Macromol Biosci ; 20(7): e2000024, 2020 07.
Article in English | MEDLINE | ID: mdl-32558365

ABSTRACT

For in situ tissue engineering (TE) applications it is important that implant degradation proceeds in concord with neo-tissue formation to avoid graft failure. It will therefore be valuable to have an imaging contrast agent (CA) available that can report on the degrading implant. For this purpose, a biodegradable radiopaque biomaterial is presented, modularly composed of a bisurea chain-extended polycaprolactone (PCL2000-U4U) elastomer and a novel iodinated bisurea-modified CA additive (I-U4U). Supramolecular hydrogen bonding interactions between the components ensure their intimate mixing. Porous implant TE-grafts are prepared by simply electrospinning a solution containing PCL2000-U4U and I-U4U. Rats receive an aortic interposition graft, either composed of only PCL2000-U4U (control) or of PCL2000-U4U and I-U4U (test). The grafts are explanted for analysis at three time points over a 1-month period. Computed tomography imaging of the test group implants prior to explantation shows a decrease in iodide volume and density over time. Explant analysis also indicates scaffold degradation. (Immuno)histochemistry shows comparable cellular contents and a similar neo-tissue formation process for test and control group, demonstrating that the CA does not have apparent adverse effects. A supramolecular approach to create solid radiopaque biomaterials can therefore be used to noninvasively monitor the biodegradation of synthetic implants.


Subject(s)
Biocompatible Materials/chemistry , Blood Vessel Prosthesis , Contrast Media/chemistry , Tissue Engineering , 3T3 Cells , Animals , Cell Survival , Contrast Media/chemical synthesis , Elastomers/chemistry , Fibroblasts/cytology , Male , Mice , Molecular Weight , Polyesters/chemistry , Rats, Sprague-Dawley , Tissue Scaffolds/chemistry , Tomography, X-Ray Computed
4.
J Cardiovasc Comput Tomogr ; 10(5): 398-406, 2016.
Article in English | MEDLINE | ID: mdl-27452311

ABSTRACT

BACKGROUND: In patients with suspected prosthetic heart valve (PHV) dysfunction, routine evaluation echocardiography and fluoroscopy may provide unsatisfactory results for identifying the cause of dysfunction. This study assessed the value of MDCT as a routine, complementary imaging modality in suspected PHV-dysfunction for diagnosing the cause of PHV dysfunction and proposing a treatment strategy. METHODS: Patients with suspected PHV dysfunction were prospectively recruited. All patients underwent routine diagnostic work-up (TTE, TEE ± fluoroscopy) and additional MDCT imaging. An expert panel reviewed all cases and assessed the diagnosis and treatment strategy, first based on routine evaluation only, second with additional MDCT information. RESULTS: Forty-two patients were included with suspected PHV obstruction (n = 30) and PHV regurgitation (n = 12). The addition of MDCT showed incremental value to routine evaluation in 26/30 (87%) cases for detecting the specific cause of PHV obstruction and in 7/12 (58%) regurgitation cases for assessment of complications and surgical planning. The addition of MDCT resulted in treatment strategy change in 8/30 (27%) patients with suspected obstruction and 3/12 (25%) patients with regurgitation. CONCLUSION: In addition to echocardiography and fluoroscopy, MDCT may identify the cause of PHV dysfunction and alter the treatment strategy.


Subject(s)
Aortic Valve/surgery , Heart Valve Prosthesis Implantation/instrumentation , Heart Valve Prosthesis , Mitral Valve/surgery , Multidetector Computed Tomography , Prosthesis Failure , Adult , Aged , Aortic Valve/diagnostic imaging , Aortic Valve/physiopathology , Cardiac-Gated Imaging Techniques , Cross-Sectional Studies , Echocardiography, Doppler, Color , Electrocardiography , Female , Heart Valve Prosthesis Implantation/adverse effects , Hemodynamics , Humans , Male , Middle Aged , Mitral Valve/diagnostic imaging , Mitral Valve/physiopathology , Netherlands , Predictive Value of Tests , Prospective Studies , Reoperation , Risk Factors , Treatment Outcome
5.
Eur Radiol ; 26(4): 997-1006, 2016 Apr.
Article in English | MEDLINE | ID: mdl-26474984

