumer devices are not validated in patient populations and therefore not suitable for clinical use. Several sleep staging algorithms have been developed and validated based on ECG-signals. However, translation from these techniques to data derived by wearable PPG is not trivial, and requires the differences between sensing modalities to be integrated in the algorithm, or having the model trained directly with data obtained with the target sensor. Either way, validation of PPG-based sleep staging algorithms requires a large dataset containing both gold standard measurements and PPG-sensor in the applicable clinical population. Here, we take these important steps towards unobtrusive, long-term sleep monitoring. METHODS: We developed and trained an algorithm based on wrist-worn PPG and accelerometry. The method was validated against reference polysomnography in an independent clinical population comprising 244 adults and 48 children (age: 3 to 82 years) with a wide variety of sleep disorders. RESULTS: The classifier achieved substantial agreement on four-class sleep staging with an average Cohen's kappa of 0.62 and accuracy of 76.4%. For children/adolescents, it achieved even higher agreement with an average kappa of 0.66 and accuracy of 77.9%. Performance was significantly higher in non-REM parasomnias (kappa = 0.69, accuracy = 80.1%) and significantly lower in REM parasomnias (kappa = 0.55, accuracy = 72.3%). A weak correlation was found between age and kappa (ρ = -0.30, p<0.001) and age and accuracy (ρ = -0.22, p<0.001). CONCLUSION: This study shows the feasibility of automatic wearable sleep staging in patients with a broad variety of sleep disorders and a wide age range. Results demonstrate the potential for ambulatory long-term monitoring of clinical populations, which may improve diagnosis, estimation of severity and follow up in both sleep medicine and research.

17.
Nat Sci Sleep ; 13: 349-360, 2021.
Article in English | MEDLINE | ID: mdl-33737849

ABSTRACT

INTRODUCTION: Assessing objective measures of sleep fragmentation could yield important features reflecting impaired sleep quality in people with insomnia. Survival analysis allows the specific examination of the stability of NREM sleep, REM sleep and wake. The objective of this study was to assess the differences between survival dynamics of NREM sleep, REM sleep and wake between people with insomnia and healthy controls. METHODS: We analyzed retrospective polysomnography recordings from 86 people with insomnia and 94 healthy controls. For each participant, survival dynamics of REM sleep, NREM sleep and wake were represented using Weibull distributions. We used lasso penalized parameter selection in combination with linear regression to analyze the difference between participant groups with respect to the Weibull scale and shape parameters, while correcting for age, sex, total sleep time and relevant interaction effects. RESULTS: Significant effects of group were found for the NREM scale parameter, and for the wake scale and shape parameters. Results indicated that people with insomnia had less stable NREM sleep and more stable wake after sleep onset compared to healthy controls. Additionally, the altered distribution of wake segment lengths indicated an increased difficulty to fall asleep after longer awakenings in the insomnia group. However, these differences were mainly observed in younger participants. Significant effects of group for the survival parameters of REM sleep were not found. CONCLUSION: As illustrated by our results, survival analysis can be very useful for disentangling different types of sleep fragmentation in people with insomnia. For instance, the current findings suggest that people with insomnia have an increased fragmentation of NREM sleep, but not necessarily of REM sleep. Additional research into the underlying mechanisms of NREM sleep fragmentation could possibly lead to a better understanding of impaired sleep quality in people with insomnia, and consequently to improved treatment.

18.
IEEE J Biomed Health Inform ; 25(5): 1409-1418, 2021 05.
Article in English | MEDLINE | ID: mdl-33338025

ABSTRACT

Polysomnography (PSG) is the current gold standard for the diagnosis of sleep disorders. However, this multi-parametric sleep monitoring tool also has some drawbacks, e.g. it limits the patient's mobility during the night and it requires the patient to come to a specialized sleep clinic or hospital to attach the sensors. Unobtrusive techniques for the detection of sleep disorders such as sleep apnea are therefore gaining increasing interest. Remote photoplethysmography using video is a technique which enables contactless detection of hemodynamic information. Promising results in near-infrared have been reported for the monitoring of sleep-relevant physiological parameters pulse rate, respiration and blood oxygen saturation. In this study we validate a contactless monitoring system on eight patients with a high likelihood of relevant obstructive sleep apnea, which are enrolled for a sleep study at a specialized sleep center. The dataset includes 46.5 hours of video recordings, full polysomnography and metadata. The camera can detect pulse and respiratory rate within 2 beats/breaths per minute accuracy 92% and 91% of the time, respectively. Estimated blood oxygen values are within 4 percentage points of the finger-oximeter 89% of the time. These results demonstrate the potential of a camera as a convenient diagnostic tool for sleep apnea, and sleep disorders in general.


Subject(s)
Oximetry , Polysomnography , Sleep , Humans , Proof of Concept Study , Respiratory Rate , Vital Signs
19.
Psychopharmacology (Berl) ; 238(1): 83-94, 2021 Jan.
Article in English | MEDLINE | ID: mdl-32939597

ABSTRACT

RATIONALE: The mechanisms underlying impaired sleep quality in insomnia are not fully known, but an important role for sleep fragmentation has been proposed. OBJECTIVES: The aim of this study is to explore potential mechanisms of sleep fragmentation influencing alterations of perceived sleep quality. METHODS: We analyzed polysomnography (PSG) recordings from a double-blind crossover study with zopiclone 7.5 mg and placebo, in elderly participants with insomnia complaints and age-matched healthy controls. We compared survival dynamics of sleep and wake across group and treatment. Subsequently, we used a previously proposed model to estimate the amount of sleep onset latency (SOL) misperception from PSG-defined sleep fragmentation. Self-reported and model-estimated amount of SOL misperception were compared across group and treatment, as well as model prediction errors. RESULTS: In the zopiclone night, the average segment length of NREM sleep was increased (group F = 1.16, p = 0.32; treatment F = 8.89, p < 0.01; group x treatment F = 0.44, p = 0.65), while the segment length of wake was decreased (group F = 1.48, p = 0.23; treatment F = 11.49, p < 0.01; group x treatment F = 0.36, p = 0.70). The self-reported and model-estimated amount of SOL misperception were lower during the zopiclone night (self-reported group F = 6.08, p < 0.01, treatment F = 10.8, p < 0.01, group x treatment F = 2.49, p = 0.09; model-estimated F = 1.70, p = 0.19, treatment F = 16.1, p < 0.001, group x treatment F = 0.60, p = 0.55). The prediction error was not altered (group F = 1.62, p = 0.20; treatment F = 0.20, p = 0.65; group x treatment F = 1.01, p = 0.37). CONCLUSIONS: Impaired subjective sleep quality is associated with decreased NREM stability, together with increased stability of wake. Furthermore, we conclude that zopiclone-induced changes in SOL misperception can be largely attributed to predictable changes of sleep architecture.


Subject(s)
Azabicyclo Compounds/therapeutic use , Piperazines/therapeutic use , Sleep Initiation and Maintenance Disorders/drug therapy , Sleep, REM/drug effects , Adult , Aged , Azabicyclo Compounds/administration & dosage , Clinical Trials as Topic , Cross-Over Studies , Double-Blind Method , Female , Humans , Male , Middle Aged , Piperazines/administration & dosage , Polysomnography , Self Report , Sleep Deprivation/prevention & control
SELECTION OF CITATIONS
SEARCH DETAIL
...