ABSTRACT

OBJECTIVES: Recent studies have proposed additional multidetector-row CT (MDCT) for prosthetic heart valve (PHV) dysfunction. References to discriminate physiological from pathological conditions early after implantation are lacking. We present baseline MDCT findings of PHVs 6 weeks post implantation. METHODS: Patients were prospectively enrolled and TTE was performed according to clinical guidelines. 256-MDCT images were systematically assessed for leaflet excursions, image quality, valve-related artefacts, and pathological and additional findings. RESULTS: Forty-six patients were included comprising 33 mechanical and 16 biological PHVs. Overall, MDCT image quality was good and relevant regions remained reliably assessable despite mild-moderate PHV-artefacts. MDCT detected three unexpected valve-related pathology cases: (1) prominent subprosthetic tissue, (2) pseudoaneurysm and (3) extensive pseudoaneurysms and valve dehiscence. The latter patient required valve surgery to be redone. TTE only showed trace periprosthetic regurgitation, and no abnormalities in the other cases. Additional findings were: tilted aortic PHV position (n = 3), pericardial haematoma (n = 3) and pericardial effusion (n = 3). Periaortic induration was present in 33/40 (83 %) aortic valve patients. CONCLUSIONS: MDCT allowed evaluation of relevant PHV regions in all valves, revealed baseline postsurgical findings and, despite normal TTE findings, detected three cases of unexpected, clinically relevant pathology. KEY POINTS: • Postoperative MDCT presents baseline morphology relevant for prosthetic valve follow-up. • 83 % of patients show periaortic induration 6 weeks after aortic valve replacement. • MDCT detected three cases of clinically relevant pathology not found with TTE. • Valve dehiscence detection by MDCT required redo valve surgery in one patient. • MDCT is a suitable and complementary imaging tool for follow-up purposes.


Subject(s)
Aortic Valve Insufficiency/surgery , Prosthesis Failure/adverse effects , Adult , Aged , Aortic Valve/diagnostic imaging , Aortic Valve Insufficiency/diagnostic imaging , Echocardiography , Female , Follow-Up Studies , Heart Valve Prosthesis , Heart Valve Prosthesis Implantation/methods , Humans , Male , Middle Aged , Multidetector Computed Tomography/methods , Postoperative Care/methods , Prospective Studies , Recurrence , Reference Standards
6.
Circ Cardiovasc Imaging ; 8(9): e003703, 2015 Sep.
Article in English | MEDLINE | ID: mdl-26353926

ABSTRACT

Echocardiography and fluoroscopy are the main techniques for prosthetic heart valve (PHV) evaluation, but because of specific limitations they may not identify the morphological substrate or the extent of PHV pathology. Cardiac computed tomography (CT) and magnetic resonance imaging (MRI) have emerged as new potential imaging modalities for valve prostheses. We present an overview of the possibilities and pitfalls of CT and MRI for PHV assessment based on a systematic literature review of all experimental and patient studies. For this, a comprehensive systematic search was performed in PubMed and Embase on March 24, 2015, containing CT/MRI and PHV synonyms. Our final selection yielded 82 articles on surgical valves. CT allowed adequate assessment of most modern PHVs and complemented echocardiography in detecting the obstruction cause (pannus or thrombus), bioprosthesis calcifications, and endocarditis extent (valve dehiscence and pseudoaneurysms). No clear advantage over echocardiography was found for the detection of vegetations or periprosthetic regurgitation. Whereas MRI metal artifacts may preclude direct prosthesis analysis, MRI provided information on PHV-related flow patterns and velocities. MRI demonstrated abnormal asymmetrical flow patterns in PHV obstruction and allowed prosthetic regurgitation assessment. Hence, CT shows great clinical relevance as a complementary imaging tool for the diagnostic work-up of patients with suspected PHV obstruction and endocarditis. MRI shows potential for functional PHV assessment although more studies are required to provide diagnostic reference values to allow discrimination of normal from pathological conditions.


Subject(s)
Echocardiography , Heart Valve Diseases/surgery , Heart Valve Prosthesis , Magnetic Resonance Imaging, Cine , Multimodal Imaging/methods , Tomography, X-Ray Computed , Heart Valve Diseases/diagnosis , Heart Valves/diagnostic imaging , Heart Valves/pathology , Humans
7.
Tissue Eng Part A ; 21(19-20): 2583-94, 2015 Oct.
Article in English | MEDLINE | ID: mdl-26200255

ABSTRACT

Inflammation is a natural phase of the wound healing response, which can be harnessed for the in situ tissue engineering of small-diameter blood vessels using instructive, bioresorbable synthetic grafts. This process is dependent on colonization of the graft by host circulating cells and subsequent matrix formation. Typically, vascular regeneration in small animals is governed by transanastomotic cell ingrowth. However, this process is very rare in humans and hence less relevant for clinical translation. Therefore, a novel rat model was developed, in which cell ingrowth from the adjacent tissue is inhibited using Gore-Tex sheathing. Using this model, our aim here was to prove that functional blood vessels can be formed in situ through the host inflammatory response, specifically by blood-borne cells. The model was validated by implanting sex-mismatched aortic segments on either anastomoses of an electrospun poly(ɛ-caprolactone) (PCL) graft, filled with fibrin gel, into the rat abdominal aorta. Fluorescent in situ hybridization analysis revealed that after 1 and 3 months in vivo, over 90% of infiltrating cells originated from the bloodstream, confirming the effective shielding of transanastomotic cell ingrowth. Using the validated model, PCL/fibrin grafts were implanted, either or not loaded with monocyte chemotactic protein-1 (MCP-1), and cell infiltration and tissue development were investigated at various key time points in the healing cascade. A phased healing response was observed, initiated by a rapid influx of inflammatory cells, mediated by the local release of MCP-1. After 3 months in vivo, the grafts consisted of a medial layer with smooth muscle cells in an oriented collagen matrix, an intimal layer with elastin fibers, and confluent endothelium. This study proves the regenerative potential of cells in the circulatory system in the setting of in situ vascular tissue engineering.


Subject(s)
Tissue Engineering/methods , Animals , Blood Vessel Prosthesis , Chemokine CCL2/metabolism , Immunohistochemistry , In Situ Hybridization, Fluorescence , Male , Myocytes, Smooth Muscle/cytology , Polyesters/chemistry , Rats , Rats, Sprague-Dawley , Tissue Scaffolds/chemistry
8.
Am J Cardiol ; 116(1): 112-20, 2015 Jul 01.
Article in English | MEDLINE | ID: mdl-25935442

ABSTRACT

The implanted prosthetic heart valve (PHV) size is vital for the evaluation of suspected PHV dysfunction and in case of reoperation or valve-in-valve transcatheter approaches. The labeled size is not always known, and discrepancies exist between manufacturers' labeled sizes and true sizes. Reproducible methods for noninvasive PHV size assessment are lacking. We determined the reliability and agreement of PHV size measurements using multidetector-row computed tomography (MDCT) and provide reference values of MDCT measurements compared with manufacturer specifications. In vitro, 15 different PHV types in available sizes (total n = 63) were imaged. In vivo, available MDCT acquisitions of patients with PHVs were retrospectively gathered in 2 centers, and 230 patients with 249 PHVs were included. Inner valve area and area-derived diameter were measured in all PHVs. For mechanical PHVs, the inner diameter was also measured. Data were analyzed using the intraclass correlation coefficient and Bland-Altman plots and related to manufacturer specifications. Measurements could be obtained for all PHV types, except the Björk-Shiley (n = 7) because of severe valve-related artifacts hampering the image quality. Intrarater and interrater reliability was excellent for biological and mechanical PHVs (intraclass correlation coefficients ≥0.903). Agreement was good for all measurements with an overall maximal mean difference (95% confidence interval) of -2.61 mm(2) (-37.9 to 32.7), -0.1 mm (-1.1 to 1.0), and 0 mm (-0.4 to 0.3) for valve area, area-derived diameter, and inner diameter, respectively. MDCT reliably discriminated consecutive PHV sizes as labeled by the manufacturer because the absolute ranges for the measurements never overlapped. In conclusion, MDCT allows assessment of the implanted PHV size with excellent reliability and agreement and can discriminate between PHV sizes for contemporary prostheses. MDCT can be used to noninvasively identify the manufacturer-labeled PHV size.


Subject(s)
Heart Valve Prosthesis Implantation , Heart Valve Prosthesis , Multidetector Computed Tomography , Humans , Netherlands , Prosthesis Design , Reference Values , Reproducibility of Results , Retrospective Studies
9.
J Cardiothorac Vasc Anesth ; 29(3): 632-6, 2015.
Article in English | MEDLINE | ID: mdl-25817849

ABSTRACT

OBJECTIVE: Using magnetic resonance imaging, the authors studied the influence of a single high dose of intraoperative dexamethasone on the severity of cerebral edema that can occur early after coronary artery bypass grafting (CABG). It was hypothesized that high-dose intraoperative dexamethasone reduces cerebral edema after CABG. DESIGN: Secondary analysis in a subset of participants of the Dexamethasone for Cardiac Surgery (DECS) trial. The DECS trial was a multicenter, randomized, double-blind, placebo-controlled trial in 4,494 cardiac surgery patients, which studied the effect of high-dose dexamethasone on mortality and major complications after cardiac surgery. SETTING: A large university hospital in The Netherlands. PARTICIPANTS: Twenty adult patients who underwent CABG with cardiopulmonary bypass (CPB) between March and November 2011. INTERVENTIONS: Participants received a single intravenous dose of dexamethasone, 1 mg/kg, or placebo, at induction of anesthesia. MEASUREMENTS AND MAIN RESULTS: Patients underwent magnetic resonance imaging scanning immediately after surgery. The primary outcome was the severity of cerebral edema. Data from 18 patients (9 in each group, median age 69 years in both groups) could be analyzed. Patients in the dexamethasone group were (median, interquartile range 66 (53-99) minutes on cardiopulmonary bypass v 95 (81-105) minutes in the placebo group (p = 0.11). Only 1 patient in the dexamethasone group had slight cerebral edema (0% v 11%, p = 1.00), and edema severity did not differ between groups (p = 1.00). CONCLUSIONS: Relevant degrees of early postoperative cerebral edema were not observed. The present study findings strongly contrasted with older studies showing cerebral edema early after CABG in most patients.


Subject(s)
Brain Edema/diagnosis , Brain Edema/epidemiology , Coronary Artery Bypass/trends , Postoperative Complications/diagnosis , Postoperative Complications/epidemiology , Aged , Anti-Inflammatory Agents/administration & dosage , Brain Edema/prevention & control , Coronary Artery Bypass/adverse effects , Dexamethasone/administration & dosage , Double-Blind Method , Female , Humans , Incidence , Male , Middle Aged , Postoperative Complications/prevention & control
10.
Am J Cardiol ; 115(5): 670-5, 2015 Mar 01.
Article in English | MEDLINE | ID: mdl-25591899

ABSTRACT

Severely symptomatic patients with obstructive hypertrophic cardiomyopathy (HC) may benefit from surgical myectomy. In patients with enlarged mitral leaflets and mitral regurgitation, myectomy can be combined with anterior mitral leaflet extension (AMLE) to stiffen the midsegment of the leaflet. The aim of this study was to evaluate the long-term results of myectomy combined with AMLE in patients with obstructive HC. This prospective, observational, single-center cohort study included 98 patients (49 ± 14 years, 37% female) who underwent myectomy combined with AMLE from 1991 to 2012. End points included all-cause mortality and change in clinical and echocardiographic characteristics. Mortality was compared with age- and gender-matched patients with nonobstructive HC and subjects from the general population. Long-term follow-up was 8.3 ± 6.1 years. There was no operative mortality, and New York Heart Association class was reduced from 2.8 ± 0.5 to 1.3 ± 0.5 (p <0.001), left ventricular outflow tract gradient from 93 ± 25 to 9 ± 8 mm Hg (p <0.001), mitral valve regurgitation from grade 2.0 ± 0.9 to 0.5 ± 0.8 (p <0.001), and systolic anterior motion of the mitral valve from grade 2.4 ± 0.9 to 0.1 ± 0.3 (p <0.001). The 1-, 5-, 10-, and 15-year cumulative survival rates were 98%, 92%, 86%, and 83%, respectively, and did not differ from the general population (99%, 97%, 92%, and 85%, respectively, p = 0.3) or patients with nonobstructive HC (98%, 97%, 88%, and 83%, respectively, p = 0.8). In conclusion, in selected patients with obstructive HC, myectomy combined with AMLE is a low-risk surgical procedure. It results in long-term symptom relief and survival similar to the general population.


Subject(s)
Cardiomyopathy, Hypertrophic/mortality , Cardiomyopathy, Hypertrophic/surgery , Mitral Valve/surgery , Adult , Aged , Cardiomyopathy, Hypertrophic/complications , Cohort Studies , Female , Humans , Male , Middle Aged , Mitral Valve Insufficiency/complications , Mitral Valve Insufficiency/mortality , Mitral Valve Insufficiency/surgery , Survival Rate , Time Factors , Treatment Outcome
11.
Eur Radiol ; 25(6): 1623-30, 2015 Jun.
Article in English | MEDLINE | ID: mdl-25501272

ABSTRACT

OBJECTIVES: Retrospective ECG-gated multidetector-row computed tomography (MDCT) is increasingly used for the assessment of prosthetic heart valve (PHV) dysfunction, but is also hampered by PHV-related artefacts/cardiac arrhythmias. Furthermore, it is performed without nitroglycerine or heart rate correction. The purpose was to determine whether MDCT performed before potential redo-PHV surgery is feasible for concomitant coronary artery stenosis assessment and can replace invasive coronary angiography (CAG). METHODS: PHV patients with CAG and MDCT were identified. Based on medical history, two groups were created: (I) patients with no known coronary artery disease (CAD), (II) patients with known CAD. All images were scored for the presence of significant (>50 %) stenosis. CAG was the reference test. RESULTS: Fifty-one patients were included. In group I (n = 38), MDCT accurately ruled out significant stenosis in 19/38 (50 %) patients, but could not replace CAG in the remaining 19/38 (50 %) patients due to non-diagnostic image quality (n = 16) or significant stenosis (n = 3) detection. In group II (n = 13), MDCT correctly found no patients without significant stenosis, requiring CAG imaging in all. MDCT assessed patency in 16/19 (84 %) grafts and detected a hostile anatomy in two. CONCLUSION: MDCT performed for PHV dysfunction assessment can replace CAG (100 % accurate) in approximately half of patients without previously known CAD. KEY POINTS: • Retrospective MDCT is increasingly used for prosthetic heart valve dysfunction assessment • In case of PHV reoperation, invasive coronary angiography is also required • MDCT can replace CAG in 50 % of patients without coronary artery disease • When conclusive for coronary assessment, MDCT stenosis rule out is highly accurate • Replacing CAG saves associated risks of distant embolization of thrombi or vegetations.


Subject(s)
Coronary Angiography/methods , Equipment Failure Analysis/methods , Heart Valve Prosthesis , Heart Valves/diagnostic imaging , Multidetector Computed Tomography/methods , Preoperative Care/methods , Aged , Coronary Stenosis/diagnostic imaging , Female , Humans , Male , Middle Aged , Prosthesis Failure , Reoperation , Reproducibility of Results
12.
Echocardiography ; 32(1): 114-25, 2015 Jan.
Article in English | MEDLINE | ID: mdl-24724568

ABSTRACT

BACKGROUND: Two-dimensional transthoracic and transesophageal echocardiography (2DTTE and 2DTEE) may fail to detect signs of prosthetic heart valve (PHV) endocarditis due to acoustic shadowing. Three-dimensional (3D) TEE may have additional value; however, data are scarce. This study was performed to investigate the additional value of 3DTEE for the detection of aortic PHV endocarditis and the extent of the disease process. METHODS: Retrospective analysis of complex aortic PHV endocarditis cases that underwent 2DTTE, 2DTEE, and 3DTEE before surgery. Echocardiograms were individually assessed by 2 cardiologists blinded for the outcome. Surgical and pathological inspection served as the reference standard for vegetations and peri-annular extensions (abscesses/mycotic aneurysms). To determine if the proximal coronary arteries were involved in the inflammatory process as well, computed tomography angiography findings were added to reference standard. RESULTS: Fifteen aortic PHV endocarditis cases were identified. According to the reference standard, all 15 cases had peri-annular extensions, 13 of which had a close relationship with the proximal right and/or left coronary artery. In 6 of 15 patients, a vegetation was present. Combined 2DTTE/TEE missed 1/6 vegetations and 1/15 peri-annular extensions. After addition of 3DTEE, all vegetations (6/6) and peri-annular extensions (15/15) were detected, without adding false positives. Compared to 2DTEE, in 3/15 cases, 3DTEE resulted in better delineation of the anatomical relationship of the proximal coronary arteries to the peri-annular extensions. As a result, 3DTEE had an additional value in 5/15 cases. CONCLUSION: In complex aortic, PHV endocarditis 3DTEE may have additional value compared to 2D echocardiography.


Subject(s)
Aortic Valve/diagnostic imaging , Endocarditis/diagnostic imaging , Endocarditis/etiology , Heart Valve Prosthesis/adverse effects , Prosthesis-Related Infections/diagnostic imaging , Prosthesis-Related Infections/etiology , Aged , Aortic Valve/surgery , Echocardiography, Three-Dimensional/methods , Echocardiography, Transesophageal/methods , Female , Humans , Male , Middle Aged , Reproducibility of Results , Retrospective Studies , Sensitivity and Specificity
13.
J Vis Exp ; (93): e52127, 2014 Nov 24.
Article in English | MEDLINE | ID: mdl-25490000

ABSTRACT

To simplify and facilitate beating heart (i.e., off-pump), minimally invasive coronary artery bypass surgery, a new coronary anastomotic connector, the Trinity Clip, is developed based on the excimer laser-assisted nonocclusive anastomosis technique. The Trinity Clip connector enables simplified, sutureless, and nonocclusive connection of the graft to the coronary artery, and an excimer laser catheter laser-punches the opening of the anastomosis. Consequently, owing to the complete nonocclusive anastomosis construction, coronary conditioning (i.e., occluding or shunting) is not necessary, in contrast to the conventional anastomotic technique, hence simplifying the off-pump bypass procedure. Prior to clinical application in coronary artery bypass grafting, the safety and quality of this novel connector will be evaluated in a long-term experimental porcine off-pump coronary artery bypass (OPCAB) study. In this paper, we describe how to evaluate the coronary anastomosis in the porcine OPCAB model using various techniques to assess its quality. Representative results are summarized and visually demonstrated.


Subject(s)
Anastomosis, Surgical/instrumentation , Coronary Artery Bypass, Off-Pump/instrumentation , Laser Therapy/instrumentation , Anastomosis, Surgical/methods , Animals , Coronary Artery Bypass, Off-Pump/methods , Coronary Vessels/surgery , Equipment Design , Female , Laser Therapy/methods , Models, Animal , Swine
14.
Innovations (Phila) ; 9(2): 130-6; discussion 136, 2014.
Article in English | MEDLINE | ID: mdl-24758949

ABSTRACT

OBJECTIVE: This pilot study evaluates the anastomotic healing of the Excimer Laser Assisted Nonocclusive Anastomosis coronary connector at 6 months in a porcine off-pump coronary artery bypass (OPCAB) model. METHODS: Left internal thoracic artery to left anterior descending coronary artery bypass in two animals and left internal thoracic artery to left anterior descending coronary artery and right internal thoracic artery to right coronary artery bypasses in one animal were evaluated intraoperatively and at 6 months. The anastomoses (n = 4) were examined by angiography, intravascular ultrasound, optical coherence tomography, scanning electron microscopy, and histology. RESULTS: At follow-up, all anastomoses (n = 4) were fully patent (FitzGibbon grade A). Scanning electron microscopy demonstrated complete endothelial coverage of the anastomotic surface, and histology showed minimal streamlining intimal hyperplasia. The in vivo intravascular ultrasound and optical coherence tomography acquisitions confirmed histologic findings. Optical coherence tomography demonstrated 0.06-mm intimal coverage of the intraluminal part of the connector along the full circumference of the anastomosis. CONCLUSIONS: In this pilot study, the Excimer Laser Assisted Nonocclusive Anastomosis coronary connector showed an excellent healing response on the long-term in the porcine OPCAB model. Hence, this new concept might be a potential alternative to hand-sutured anastomosis in (minimally invasive) OPCAB surgery.


Subject(s)
Coronary Artery Bypass, Off-Pump/methods , Coronary Artery Disease/surgery , Coronary Vessels/surgery , Thoracic Arteries/surgery , Wound Healing , Anastomosis, Surgical/instrumentation , Animals , Coronary Angiography , Coronary Artery Disease/diagnosis , Coronary Vessels/diagnostic imaging , Coronary Vessels/pathology , Disease Models, Animal , Male , Microscopy, Electron, Scanning , Swine , Thoracic Arteries/diagnostic imaging , Thoracic Arteries/pathology , Tomography, Optical Coherence , Ultrasonography, Interventional
15.
Atherosclerosis ; 233(1): 242-7, 2014 Mar.
Article in English | MEDLINE | ID: mdl-24529151

ABSTRACT

OBJECTIVE: Perivascular adipose tissue (pvAT) may induce a local pro-inflammatory environment, possibly contributing to coronary atherosclerosis. We investigated whether there is a difference in adipocytokine production by pvAT near stenotic and non-stenotic coronary artery segments in patients with coronary artery disease (CAD). METHODS: In patients undergoing CABG with or without valve replacement (n = 38) pvAT near stenotic and near non-stenotic coronary segments was harvested. PvAT was incubated ex vivo for 24h. Concentrations of 23 adipocytokines were measured in the supernatants with a Multiplex assay. The number of macrophages (CD68, CD11c, CD206) and lymphocytes (CD45) in pvAT was determined. Differences between stenosis and control pvAT were tested with Wilcoxon signed rank test corrected for multiple comparisons. RESULTS: Production of IL-5, IL-1α, IL-17, IL-18 and IL-23 was higher in control than stenosis pvAT samples (p < 0.0021). Macrophages were more abundant in stenosis than in control pvAT (median n/400× field: 2.3 IQR: 0.3-4.5 versus 1.2 IQR: 0.1-2.5). There was a predominance of M2 macrophages in both stenosis and control pvAT (median n/400× field: macrophages stenosis: M1: 0.0; M2: 1.0 p = 0.004; control: M1: 0.0; M2: 0.6 p = 0.013). The relation between adipocytokine production and macrophage infiltration was not different in stenosis and control pvAT. CONCLUSION: In patients with CAD, multiple adipocytokines were secreted at higher levels by pvAT near non-stenotic than near stenotic coronary artery segments. Furthermore, pvAT macrophages are associated with stenosis of the adjacent vessel. M2 macrophages were more abundant than M1 macrophages in pvAT.


Subject(s)
Adipokines/metabolism , Adipose Tissue/metabolism , Coronary Artery Disease/physiopathology , Coronary Stenosis/physiopathology , Macrophages/physiology , Aged , Aged, 80 and over , Coronary Artery Bypass , Coronary Vessels , Female , Humans , Interleukin-17/biosynthesis , Interleukin-18/biosynthesis , Interleukin-1alpha/biosynthesis , Interleukin-23/biosynthesis , Interleukin-5/biosynthesis , Male , Middle Aged
16.
Eur J Cardiothorac Surg ; 46(3): 386-97; discussion 397, 2014 Sep.
Article in English | MEDLINE | ID: mdl-24554075

ABSTRACT

OBJECTIVES: The aim was to describe procedural volumes, patient risk profile and outcomes of heart valve surgery in the past 16 years in Netherlands. METHODS: The Dutch National Database for Cardio-Thoracic Surgery includes approximately 200 000 cardiac operations performed between 1995 and 2010. Information on all valve surgeries (56 397 operations) was extracted. We determined trends for changes in procedural volume, demographics, risk profile and in-hospital mortality of valve operations. Because of incomplete data in the first years of registration, the total number of operations in those years was estimated using Poisson regression. For a subset from 2007 to 2010, follow-up data were available. Survival status was obtained through linkage with the national Cause of Death Registry, and survival analysis was performed using Kaplan-Meier method. Information on discharge and readmissions was obtained from the National Hospital Discharge Registry. RESULTS: The annual volume of heart valve operations increased by more than 100% from an estimated 2431 in 1995 to 5906 in 2010. Adjusted for population size in Netherlands, the number of operations per 100 000 adults increased from 20 in 1995 to 43 in 2010. In 2010, frequently performed valve surgery included the following: 34.6% isolated aortic valve (AoV) replacement, 21.8% AoV replacement and coronary artery bypass grafting (CABG), 14.6% isolated mitral valve surgery (repair or replacement) and 9.1% mitral valve and CABG. In AoV surgery, an increasing use of bioprostheses in all age categories is observed. In mitral valve surgery, 75.4% was performed by repair rather than replacement in 2010. In-hospital mortality for all valve surgery decreased significantly from 4.6% in 2007 to 3.6% in 2010, whereas the mean logistic EuroSCORE remained stable (median 5.8, P = 1.000). Thirty-day mortality after all valve surgery was 3.9% and 120-day mortality was 6.5%. At 1 year, survival after all valve surgery was 91.6% and a reoperation had been performed in 1.6%. The median postoperative length of stay was 7 days (interquartile range (IQR) 5-11) in the primary hospital and 11 days (IQR 8-16), including subsequent stay, in the secondary hospital. CONCLUSIONS: The results of this study provide a comprehensive overview of valve surgery trends and outcomes in Netherlands. The number of heart valve operations performed in Netherlands has increased since 1995. The significant decrease in mortality and unchanged EuroSCORE between 2007 and 2010 might reflect a general improvement of the safety of valve surgery.


Subject(s)
Heart Valve Prosthesis Implantation/methods , Heart Valves/surgery , Adolescent , Adult , Aged , Aged, 80 and over , Databases, Factual , Female , Heart Valve Diseases/surgery , Heart Valve Prosthesis Implantation/mortality , Humans , Kaplan-Meier Estimate , Male , Middle Aged , Netherlands/epidemiology , Treatment Outcome , Young Adult
17.
J Thorac Cardiovasc Surg ; 147(4): 1390-1397.e2, 2014 Apr.
Article in English | MEDLINE | ID: mdl-23993317

ABSTRACT

OBJECTIVES: To facilitate minimally invasive coronary artery bypass grafting, a simplified alternative for hand-sutured anastomoses must be developed. We assessed the feasibility and anastomotic healing of the ameliorated Excimer laser-assisted nonocclusive anastomosis coronary prototype connector in an acute rabbit study (study 1) and in a long-term porcine off-pump coronary bypass study (study 2). METHODS: Eighteen anastomoses were constructed on the abdominal aorta of the rabbit. In the porcine model, 15 left internal thoracic artery to left anterior descending coronary artery bypasses were evaluated intraoperatively and at 4 hours, 4 and 10 days, 2, 3, and 5 weeks, and 6 months (each n = 2 anastomoses). The anastomoses were examined by angiography, flow measurements, fractional flow reserve, coronary flow reserve, histologic features, and scanning electron microscopy. RESULTS: In study 1, all 18 anastomoses were patent and resisted supraphysiologic pressures (n = 12, 300 mm Hg). In study 2, the connector enabled nonocclusive and fast (7.7 ± 2.2 minutes, mean ± standard deviation) anastomosis construction. All but 1 of 15 anastomoses (owing to a technical error) were fully patent (FitzGibbon grade A) at follow-up. Histologic examination and scanning electron microscopy demonstrated complete endothelialization of the anastomoses at 10 days. At 6 months, no flow-limiting but streamline-covering intimal hyperplasia was shown (fractional flow reserve, 0.93 ± 0.07 mean ± standard deviation). CONCLUSIONS: The new nonocclusive coronary connector is easy to use, and the long-term results suggest favorable healing and remodeling in the porcine model. After downsizing, this anastomotic device, with its emphasis on zero ischemia and simplified prebounding of vessel walls, has intrinsic potential for minimally invasive off-pump coronary artery bypass surgery.


Subject(s)
Aorta, Abdominal/surgery , Coronary Artery Bypass, Off-Pump , Laser Therapy/instrumentation , Lasers, Excimer , Anastomosis, Surgical/instrumentation , Animals , Equipment Design , Feasibility Studies , Female , Models, Animal , Rabbits , Swine
18.
Int J Cardiovasc Imaging ; 30(2): 377-87, 2014 Feb.
Article in English | MEDLINE | ID: mdl-24293045

ABSTRACT

Echocardiography may miss prosthetic heart valve (PHV) endocarditis which advocates for novel imaging techniques to improve diagnostic accuracy and patient outcome. The purpose of this study was to determine the complementary diagnostic value of cardiac computed tomography angiography (CTA) to the clinical routine workup including transthoracic and transesophageal echocardiography (TTE/TEE) in patients with suspected PHV endocarditis and its impact on patient treatment. A diagnostic prospective cross-sectional study was chosen as design. Besides clinical routine workup (including TTE/TEE), CTA was performed to assess its diagnostic accuracy and complementary diagnostic/therapeutic value. For the diagnostic accuracy, the reference standard was surgical findings or clinical follow-up. To determine the complementary diagnostic/therapeutic value an expert-panel was used as reference standard. Twenty-eight patients were included. CTA resulted in a major diagnostic change in six patients (21 %) mainly driven by novel detection of mycotic aneurysms by CTA. Furthermore, treatment changes occurred in seven patients (25 %) compared to clinical routine workup. Diagnostic accuracy of routine clinical workup plus CTA was superior to clinical routine workup alone for the detection of PHV endocarditis in general, vegetations and peri-annular extension. This study demonstrates that CTA and clinical workup including TTE and TEE are complementary in patients with PHV endocarditis. Therefore, CTA imaging has to be considered after clinical routine workup in patients with a high suspicion on PHV endocarditis.


Subject(s)
Coronary Angiography/methods , Endocarditis, Bacterial/diagnostic imaging , Heart Valve Prosthesis Implantation/adverse effects , Heart Valve Prosthesis Implantation/instrumentation , Heart Valve Prosthesis/adverse effects , Multidetector Computed Tomography , Prosthesis-Related Infections/diagnostic imaging , Aged , Cross-Sectional Studies , Echocardiography, Doppler, Color , Echocardiography, Transesophageal , Endocarditis, Bacterial/microbiology , Endocarditis, Bacterial/therapy , Female , Humans , Male , Middle Aged , Predictive Value of Tests , Prognosis , Prospective Studies , Prosthesis-Related Infections/microbiology , Prosthesis-Related Infections/therapy
20.
Ann Thorac Surg ; 96(4): 1478-1480, 2013 Oct.
Article in English | MEDLINE | ID: mdl-24088468

ABSTRACT

A giant left atrial appendage is a rare congenital anomaly that has been reported on only a few occasions. We report two symptomatic patients with atrial fibrillation combined with a cerebellar infarct in one and dyspnea in the other. Both patients were treated surgically with resection of the giant left atrial appendage and radiofrequency pulmonary vein isolation. Recognition of this uncommon pathology can lead to timely surgical intervention.


Subject(s)
Atrial Appendage/abnormalities , Adult , Aged , Atrial Appendage/pathology , Atrial Appendage/surgery , Humans , Male